Baixe o app para aproveitar ainda mais
Prévia do material em texto
Integrating Siemens Drive into Rockwell Automations Studio 5000 using Free Telegram for Distributed Drives G110M and G120D Application Manual Studio 5000 free Telegram https://support.industry.siemens.com/cs/ww/en/view/82843076 Siemens Industry Online Support https://support.industry.siemens.com/cs/ww/en/view/82843076 Legal information Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 2 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Legal information Use of application examples Application examples illustrate the solution of automation tasks through an interaction of several components in the form of text, graphics and/or software modules. The application examples are a free service by Siemens AG and/or a subsidiary of Siemens AG (“Siemens”). They are non- binding and make no claim to completeness or functionality regarding configuration and equipment. The application examples merely offer help with typical tasks; they do not constitute customer-specific solutions. You yourself are responsible for the proper and safe operation of the products in accordance with applicable regulations and must also check the function of the respective application example and customize it for your system. Siemens grants you the non-exclusive, non-sublicensable and non-transferable right to have the application examples used by technically trained personnel. Any change to the application examples is your responsibility. Sharing the application examples with third parties or copying the application examples or excerpts thereof is permitted only in combination with your own products. The application examples are not required to undergo the customary tests and quality inspections of a chargeable product; they may have functional and performance defects as well as errors. It is your responsibility to use them in such a manner that any malfunctions that may occur do not result in property damage or injury to persons. Disclaimer of liability Siemens shall not assume any liability, for any legal reason whatsoever, including, without limitation, liability for the usability, availability, completeness and freedom from defects of the application examples as well as for related information, configuration and performance data and any damage caused thereby. This shall not apply in cases of mandatory liability, for example under the German Product Liability Act, or in cases of intent, gross negligence, or culpable loss of life, bodily injury or damage to health, non-compliance with a guarantee, fraudulent non-disclosure of a defect, or culpable breach of material contractual obligations. Claims for damages arising from a breach of material contractual obligations shall however be limited to the foreseeable damage typical of the type of agreement, unless liability arises from intent or gross negligence or is based on loss of life, bodily injury or damage to health. The foregoing provisions do not imply any change in the burden of proof to your detriment. You shall indemnify Siemens against existing or future claims of third parties in this connection except where Siemens is mandatorily liable. By using the application examples you acknowledge that Siemens cannot be held liable for any damage beyond the liability provisions described. Other information Siemens reserves the right to make changes to the application examples at any time without notice. In case of discrepancies between the suggestions in the application examples and other Siemens publications such as catalogs, the content of the other documentation shall have precedence. The Siemens terms of use (https://support.industry.siemens.com) shall also apply. Security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks. Such systems, machines and components should only be connected to an enterprise network or the Internet if and to the extent such a connection is necessary and only when appropriate security measures (e.g. firewalls and/or network segmentation) are in place. For additional information on industrial security measures that may be implemented, please visit https://www.siemens.com/industrialsecurity. Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed at: https://www.siemens.com/industrialsecurity. https://support.industry.siemens.com/ https://www.siemens.com/industrialsecurity https://www.siemens.com/industrialsecurity List of contents Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 3 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d List of contents Legal information ......................................................................................................... 2 1 Overview ............................................................................................................. 4 2 Telegram ............................................................................................................. 5 3 Reference Scaling Parameters ......................................................................... 9 4 Startdrive Configuration ................................................................................. 10 5 Download to the drive ..................................................................................... 28 6 Motor Identification ......................................................................................... 30 7 Create New Project with Rockwell Software Studio 5000 ........................... 36 8 Rockwell Automation EDS Wizard ................................................................. 41 9 Add a Siemens Drive to the Ethernet Network ............................................. 49 10 Import Add-On Instruction .............................................................................. 53 11 Configure IP Address for a Rockwell Controller .......................................... 55 12 Configure RSLinx Communications for a Rockwell Controller .................. 61 13 Insert a Rung for the Add-On Instruction ...................................................... 65 14 Controlling the Siemens Drive ....................................................................... 70 15 Download Project to the Rockwell Controller .............................................. 73 16 Create a Rockwell’s FactoryTalk View Application ...................................... 75 17 Establish Communications Between the Rockwell Controller and the Rockwell PanelView Plus Terminal ................................................................ 76 18 Import Siemens Global Objects ..................................................................... 79 19 Import Siemens Display .................................................................................. 84 20 Add GOTO Button to a Display ...................................................................... 89 21 Alarms and Warnings ......................................................................................94 22 Edit Tags for Alarm Setup............................................................................... 98 23 Test Application ............................................................................................. 100 24 Transfer Utility ............................................................................................... 108 25 Firmware Upgrade Wizard ............................................................................ 111 26 Appendix ........................................................................................................ 116 26.1 Application Support .......................................................................... 116 26.2 Links and Literature .......................................................................... 116 26.3 History .............................................................................................. 116 1 Overview Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 4 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 1 Overview Scope: This document will explain how to integrate Siemens drives into Rockwell Automations Studio 5000 software. This document is intended for individuals with Rockwell Automation Studio 5000, FactoryTalk View Machine Edition, and commissioning a Siemens drive. This document will illustrate how to add Electronic Data Sheet (EDS) file, add a Siemens drive to the Ethernet/IP network, import Add-On Instructions, and create a routine for the Add-On instruction to an existing Studio 5000 PLC program. This document will illustrate how to import global objects, displays, alarms, and warnings into a FactoryTalk View Machine Edition HMI application. Components Used: Hardware: Rockwell Automations CompactLogix 5370 Controller 1769-L16ER-BB1B Siemens G120 CU250S-2 PN V4.7 SP10 Software: Rockwell Automations Studio 5000 V30 and FactoryTalk View Studio Machine Edition V10.0 Startdrive V16.1 2 Telegram Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 5 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 2 Telegram What is a Telegram? Telegrams are universal blocks of data that organize parameters and functions into a uniform consistent format that all Siemens drives can use to pass data to the PLC. They are organized into 16-bit process words (abbreviated as PZD) that contain relevant information such as control words, status words, and setpoints. Most telegrams have a control word, status word, speed setpoint, and speed feedback word in common. A telegram is easily selected within the programming platform by loading the correct electronic data sheet (EDS) file. This is a custom telegram that provides feedback for the status, actual speed, actual current, actual torque, alarm code, warning code, and digital inputs to the drive (Proximity Switch, Photo eye, etc.). Table 2-1 From Drive to PLC PLC Tagname Description Data Type Drive Parameter DriveStatus0 Status Word 1 (ZSW1) INT r52 DriveStatus1 Smoothed Actual Speed (NIST_A_GLATT) INT r63[1] DriveStatus2 Smoothed Actual Current (IAIST_GLATT) INT r68[1] DriveStatus3 Smoothed Actual Torque (MIST_GLATT) INT r80[1] DriveStatus4 Alarm Code - The most recent alarm code is displayed. 0 = No alarm present. (WARN_CODE) INT p2132 DriveStatus5 Fault Code - The oldest fault code is displayed. 0 = No fault present. (ALARM_CODE) INT p2131 DriveStatus6 Digital Input Status INT p722 DriveStatus7 Digital Input Status INT p722 2 Telegram Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 6 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Table 2-2 From PLC to Drive PLC Tagname Description Data Type Drive Parameter DriveControl0 Control Word 1 (STW1) INT r54 DriveControl1 Speed Setpoint (NSOLL_A) INT p1070[0] Data from the Drive to the PLC – Drive Status Word Individual Bits: Table 2-3 Status Word 1 (ZSW1) Bit Name Functionality Data Type Drive Parameter 0 Ready To Power On 1 = Drive ready 0 = Drive not ready Bool r0899.0 1 Ready To Run 1 = Ready to run 0 = Not ready to run Bool r0899.1 2 Drive Running 1 = Motor enabled 0 = Motor not enabled Bool r0899.2 3 Fault Present 1 = Converter fault 0 = No fault active Bool r2139.3 4 Coast Stop 0 = Coast down (OFF2) inactive 1 = Coast down active Bool r0899.4 5 Quick Stop 0 = Quick stop (OFF3) inactive 1 = Quick stop active Bool r0899.5 6 Switch On Inhibited 1 = Motor inhibited from switching on 0 = Motor can be switched on Bool r0899.6 7 Warning Present 1 = Warning present 0 = No warning present Bool r2139.7 8 Motor At Acceptable Speed 1 = Speed deviation within tolerance 0 = Speed deviation outside tolerance Bool r2197.7 9 PLC Has Control 1 = Master control requested 0 = No action Bool r0899.9 10 Speed Comparison Reached 1 = Speed greater than or equal to max speed 0 = Speed less than max speed Bool r2199.1 11 Torque Limit Reached 1 = Torque limit reached 0 = Torque limit not reached Bool r0052.11 12 Holding Brake Open 1 = Holding brake open 0 = Holding brake closed Bool r0899.12 13 Motor Overload 0 = No overtemperature alarm 1 = Overtemperature alarm present Bool r2135.14 14 Reverse Direction 1 = Motor rotates clockwise 0 = Motor rotates counterclockwise Bool r2197.3 15 Drive Overload 0 = No converter thermal overload alarm 1 = Thermal overload alarm present Bool r2135.15 Table 2-4 Digital Input Status Bit Name Functionality Data Type Drive Parameter 0 DI0 1 = On; 0 = Off BOOL 1 DI1 1 = On; 0 = Off BOOL 2 Telegram Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 7 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Bit Name Functionality Data Type Drive Parameter 2 DI2 1 = On; 0 = Off BOOL 3 DI3 1 = On; 0 = Off BOOL 4 DI4 1 = On; 0 = Off BOOL 5 DI5 1 = On; 0 = Off BOOL 6 DI6 1 = On; 0 = Off BOOL 7 Reserved 8 Reserved 9 Reserved 10 Reserved 11 DI11 1 = On; 0 = Off BOOL 12 DI12 1 = On; 0 = Off BOOL 13 Reserved 14 Reserved 15 Reserved 16 DI16 1 = On; 0 = Off BOOL 17 DI17 1 = On; 0 = Off BOOL 18 DI18 1 = On; 0 = Off BOOL 19 DI19 1 = On; 0 = Off BOOL 20 Reserved 21 Reserved 22 Reserved 23 Reserved 24 DIDO24 1 = On; 0 = Off BOOL 25 DIDO25 1 = On; 0 = Off BOOL 26 DIDO26 1 = On; 0 = Off BOOL 27 DIDO27 1 = On; 0 = Off BOOL 28 Reserved 29 Reserved 30 Reserved 31 Reserved Data from the PLC to the Drive – Drive Control Word Individual Bits: Table 2-5 Control Word 1 (STW1) Bit Name Functionality Data Type Drive Parameter 0 Run Command 1 = Enable drive 0 = Ramp down and disable drive Bool p0840[0] 1 Coast Stop 0 = No stop command issued 1 = Immediate disable and coast to stop Bool p0844[0] 2 Quick Stop 0 = No stop command issued 1 = Immediate disable and quick stop Bool p0848[0] 3 Enable Operation 1 = Enable drive (pulses enabled) 0 = Inverter prohibited from generating pulses Bool p0852[0] 4 RFG Enable 1 = Ramp function generator output enabled Bool p1140[0] 2 Telegram Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 8 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Bit Name Functionality Data Type Drive Parameter 0 = Ramp function generator output set to 0 5 RFG Freeze 1 = Ramp function generator follows setpoint input 0 = Ramp functiongenerator freezes at current value Bool p1141[0] 6 Setpoint Enable 1 = Ramp function generator setpoint input enabled 0 = Ramp function generator input set to 0 Bool p1142[0] 7 Fault Acknowledge 1 = Acknowledge faults (on rising edge) Bool p2103[0] 8 Reserved 9 Reserved 10 PLC Control 1 = Control is by PLC 0 = No control by PLC Bool p0854[0] 11 Reverse Direction 1 = Reverse Rotation 0 = Forward Rotation Bool p1113[0] 12 Reserved 13 MOP Raise Setpoint 1 = Raise Motorized potentiometer setpoint 0 = No action Bool p1035[0] 14 MOP Lower Setpoint 1 = Lower Motorized potentiometer setpoint 0 = No action Bool p1036[0] 15 Reserved 3 Reference Scaling Parameters Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 9 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 3 Reference Scaling Parameters Certain data words are normalized internally by the drive using the following parameters. Commanded values use the scale that is set by these parameters. For example, if the desired 100% command to motor speed is 2000 rpm, then p2000 should be set to 2000. A command of 1500 rpm would be treated as 75%. Table 3-1 Reference Scaling Parameters Parameter Name [Data Type] Functionality p2000 Reference Speed, Velocity, or Frequency [FloatingPoint32] The value of this parameter corresponds to 100% or 4000 hex (16b) or 4000000 hex (32b) of speed, velocity, or frequency. Factory default values: 120.00 m/min (velocity), 3000.00 rpm (speed), 50.00 Hz (frequency) p2001 Reference Voltage [FloatingPoint32] The value of this parameter corresponds to 100% or 4000 hex (16b) or 4000000 hex (32b) of voltage. Factory default value: 1000 V p2002 Reference Current or Pressure [FloatingPoint32] The value of this parameter corresponds to 100% or 4000 hex (16b) or 4000000 hex (32b) of current or pressure. Factory default values: 100.00 Arms (current), 100.00 bar (pressure) p2003 Reference Force or Torque [FloatingPoint32] The value of this parameter corresponds to 100% or 4000 hex (16b) or 4000000 hex (32b) of force or torque. Factory default values: 100.00 N (force), 1.00 Nm (torque) p2004 Reference Power [FloatingPoint32] The value of this parameter corresponds to 100% or 4000 hex (16b) or 4000000 hex (32b) of power. Its factory default is calculated from p2003 * p2000 (torque * speed) or p2003 * p2000 (force * linear speed). p2005 Reference Angle [FloatingPoint32] The value of this parameter corresponds to 100% or 4000 hex (16b) or 4000000 hex (32b) of ref. angle. Factory default values: 90.00 degrees p2006 Reference Temperature [FloatingPoint32] The value of this parameter corresponds to 100% or 4000 hex (16b) or 4000000 hex (32b) of temperature. Factory default values: 100.00 degrees C p2007 Reference Acceleration [FloatingPoint32] The value of this parameter corresponds to 100% or 4000 hex (16b) or 4000000 hex (32b) of rotational acceleration. Factory default values: 0.01 revolutions/sec^2 4 Startdrive Configuration Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 10 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 4 Startdrive Configuration Create a New Project: Launch TIA Portal or Startdrive. For this example, TIA Portal is being used. Create New Project. Assign Project Name. Select Path. Click Create. Click Open the project view. Online Access: Click the Accessible devices from the toolbar. Type of the PG/PC interface: Select the appropriate interface for your application from the pulldown. For this example, PN/IE will be used. PG/PC interface: Select the appropriate interface for the application from the pulldown. For this example, Intel® I210 Gigabit Network Connection will be used. Select the appropriate drive. Click Start search. Click Show. 4 Startdrive Configuration Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 11 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d The result will be displayed. Assign IP address: Double click Online & Diagnostics. Expand Functions. Click Assign IP address. Enter IP address. Enter Subnet mask. Click Assign IP address. 4 Startdrive Configuration Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 12 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Upload device as new station: Right click the desired drive. Click Upload device as new station. An image of the result is below. 4 Startdrive Configuration Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 13 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Commission the Drive: Expand the desired drive from the Project tree. Double click Commissioning. Click Commissioning Wizard. Application class: You can set the application class in the wizard function in the configuration. Select one of the following classes: Standard Drive Control: The same performance such as U/f with FCC and slip compensation / speed accuracy is only restricted. There is therefore no speed controller and no torque 4 Startdrive Configuration Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 14 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d accuracy. Two rating plate parameters are required for the motor commissioning: Rated current and rated speed. The synchronous rated speed is accepted. The motor data identification is preset. A short measurement is performed once (only stator resistance, dead time compensation) to improve the start-up. This is followed by a direct switchover to operation. The optimization of the speed controller is not relevant. Dynamic Drive Control: Compared to Standard Drive Control, the performance such as sensorless vector control / speed accuracy is significantly improved. The robustness is improved with higher model change limits but takes effect at slow reversing. Three rating plate parameters are required for the motor commissioning: Rated current, rated power and rated speed. The motor data identification is preset and serves to simplify and shorten the measurement compared with the existing standstill measurement. This is followed by a direct switchover to operation. In the speed controller optimization, there is a shorter measurement of the moment of inertia / magnetizing current with direct transition to operation and the setpoint speed defined by the user. Expert: The Expert functions include the Standard Drive Control and Dynamic Drive Control functions. Select the appropriate application class for the drive from the pulldown. For this example, [1] Standard Drive Control (SDC) is selected. Click Next. 4 Startdrive Configuration Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 15 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Setpoint specification: Selection if the drive is connected to a PLC and where the setpoint is to be created. Select the appropriate controller connection and the setpoint specification. For this example, data exchange from the PLC to the drive (Ramp function in the drive) will be used. Click Next. Further functions: Select Free function blocks. Click Next. 4 Startdrive Configuration Integrating Siemens Drive into Rockwell Automations Studio 5000 EntryID: 82843076, V2.0.1, 10/2020 16 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Defaults of the setpoints/command sources: Selection of a predefined interconnection of the inputs/outputs and, if required, the fieldbus telegram. Can be changed later user- specifically. Select the appropriate IO configuration from the pulldown. For this example, [4] Conveyor technology with fieldbus will be selected. Select the appropriate Telegram configuration from the pulldown. For this example, temporarily select [352] SIEMENS telegram 352, PZD-6/6. PZD-6/6 represents the number of Integers that will be received from the drive and sent to the drive. Click Next. 4 Startdrive Configuration Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 17 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Drive setting: Selection of motor standard and load cycle. Select appropriate setting from the pull down. Enter Drive unit line supply voltage. For this example, the motor being used is [0] IEC-Motor (50 Hz, SI unitts) at 230V line supply voltage. Click Next. 4 Startdrive Configuration Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 18 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Drive options: Configuration of optional braking resistor and drive filter. If applicable, select Braking resistor. Select Drive filter type motor side from pull down. For this example, braking resistor will be deselected with [0] No filter. Click Next. 4 Startdrive Configuration Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 19 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Motor: Specification of motor type and motor data. Select appropriate motor configuration from the pull down. For this example, Enter motor data is selected. Select motor type from the pulldown. For this example, [1] Induction motor is selected. Select the connection type for the motor from the pulldown. For this example, Star is selected. Enter the rated motor current, rated motor power, rated motor speed, rated motor voltage, and rated motor frequency from the motor nameplate. Select motor cooling type from the pulldown. For this example, [0] Natural ventilization is selected. Select Temperature sensor from the pulldown. For this example, [0] No sensor is selected. Click Next. 4 Startdrive Configuration Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 20 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Motor holding brake: Select Motor holding brake configuration from pull down. For this example, [0] No motor holding brake available. Click Next. 4 Startdrive Configuration Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 21 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Important parameters: Specification of the most important dynamic response data. Synchronization of the speed of the drive with the speed of the PLC: Enter Reference speed: p2000. Sets reference quantity for speed and frequency. Enter Maximum speed: p1082[0]. Sets the highest possible speed. Configuration of ramp up and ramp down time: Enter Ramp up time: p1120[0]. The ramp-function generator ramps-up the speed setpoint from standstill (setpoint = 0) up to the maximum speed (p1082) in this time. Enter OFF1 ramp down time: p1121[0]. The ramp-function generator ramps-down the speed setpoint from the maximum speed (p1082) down to standstill (setpoint = 0) in this time. Enter OFF3 (quick stop) ramp down time: Sets the ramp-down time from the maximum speed down to zero speed for the OFF3 command. Configuration of the current limit: Enter current limit: p640[0]. Sets the current limit. Click Next. 4 Startdrive Configuration Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 22 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Drive functions: Specification of the method to measure the motor data. Select technological application (Standard Drive Control) from the pulldown. For this example, [0] Constant load (linear characteristic) is selected. Select motor identification from the pulldown. For this example, [2] Identifying motor data (at standstill) is selected. Click Next. 4 Startdrive Configuration Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 23 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Summary: Click Finish. 4 Startdrive Configuration Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 24 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Change telegram selection to a free telegram: Double click Parameter. Expand Communication. Click Transmit direction. Click Telegram configuration. 4 Startdrive Configuration Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 25 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Expand PROFINET interface [X150]. Click Telegram configuration. Select Free telegram from the pulldown. Change the length for the Send (Actual value) to 8. Change the length for the Receive (setpoint) to 2. Deselect Hide inactive interconnections. Click PZD 7&8. 4 Startdrive Configuration Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 26 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Expand BICO. Scroll to r722. Click r722. Click OK. 4 Startdrive Configuration Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 27 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Select Hide inactive interconnections. A snapshot of the result appears below. 5 Download to the drive Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 28 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 5 Download to the drive Expand the desired drive from the Project tree. Select the appropriate drive. Click download from the toolbar. Click Load. 5 Download to the drive Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 29 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 6 Motor Identification Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 30 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 6 Motor Identification Expand the desired drive from the Project tree. Select the appropriate drive. Double click Commissioning. Click Control panel. Click Go online from the toolbar. Notice the motor measurement drive status is visible. Click Activate. 6 Motor Identification Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 31 © S ie m e n s A G 2 0 2 0 A ll rig h ts r e s e rv e d Click Accept. If required, set Drive enables. Click Forward. Repeat until motor measurement drive status is invisible. Notice the motor measurement drive status is invisible. Click Deactivate. 6 Motor Identification Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 32 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Click Accept. Field bus interface protocol selection: Double click Parameter. 6 Motor Identification Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 33 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Click Parameter View. Scroll down to p2030. Select [10] Ethernet/IP from the pulldown. User Defined Parameter List: Click create new user defined parameter list. Type the following parameters: 922, 2030, 8980, 2000, 2001, 2002, 2003, 2004, 1820. These are a few useful parameters. Click Save. 6 Motor Identification Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 34 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Click Yes. Assign a file name and location. Click Save. Save RAM to ROM: Double click Commissioning. Click Backup/Restore. Save RAM data to EEPROM: Click Save. 6 Motor Identification Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 35 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Save project: Click Save project. Click Go offline: Reboot drive. 7 Create New Project with Rockwell Software Studio 5000 Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 36 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 7 Create New Project with Rockwell Software Studio 5000 Under Create, Click New Project. Expand appropriate controller. Select controller. Assign name. Click Browse. 7 Create New Project with Rockwell Software Studio 5000 Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 37 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Select appropriate folder. Click OK. 7 Create New Project with Rockwell Software Studio 5000 Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 38 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Click Next. 7 Create New Project with Rockwell Software Studio 5000 Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 39 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Select revision from pulldown. If applicable, select expansion IO from pulldown. Click Finish. 7 Create New Project with Rockwell Software Studio 5000 Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 40 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 8 Rockwell Automation EDS Wizard Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 41 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 8 Rockwell Automation EDS Wizard A Siemens drive is not firmware dependent to operate. These EDS files were created without a specific firmware version. From the Toolbar, Click Tools. Click EDS Hardware Installation Tool. Welcome to Rockwell Automation’s EDS Wizard. To continue, Click Next. 8 Rockwell Automation EDS Wizard Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 42 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Options - What task do you want to complete? Select Register an EDS file(s). This option will add a device(s) to our database. To continue, Click Next. Registration – Electronic Data Sheet file(s) will be added to your system for use in Rockwell Automation applications. Select Register a directory of EDS files and check Look in subfolders. Click Browse. 8 Rockwell Automation EDS Wizard Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 43 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Browse to the folder where the EDS files are located. Select All EDS Files (this is the folder where all EDS files for a Siemens G drive resides) folder. Click OK. 8 Rockwell Automation EDS Wizard Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 44 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Click Next. 8 Rockwell Automation EDS Wizard Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 45 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d EDS File Installation Test Results – This test evaluates each EDS file for errors in the EDS file. This test does not guarantee EDS file validity. If the installation test results have a green check mark, click Next. 8 Rockwell Automation EDS Wizard Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 46 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Change Graphic Image – You can change the graphic image that is associated with a device. To continue, click Next. 8 Rockwell Automation EDS Wizard Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 47 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Final Task Summary – This is a review of the task you want to complete. You would like to register the following device. To continue, click Next. You have successfully completed the EDS Wizard. To continue, click Finish. 8 Rockwell Automation EDS Wizard Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 48 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 9 Add a Siemens Drive to the Ethernet Network Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 49 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 9 Add a Siemens Drive to the Ethernet Network In the Controller Organizer, expand I/O Configuration, right click on Ethernet and click New Module. In the “Select Module Type” window, type IO Monitor into the search bar. The results should show Siemens G Drive – IO Monitor. Another option would be to deselect Module Type Vendor Filters and scroll down to Siemens AG, select Siemens AG. Select Siemens G Drive – IO Monitor. Select Close on Create. To continue, click Create. 9 Add a Siemens Drive to the Ethernet Network Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 50 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Assign a Name for the New Module. Assign the IP Address. Click Change.Select Disable Keying in the Electronic Keying Dropdown. Select the connections size data type as INT. Click OK. 9 Add a Siemens Drive to the Ethernet Network Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 51 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Change module definition? Click Yes. Click OK. 9 Add a Siemens Drive to the Ethernet Network Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 52 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d You have completed adding an Ethernet module to control a Siemens drive by using a Free telegram. 10 Import Add-On Instruction Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 53 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 10 Import Add-On Instruction Right click on Add-On Instruction and click Import Add-On Instruction. Browse to the folder where the Add-On Instruction resides. Select AOI_IO_Monitor_HMI.L5X for use with an HMI. Click Open. Click OK. 10 Import Add-On Instruction Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 54 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d You have completed importing the Add-On Instruction. 11 Configure IP Address for a Rockwell Controller Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 55 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 11 Configure IP Address for a Rockwell Controller Connect the Ethernet cable directly to the controller. If the process is not connected to the plant Ethernet communications, connect the PC and the controller Ethernet cable to an ethernet switch. Record the MAC address of the controller. Launch BootP DHCP Tool. Select the proper Ethernet adapter through which the PC is connected to the PLC. Click OK. 11 Configure IP Address for a Rockwell Controller Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 56 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Click OK. Click OK. 11 Configure IP Address for a Rockwell Controller Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 57 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Click Add Relation. The software will begin pinging the controller. 11 Configure IP Address for a Rockwell Controller Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 58 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Double click the MAC address. Assign the Client IP Address. Click OK. Select the device. Click Enable BOOTP/DHCP. 11 Configure IP Address for a Rockwell Controller Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 59 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d The device appears in the upper section. Select the device in the lower section. Click Disable BOOTP/DHCP. The IP address has been successfully assigned to the controller. Close software. 11 Configure IP Address for a Rockwell Controller Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 60 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 12 Configure RSLinx Communications for a Rockwell Controller Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 61 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 12 Configure RSLinx Communications for a Rockwell Controller Launch RSLinx Classic. Click Communications. Click Configure Drivers. Select Ethernet/IP Driver from the pulldown. Click Add New. 12 Configure RSLinx Communications for a Rockwell Controller Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 62 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Assign a name for the driver. Select the appropriate IP address. Click Apply. Click OK. 12 Configure RSLinx Communications for a Rockwell Controller Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 63 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Click Close. Click Communications. Click RSWho. 12 Configure RSLinx Communications for a Rockwell Controller Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 64 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Expand the newly created driver. The PC is communicating with the processor. 13 Insert a Rung for the Add-On Instruction Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 65 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 13 Insert a Rung for the Add-On Instruction Click Add-On. Click AOI_IO_Monitor_HMI. Right click AOI_IO_Monitor_HMI. Click New Tag. 13 Insert a Rung for the Add-On Instruction Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 66 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Assign Name. Click Create. 13 Insert a Rung for the Add-On Instruction Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 67 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Double click DriveStatus (data from the drive to the PLC). Click pulldown. Expand Drive_01:I (Drive_01 was the name assigned to the drive when it was added to the IO Configuration). Double click Drive_01:I.Data. Press Enter. 13 Insert a Rung for the Add-On Instruction Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 68 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Click pulldown for DriveControl (data from the PLC to the drive). Expand Drive_01:O (Drive_01 was the name assigned to the drive when it was added to the IO Configuration). Double click Drive_01:O.Data. Press Enter. The next fields in the AOI can be assigned with an Integer value. Reference_Speed_P2000 = p2000 (Reference speed reference frequency) Reference_Current_P2002 = p2002 (Reference current) Reference_Torque_P2003 = p2003 (Reference torque) The units for actual speed is RPM. A conversion would be required to display the actual speed in a different unit. 13 Insert a Rung for the Add-On Instruction Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 69 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 14 Controlling the Siemens Drive Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 70 ©S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 14 Controlling the Siemens Drive As an example, a Siemens drive will be replacing a Rockwell’s PowerFlex 525 drive. Output structure for Rockwell’s PowerFlex 525 drive. Output structure for a Siemens drive using Telegram 352. To Run or Jog the Drive in the Forward direction: DriveControl1_MainSetpoint (RPM): Enter a value from (–) Maximum speed to (+) Maximum speed DriveControl0_DriveEnable = 1 DriveControl0_ReverseDirection = 0 DriveControl0_RunCommand = 1 14 Controlling the Siemens Drive Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 71 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d To Run or Jog the Drive in the Reverse Direction: DriveControl1_MainSetpoint (RPM): Enter a value from (–) Maximum speed to (+) Maximum speed DriveControl0_DriveEnable = 1 DriveControl0_ReverseDirection = 1 DriveControl0_ RunCommand = 1 To perform a Coast to Stop: DriveControl0_CoastStop = 1 To perform a Quick Stop: DriveControl0_QuickStop = 1 Acknowledge Fault: DriveControl0_FaultAcknowledge = 1 14 Controlling the Siemens Drive Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 72 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 15 Download Project to the Rockwell Controller Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 73 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 15 Download Project to the Rockwell Controller Click Communications. Click Who Active. Click Set Project Path. Click Download. Follow instructions before downloading. Click download. 15 Download Project to the Rockwell Controller Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 74 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Click Yes. 16 Create a Rockwell’s FactoryTalk View Application Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 75 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 16 Create a Rockwell’s FactoryTalk View Application Click New. Assign Application name. Select Language from the pulldown. Select Resolution from the pulldown. Click Create. 17 Establish Communications Between the Rockwell Controller and the Rockwell PanelView Plus Terminal Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 76 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 17 Establish Communications Between the Rockwell Controller and the Rockwell PanelView Plus Terminal Expand FactoryTalk Linx. Double click Communication Setup. FactoryTalk Linx Runtime Configuration Wizard: Select an operation about runtime configuration. Select create a new configuration. Click Finish. Click Add. Assign shortcut name. Press Enter. Select the appropriate controller. Click Apply. 17 Establish Communications Between the Rockwell Controller and the Rockwell PanelView Plus Terminal Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 77 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Click Yes. Click Copy from Design to Runtime. 17 Establish Communications Between the Rockwell Controller and the Rockwell PanelView Plus Terminal Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 78 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Click Yes. Click OK. 18 Import Siemens Global Objects Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 79 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 18 Import Siemens Global Objects Expand Graphics. Right click on Global Objects. Click Import and Export. Select Import graphic information into displays. Click Next. 18 Import Siemens Global Objects Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 80 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Select No. Click Next. Select Multiple displays batch import file. Click Next. 18 Import Siemens Global Objects Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 81 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Browse to the folder where the global object resides. Select BatchImport_Global_IO Monitor. Click Open. 18 Import Siemens Global Objects Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 82 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Click Finish. Exit Notepad. 18 Import Siemens Global Objects Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 83 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 19 Import Siemens Display Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 84 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 19 Import Siemens Display Expand Graphics. Right click on Displays. Click Import and Export. Select Import graphic information into displays. Click Next. 19 Import Siemens Display Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 85 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Select No. Click Next. Select Multiple displays batch import file. Click Next. 19 Import Siemens Display Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 86 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Browse to the folder where the display resides. Click Open. 19 Import Siemens Display Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 87 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Click Finish. Exit Notepad. 19 Import Siemens Display Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 88 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 20 Add GOTO Button to a Display Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 89 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 20 Add GOTO Button to a Display When the operator presses the Goto Display button at run time, the graphic display assigned to the button opens. Expand Graphics. Expand Global Objects. Double click IO Monitor. Right click on the motor icon. Click Copy. 20 Add GOTO Button to a Display Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1,10/2020 90 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Expand Graphics. Expand Displays. Select desired display. Right click on the display. Click Paste. Right click on the icon. Click Global Object Parameter Values. 20 Add GOTO Button to a Display Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 91 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Click Tag. 20 Add GOTO Button to a Display Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 92 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Select Refresh All Folders. Expand device shortcut. Expand Online. Select the appropriate controller tag. Click OK. Click OK. 20 Add GOTO Button to a Display Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 93 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d You have completed adding a GOTO button. 21 Alarms and Warnings Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 94 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 21 Alarms and Warnings Expand Alarms. Right click on Alarm Setup. Click Import and Export. Select Import alarm configuration into application. Click Next. 21 Alarms and Warnings Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 95 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Select No. Click Next. Click Browse. 21 Alarms and Warnings Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 96 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Browse to the appropriate folder. Select Alarm Setup. Click Open. 21 Alarms and Warnings Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 97 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Click Finish. Exit Notepad. 22 Edit Tags for Alarm Setup Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 98 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 22 Edit Tags for Alarm Setup Double click Alarm Setup Based on the controller tag name for the Add-On instruction, the triggers for the alarms may need to be Edited. Select the appropriate tag. Click Edit. Click Tag. 22 Edit Tags for Alarm Setup Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 99 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Select the appropriate tag. Click OK. Click OK. Repeat these steps for WarnCode. 23 Test Application Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 100 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 23 Test Application Click Application. Click Test Application. Click Motor. If DriveControl0_DriveEnable is energized from the external code, the Drive Enable Override button will be invisible. Click Manual. Enter Speed Setpoint (RPM). Click Start. 23 Test Application Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 101 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d The motor ramps to 250 RPM’s in the Forward direction based on the Acceleration rate. Click Forward. The motor ramps to -250 RPM’s in the Reverse direction based on the Deceleration rate. 23 Test Application Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 102 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Click Stop. The drive performs a Stop based on the Deceleration rate. Click Reverse. Click Start. The motor ramps to 250 RPM’s in the Forward direction based on the Acceleration rate. 23 Test Application Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 103 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Click Auto. The drive performs a Stop based on the Deceleration rate. Click Manual. Click Start. The motor ramps to 250 RPM’s in the Forward direction based on the Acceleration rate. 23 Test Application Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 104 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Click Close. The drive performs a Stop based on the Deceleration rate. The display closes and goes to the display where the motor is located. Click motor. Click Manual. Click Start. The motor ramps to 250 RPM’s in the Forward direction based on the Acceleration rate. 23 Test Application Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 105 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Remove the Ethernet cable from the PanelView Plus terminal. The drive performs a Stop based on the Deceleration rate. 23 Test Application Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 106 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Click Status. Status Word: Data from the drive to the PLC. Control Word: Data from the PLC to the drive. Click Faults. Click Acknowledge Faults to reset all active alarms. A warning is cleared when the drives Run Command is activated. If active, a Fault Code or Warning Code with appropriate description will be displayed. 23 Test Application Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 107 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 24 Transfer Utility Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 108 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 24 Transfer Utility Click Application. Click Create Runtime Application. Create Runtime Application: Save the file to the desired folder. Enter file name. Select type from the pulldown. Click Always Allow Conversion. Click Save. Click Tools. Click Transfer Utility. 24 Transfer Utility Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 109 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Click Download. Browse to select source file. Select destination storage from the pulldown. Select Run Application at Startup. Select Replace Communications and Delete Log files when application runs. Select the appropriate PanelView terminal. Click Download. Click OK. 24 Transfer Utility Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020110 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Click Exit. 25 Firmware Upgrade Wizard Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 111 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 25 Firmware Upgrade Wizard Click Tools. Click Firmware Upgrade Wizard. Select the type of firmware upgrade to perform: Click Upgrade firmware on terminal. Click Next. 25 Firmware Upgrade Wizard Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 112 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Click Yes. Select the type of connection to the terminal: Click Network connection. Click Next. 25 Firmware Upgrade Wizard Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 113 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Select the appropriate PanelView Plus terminal. Click Next. 25 Firmware Upgrade Wizard Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 114 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Firmware source folder: Leave as default. Upgrade firmware version: Select the appropriate version from the pulldown. Click Next. Select all the KEPServer drivers to be included in the firmware. Click Next. 25 Firmware Upgrade Wizard Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 115 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d Click Finish. 26 Appendix Integrating Siemens Drive into Rockwell Automations Studio 5000 Entry ID: 82843076, V2.0.1, 10/2020 116 © S ie m e n s A G 2 0 2 0 A ll ri g h ts r e s e rv e d 26 Appendix 26.1 Application Support Siemens AG Digital Industries Factory Automation Production Machines DI FA PMA APC Frauenauracher Str. 80 D-91056 Erlangen, Germany mailto: tech.team.motioncontrol@siemens.com 26.2 Links and Literature Table 26-1 No. Topic \1\ Siemens Industry Online Support https://support.industry.siemens.com \2\ Link to this entry page of this application example https://support.industry.siemens.com/cs/ww/en/109477746 \3\ Startdrive for commissioning G120 https://support.industry.siemens.com/cs/ww/en/view/109771710 \4\ Starter software for commissioning G120 https://support.industry.siemens.com/cs/ww/en/view/26233208 26.3 History Table 26-2 Version Date Modification V1.0 03/2020 First Version V2.0 09/2020 Second Version V2.0.1 10/2020 Manual optimized, no functional adaptions mailto:tech.team.motioncontrol@siemens.com https://support.industry.siemens.com/ https://support.industry.siemens.com/cs/ww/en/109477746 https://support.industry.siemens.com/cs/ww/en/view/109771710 https://support.industry.siemens.com/cs/ww/en/view/26233208 Integrating Siemens Drive into Rockwell Automations Studio 5000 using Free Telegram for Distributed Drives G110M and G120D Legal information 1 Overview 2 Telegram 3 Reference Scaling Parameters 4 Startdrive Configuration 5 Download to the drive 6 Motor Identification 7 Create New Project with Rockwell Software Studio 5000 8 Rockwell Automation EDS Wizard 9 Add a Siemens Drive to the Ethernet Network 10 Import Add-On Instruction 11 Configure IP Address for a Rockwell Controller 12 Configure RSLinx Communications for a Rockwell Controller 13 Insert a Rung for the Add-On Instruction 14 Controlling the Siemens Drive 15 Download Project to the Rockwell Controller 16 Create a Rockwell’s FactoryTalk View Application 17 Establish Communications Between the Rockwell Controller and the Rockwell PanelView Plus Terminal 18 Import Siemens Global Objects 19 Import Siemens Display 20 Add GOTO Button to a Display 21 Alarms and Warnings 22 Edit Tags for Alarm Setup 23 Test Application 24 Transfer Utility 25 Firmware Upgrade Wizard 26 Appendix 26.1 Application Support 26.2 Links and Literature 26.3 History
Compartilhar