Baixe o app para aproveitar ainda mais
Prévia do material em texto
LV product characteristics 2005 Circuit protection and control devices 0.5 to 6300 A cover.fm Page 1 Mercredi, 16. mars 2005 2:59 14 The Guiding System, the new way to create your electrical installations A comprehensive offer of products with consistent design The Guiding System is first and foremost a Merlin Gerin product offer covering all electrical distribution needs. However, what makes all the difference is that these products have been designed to operate together: mechanical and electrical compatibility, interoperability, modularity, communication. Thus the electrical installation is both optimised and more efficient: better continuity of supply, enhanced safety for people and equipment, guaranteed upgradeability, effective monitoring and control. Tools to simplify design and implementation With the Guiding System, you have a comprehensive range of tools - the Guiding Tools - that will help you increase your product knowledge and product utilisation. Of course this is in compliance with current standards and procedures. These tools include technical booklets and guides, design aid software, training courses, etc. and are regularly updated. For a genuine partnership with you Because each electrical installation is unique, there is no standard solution. With the Guiding System, the variety of combinations allows for genuine customisation solutions. You can create and implement electrical installations to meet your creative requirements and design knowledge. You and Merlin Gerin’s Guiding System form a genuine partnership. For more details on the Guiding System, consult www.merlin-gerin.com cover.fm Page 2 Mercredi, 16. mars 2005 2:59 14 1 0 A consistent design of offers from Medium Voltage to Ultra terminal All Merlin Gerin offers are designed according to electrical, mechanical and communication consistency rules. The products express this consistency by their overall design and shared ergonomics. Electrical consistency: Each product complies with or enhances system performance at co- ordination level: breaking capacity, Isc, temperature rise, etc. for more safety, continuity of supply (discrimination) or economic optimisation (cascading). The leading edge technologies employed in Merlin Gerin’s Guiding System ensure high performance levels in discrimination and cascading of protection devices, electrodynamic withstand of switches and current distributors, heat loss of devices, distribution blocks and enclosures. Likewise, inter-product ElectroMagnetic Compatibilty (EMC) is guaranteed.Discrimination guarantees co-ordination between the operating characteristics of serial-connected circuit-breakers. Should a fault occurs downstream, only the circuit-breaker placed immediately upstream from the fault will trip. Mechanical consistency: Each product adopts dimensional standards simplifying and optimising its use within the system. It shares the same accessories and auxiliaries and complies with global ergonomic choices (utilisation mode, operating mode, setting and configuration devices, tools, etc.) making its installation and operation within the system a simpler process. Prefabricated and tested solutions, upstream and downstream from the device complying with the IEC 60439-1 switchboard standard. Communication consistency: Each product complies with global choices in terms of communication protocols (Modbus, Ethernet, etc.) for simplified integration in the management, supervision and monitoring systems. Thanks to the use of standard Web technologies, you can offer your customers intelligent Merlin Gerin switchboards allowing easy access to information: follow-up of currents, voltages, powers, consumption history, etc. Guiding Tools for more efficient design and implementation of your installations. p01-04.fm Page 1 Lundi, 14. mars 2005 5:17 17 2 0 SM6 Medium voltage switchboard system from 1 to 36 kV Sepam Protection relays Masterpact Protection switchgear from 100 to 6300 A Trihal MV/LV dry cast resin transformer from 160 to 5000 kVA Evolis MV vacuum switchgear and components from 1 to 24 kV. The Technical guide These technical guides help you comply with installation standards and rules i.e.: The electrical installation guide, the protection guide, the switchboard implementation guide, the technical booklets and the co-ordination tables all form genuine reference tools for the design of high- performance electrical installations. For example, the LV protection co-ordination guide - discrimination and cascading - optimises choice of protection and connection devices while also increasing markedly continuity of supply in the installations. CAD software and tools The CAD software and tools enhance productivity and safety. They help you create your installations by simplifying product choice through easy browsing in the Guiding System offers. Last but not least, they optimise use of our products while also complying with standards and proper procedures. p01-04.fm Page 2 Lundi, 14. mars 2005 5:17 17 3 0 Compact Protection switchgear system from 100 to 630 A Multi 9 Modular protection switchgear system up to 125 A Prisma Plus Functional system for electrical distribution switchboards up to 3200 A Pragma Canalis Enclosures for distribution switchboards up to 160 A Prefabricated Busbar Trunking from 25 to 4000 A PowerLogic Power management Training Training allows you to acquire the Merlin Gerin expertise (installation design, work with power on, etc.) for increased efficiency and a guarantee of improved customer service. The training catalogue includes beginner’s courses in electrical distribution, knowledge of MV and LV switchgear, operation and maintenance of installations, design of LV installations to give but a few examples. p01-04.fm Page 3 Lundi, 14. mars 2005 5:17 17 4 p01-04.fm Page 4 Lundi, 14. mars 2005 5:17 17 5 Circuit protection and control devices Contents Multi 9 Multi 9 circuit breakers from 0.5 to 125 A 6 EasyPact EasyPact circuit breakers from 15 to 250 A 8 Compact NS Compact NS AC circuit breakers up to 630 A 10 Compact NS AC circuit breakers from 630 to 3200 A 12 Compact NS DC circuit breakers from 100 to 630 A 14 Masterpact NT and NW Masterpact NT06 to NT16 AC circuit breakers and switch-disconnectors from 630 to 1600 A 16 Masterpact NW08 to NW63 AC circuit breakers and switch-disconnectors from 800 to 6300 A 18 Masterpact NW10 to NW40 DC circuit breakers from 800 to 6300 A 20 Micrologic control units Overview of functions 22 Interpact INS Interpact INS40 to 160 switch-disconnectors 24 Interpact INS250-100 to 630 switch-disconnectors 28 Interpact INS630b to 2500 switch-disconnectors 32 Interpact INV Interpact INV100 to 630 switch-disconnectors 36 Interpact INV630b to 2500 switch-disconnectors 40 Fupact Fupact INFp32 to INFp800 switch-disconnector fuses 44 Fupact ISFT100 to ISFT630 fuse-switch disconnectors 48 Fupact ISFL160 to ISFL630 fuse-switch disconnectors 52 Vigirex Protection and monitoring relays 56 p05.fm Page 5 Lundi, 14. mars 2005 5:17 17 6 Multi 9 C60. DPN Vigi. C120. Multi 9 circuit breakers from 0.5 to 125 A NG125. 05 69 84 NR _2 1 PB 10 02 70 _1 6 05 67 38 R_ 29 05 69 08 NR -3 3 Multi 9 circuit breakers 6 to 1 to 4 to 6 to 6 to 32 A 40 A 40 A 45 A 40 A DPNa DPN N DPN N Vigi C60H RCBO C60a Number of poles 1 + N 1 + N 1 + N 1 + N 1 2- Electrical characteristics Rated current (A) In 30 °C 6-32 1-40 4-40 6-45 6-40 40 °C - - - - - Rated insulation voltage (V) Ui 300 300 300 440 500 Impulse withstand voltage (kV) Uimp4 4 4 4 6 Rated operational voltage (V) Ue AC 50/60 Hz 230 230 230 50-250 440 Fast closing b b b b b Disconnection with positive contact indication - b b - b AC breaking capacity (kA rms) - - - - - IEC 60947-2 (EN 60947-2) Icu 130 V - - - - 10 - 240 V - - - 10 5 10 400 V - - - - 3 5 415 V - - - - 3 5 440 V - - - - - 3 500 V - - - - - - Ics (% of Icu) - - - - 75 % IEC 60898 Icn 230/400 V 4.5 6 6 - 4.5 Ics 230/400 V 4.5 6 6 - 4.5 DC breaking capacity (kA) IEC 60947-2 (EN 60947-2) Icu 24/48 V - - - - - 60 V - 15 - - 10 (1P) 125 V - - - - 10 (2P) 125 V - - - - 20 (3P) 250 V - - - - 25 (4P) 500 V - - - - - Ics (% of Icu) 100 % 100 % - - 100 % Trip units (non adjustable) Curve type B (lm = 3.2 to 4.8 ln) b b b - b C (lm = 7 to 10 ln) b b b b b D (lm = 10 to 14 ln) - - - - - K (lm = 10 to 14 In) - - - - - Z (lm = 2.4 to 3.2) - - - - - MA (lm = 12 ln) - - - - - Personal protection Add-on rcd's (Vigi module) - - integrated integrated b 30-300 mA 10-100 mA Electrical auxiliaries Auxiliary and alarm switches (OF-SD) - b b - b Shunt trip (MX); undervoltage release (MN) - b b - b Installation Plug in base - - - - b Terminal shieds - - - - b Padlocking device - b b b b Rotary handle - - - - b Dimensions (mm) W 18 18 36 18 18/P H 81 81 81 111 81 D 70 70 70 73 73 p06-07.p65 14/03/2005, 17:066 7 Multi 9 1 to 4 to 6 to 6 to 0.5 to 63 A 0.5 to 32 to 50 to 63 to 10 to 125 A 10 to 80 A 4 to 40 A 40 A 45 A 40 A 25 A 40 A 63 A 125 A 80 A DPN N DPN N Vigi C60H RCBO C60a C60N C60H C60L C120N C120H NG125N NG125H NG125L NG125LMA 1 + N 1 + N 1 + N 1 2-3-4 1 2-3-4 1 2-3-4 1 2-3-4 1 2-3-4 1 2-3-4 1 2-3-4 1 2-3-4 1 2-3-4 1 2-3-4 1 2-3-4 - 2-3 1-40 4-40 6-45 6-40 63 63 - - - - - - - - - - - - - - - y 25 32-40 50-63 63-125 10-125 10-125 10-80 10-80 4-80 300 300 440 500 500 500 500 500 500 500 500 690 690 690 690 4 4 4 6 6 6 6 6 6 6 6 8 8 8 8 230 230 50-250 440 440 440 440 440 440 440 440 500 500 500 500 b b b b b b b b b b b b b b b b b - b b b b b b b b b b b b - - - - - - - - - - - - - - - - - - 10 - 20 - 30 - 50 - 50 - 50 - 20 - 30 - 50 - 70 - 100 - - - - 10 5 10 10 20 15 30 25 50 20 40 15 30 10 20 15 30 25 50 36 70 50 100 100 - - - 3 5 3 10 4 15 6 25 5 20 4 15 3 10 4.5 15 6 25 9 36 12.5 50 50 - - - 3 5 3 10 4 15 6 25 5 20 4 15 3 10 4.5 15 6 25 9 36 12.5 50 50 - - - - 3 - 6 - 10 - 20 - 15 - 10 - 6 - 10 - 20 - 30 - 40 40 - - - - - - - - - - - - - - - - - - - 6 8 6 10 6 12 12 - - - 75 % 75 % 50 % 50 % 50 % 50 % 75 % 50 % 75 % 75 % 75 % 75 % 6 6 - 4.5 6 10 - - - 10 15 - - - - 6 6 - 4.5 6 7.5 - - - 7.5 7.5 - - - - - - - - - - - - - 10 (1P) 15 (1P) - - - - 15 - - 10 (1P) 15 (1P) 20 (1P) 25 (1P) 25 (1P) 25 (1P) - - 25 (1P) 36 (1P) 50 (1P) - - - - 10 (2P) 20 (2P) 25 (2P) 30 (2P) 30 (2P) 30 (2P) 10 (1P) 15 (1P) 25 (1P) 36 (1P) 50 (1P) - - - - 20 (3P) 30 (3P) 40 (3P) 50 (3P) 50 (3P) 50 (3P) - - - - - - - - - 25 (4P) 40 (4P) 50 (4P) 60 (4P) 60 (4P) 60 (4P) 10 (2P) 15 (2P) 25 (2P) 36 (2P) 50 (2P) - - - - - - - - - - - - 25 (4P) 36 (4P) 50 (4P) - 100 % - - 100 % 100 % 100 % 100 % 100 % 100 % 100 % 100 % 100 % 100 % 100 % - b b - b b b b b b b b b - b - b b b b b b b b b b b b b b - - - - - b b b b b b b b - b - - - - - - - b b b - - - - - - - - - - - - b b b - - - - - - - - - - - - b y 40 A - - - - - b - integrated integrated b b b b b b b b b b 30-300 mA 10-100 mA b b - b b b b b b b b b b b b - b b b b b b b b b b - - - b b y 63 A - - - - b b b b b b b b b - - - b b b 18 36 18 18/P 27/P 27/P 81 81 111 81 81 103 70 70 73 73 73 81 p06-07.p65 14/03/2005, 17:067 8 EasyPact EasyPact circuit breakers from 15 to 250 A 0 D B1 06 89 1- 25 EZC100. EasyPact circuit breakers Number of poles Rated current (A) In at 40 °C Rated insulation voltage (V) Ui Rated impulse withstand voltage (kV) Uimp Rated operational voltage (V) Ue AC 50/60 Hz DC Electrical characteristics as per IEC 60947-2 and EN 60947-2 Ultimate breaking capacity (kA rms) Icu AC 50/60 Hz 110/130 V 220/230/240 V 380 V 400/415 V 440 V PB 10 12 10 a- 27 EZC250. 550 V DC 125 V (1P) 250 V (2P in series) Rated service breaking capacity Ics % Icu 110-400 V 415-550 V Suitability for isolation Utilisation category Pollution degree Endurance (C-O cycles) Mechanical Electrical In/415 V Electrical characteristics as per JIS C8370 Breaking capacity (kA) Icn AC 50/60 Hz 130 V 220 V 460 V Electrical characteristics as per NEMA-AB1 Breaking capacity (kA) HIC AC 50/60 Hz 240 V 277/480Y V Protection Overload protection Bimetal Instantaneous protection Magnetic Auxiliaries Indication contacts Auxiliary switch AX Alarm switch AL Combined AX + AL AXAL Voltage releases Shunt trip release SHT Undervoltage release UVR Installation Connection Crimp lugs/bars Accessories Box lugs for bare cables Rotary handles direct extended Terminal extensions Spreaders Phase barriers Terminal shields Padlocking system DIN rail plate Dimension and weight Dimensions (mm) W H D Weight (kg) (1) Only 3 poles. (2) 50 in 2 poles. p08-09.fm Page 8 Lundi, 14. mars 2005 5:20 17 9 EasyPact 0 EZC100B EZC100F EZC100N EZC100H EZC250F EZC250N EZC250H 3 3 1 3 1 2-3 3 3 2-3 15, 20, 25, 30, 40, 50, 60 15, 20, 25, 30, 40, 50, 60, 75, 80, 100 15, 20, 25, 30, 40, 50, 60, 75, 80, 100 15, 20, 25, 30, 40, 50, 60, 75, 80, 100 15, 20, 25, 30, 40, 50, 60, 75, 80, 100 15, 20, 25, 30, 40, 50, 60, 75, 80, 100 100, 125, 150, 160, 175, 200, 225, 250 100, 125, 150, 160, 175, 200, 225, 250 100, 125, 150, 160, 175, 200, 225, 250 690 690 690 690 690 690 690 690 690 6 6 6 6 6 6 6 6 6 550 - 550 250 550 250 550 250 550 250 550 250 550 250 550 250 550 250 10 25 25 25 50 100 25 50 85 10 25 18 25 25 100 (1) 25 50 85 7.5 10 2.5 18 5 30 18 25 36 7.5 10 2.5 15 5 30 18 25 36 5 7.5 - 10 - 20 15 20 25 2.5 5 - 5 - 10 5 8 10 - 5 5 5 - 5 5 10 - 10 10 5 5 20 20 30 30 - 25 % 50 % 50 % 50 % 50 % 50 % 50 % 50 % 50 % 25 % 50 % 50 % 50 % 50 % 25 % 50 % 50 % 50 % b b b b b b b b b A A A A A A A A A 3 3 3 3 3 3 3 3 3 8500 8500 8500 8500 8500 8500 10000 10000 10000 4000 4000 4000 4000 4000 4000 5000 5000 5000 10 25 15 25 30 100 30 50 85 10 25 - 25 - 100 30 50 85 5 7.5 - 10 - 25 15 25 35 - - 10 25 18 100 25 50 85 - - 10 10 18 18 (2) 15 18 25 (1) fixed fixed fixed fixed fixed fixed fixed fixed fixed fixed fixed fixed fixed fixed fixed fixed fixed fixed b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b - - - - - - b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b - - - 75 75 25 75 25 60 105 105 50 (2), 75 (1) 130 130 130 130 130 130 165 165 165 60 60 60 60 60 60 60 60 60 0.78 0.78 0.28 0.78 0.28 0.78 1.3 1.3 1.1 p08-09.fm Page 9 Lundi, 14. mars 2005 5:20 17 Compact NS 10 Compact NS AC circuit breakers up to 630 A Compact NS250H. Compact NS630N. PB 10 10 44 _4 2 (1) 2P in 3P case for type N only. (2) Specific trip units are available for operational voltages > 525 V. (3) NS100N et U u 500 V: Ics = 50 % Icu. (4) Operational voltage y 500 V. PB 10 10 50 _3 3 Compact circuit breakers NS125E Number of poles 3-4 Control manual toggle b direct or extended rotary handle - electric - Connections fixed front connection b rear connection b plug-in (on base) front connection - rear connection - withdrawable (on chassis) front connection - rear connection - Electrical characteristics as per IEC 60947-2 and EN 60947-2 Rated current (A) In 40 °C 125 65 °C - Rated insulation voltage (V) Ui 750 Rated impulse withstand voltage (kV) Uimp 8 Rated operational voltage (V) Ue AC 50/60 Hz 500DC - Type of circuit breaker E Ultimate breaking capacity (kA rms) lcu AC 220/240 V 25 50/60 Hz 380/415 V 16/10 440 V 10 500 V 6 525 V - 660/690 V - Service breaking capacity (kA rms) lcs % Icu 50 % Suitability for isolation b Utilisation category A Durability (C-O cycles) mechanical 10000 electrical 440 V In/2 6000 In 6000 Electrical characteristics as per NEMA AB1 (H.I.C.) E Breaking capacity (kA) 240 V 5 480 V 5 600 V - Electrical characteristics as per UL508 E Breaking capacity (kA) 240 V - 480 V - 600 V - Protection Trip units non interchangeable Overload protection long time Ir (In x …) 12.5… 125 (A) Short-circuit protection short time lsd (Ir x …) - instantaneous Ii (In x …) - Earth-fault protection lg (In x …) - Zone selective interlocking ZSI - Add-on earth-leakage protection add-on Vigi module b combination with Vigirex relay b Current measurements - Additional measurement, indication and control auxiliaries Indication contacts b MX shunt and MN undervoltage releases b Voltage-presence indicator - Current-transformer module and ammeter module - Insulation-monitoring module - Remote communication by bus Device-status indication - Device remote operation - Transmission of settings - Indication and identification of protection devices and alarms - Transmission of measured current values - Installation Accessories terminal extensions and spreaders b terminal shields and interphase barriers b escutcheons b Dimensions (mm) W x H x D fixed, front connections 2-3P / 4P 105 x 161 x 86 Weight (kg) fixed, front connections 3P / 4P 1.8 / 2.3 Source changeover system Manual, remote-operated and automatic source changeover systems - p10-13.p65 14/03/2005, 17:1410 11 Compact NS NS125E NS100 NS160 NS250 NS400 NS630 3-4 2 (1)-3-4 2 (1)-3-4 2 (1)-3-4 3-4 3-4 b b b b b b or extended rotary handle - b b b b b - b b b b b front connection b b b b b b rear connection b b b b b b front connection - b b b b b rear connection - b b b b b front connection - b b b b b rear connection - b b b b b 7-2 125 100 160 250 400 630 - 100 150 220 320 500 750 750 750 750 750 750 8 8 8 8 8 8 /60 Hz 500 690 690 690 690 690 - 500 500 500 500 500 E N SX H L N SX H L N SX H L N H L N H L 220/240 V 25 85 90 100 150 85 90 100 150 85 90 100 150 85 100 150 85 100 150 Hz 380/415 V 16/10 36 50 70 150 36 50 70 150 36 50 70 150 50 70 150 50 70 150 440 V 10 35 50 65 130 35 50 65 130 35 50 65 130 42 65 130 42 65 130 500 V 6 25 36 50 100 30 36 50 70 30 36 50 70 30 50 100 30 50 70 525 V - 22 35 35 100 22 35 35 50 22 35 35 50 22 35 100 22 35 50 660/690 V - 8 10 10 75 8 10 10 20 8 10 10 20 10 (2) 20 (2) 75 (2) 10 (2) 20 (2) 35 (2) 50 % 100 % (3) 100 % 100 % 100 % 100 % (4) b b b b b b A A A A A A 10000 50000 40000 20000 15000 15000 In/2 6000 50000 40000 20000 12000 8000 In 6000 30000 20000 10000 6000 4000 E N SX H L N SX H L N SX H L N H L N H L 5 85 90 100 200 85 90 100 200 85 90 100 200 85 100 200 85 100 200 5 35 50 65 130 35 50 65 130 35 50 65 130 42 65 130 42 65 130 - 8 20 35 50 20 20 35 50 20 20 35 50 20 35 50 20 35 50 E N SX H L N SX H L N SX H L N H L N H L - 85 85 85 - 85 85 85 - 85 85 85 - - - - - - - - 25 50 65 - 35 50 65 - 35 50 65 - - - - - - - - 10 10 10 - 10 10 10 - 18 18 18 - - - - - - - non interchangeable TM (thermal-magnetic) STR22 (electronic) STR23 (electronic) STR53 (electronic) …) 12.5… 125 (A) b b b b x …) - - b b b …) - b b b b x …) - - - - b - - - - b n Vigi module b b b b b nation with Vigirex relay b b b b b - - - - b b b b b b b - b b - b b - b b - b b b b - b b b b - - - - b - - - - b - - - - b nd spreaders b b b nterphase barriers b b b b b b ns 2-3P / 4P 105 x 161 x 86 105 x 161 x 86 / 140 x 161 x 86 140 x 255 x 110 / 185 x 255 x 110 ns 3P / 4P 1.8 / 2.3 2.0 to 2.2 / 2.6 to 2.8 6.2 to 8.1 - b b p10-13.p65 14/03/2005, 17:1411 Compact NS 12 E4 51 78 R _6 8 (1) 65 °C with vertical connections. See the temperature derating tables for other types of connections. (2) Ics: 100 % Icu for breaking capacity 440V/500V/660V Ics: 75 % Icu for breaking capacity 220V/380V. Compact NS1600H. Compact NS2000H. PB 10 12 06 _3 9 Compact circuit breakers NS630b NS80 Number of poles 3-4 Control manual toggle b direct or extended rotary handle b electric b Type of circuit breaker N H L Connections fixed front connection b b b rear connection b b b front connection with bare cables b b - withdrawable (on chassis) front connection b b b rear connection b b b Electrical characteristics as per IEC 60947-2 and EN 60947-2 Rated current (A) In 50 °C 630 800 65 °C (1) 630 800 Rated insulation voltage (V) Ui 750 Rated impulse withstand voltage (kV) Uimp 8 Rated operational voltage (V) Ue AC 50/60 Hz 690 DC 500 Type of circuit breaker N H L Ultimate breaking capacity (kA rms) lcu AC 220/240 V 50 70 150 50/60 Hz 380/415 V 50 70 150 440 V 50 65 130 500/525 V 40 50 100 660/690 V 30 42 25 DC 250 V - - - 500 V - - - Service breaking capacity (kA rms) lcs Value or % Icu manual operation 100 % 75 % 100 % electrical operation 75 % 50 % 100 % Short-time withstand current (kA rms) lcw 0.5 s 25 25 10 V AC 50/60 Hz 1 s 17 17 7 V AC 50/60 Hz 3 s - - - Integrated instantaneous protection kA peak ±10 % 55 Suitability for isolation b Utilisation category B B A Durability (C-O cycles) mechanical 10000 electrical 440 V In/2 6000 6000 4000 In 5000 5000 3000 690 V In/2 4000 4000 3000 In 2000 2000 2000 Pollution degree III Electrical characteristics as per Nema AB1 N H L Breaking capacity at 60 Hz (kA) 240 V 50 65 125 480 V 35 50 100 600 V 25 50 - Protection and measurements Interchangeable control units Micrologic 2.0 Overload protection long time Ir (In x …) b Short-circuit protection short time Isd (Ir x …) - instantaneous Ii (In x …) b Earth-fault protection lg (In x …) - Residual earth-leakage protection I∆∆∆∆∆n - Zone selective interlocking ZSI - Protection of the fourth pole b Current measurements - Remote communication by bus Device-status indication b Device remote operation b Transmission of settings - Indication and identification of protection devices and alarms - Transmission of measured current values - Additional indication and control auxiliaries Indication contacts b Voltage releases MX shunt release b MN undervoltage release b Installation Accessories terminal extensions and spreaders b terminal shields and interphase barriers b escutcheons b Dimensions fixed devices, front connections (mm) 3P 327 x 210 x 147 H x W x D 4P 327 x 280 x 147 Weight fixed devices, front connections (kg) 3P 14 4P 18 Source changeover system Manual, remote-operated and automatic source changeover systems b Compact NS AC circuit breakers from 630 to 3200 A p10-13.p65 14/03/2005, 17:1412 13 Compact NS NS630b NS800 NS1000 NS1250 NS1600 NS1600b NS2000 NS2500 NS3200 3-4 3-4 3-4 3-4 b b b b xtended rotary handle b b b - b b b - N H L N H N H N H ection b b b b b b b b b ection b b b b b b b - - ection with bare cables b b - b b - - - - ection b b b b b b b - - ection b b b b b b b - - 7-2 630 800 1000 1250 1600 1600 2000 2500 3200 630 800 1000 1250 1510 1550 1900 2500 2970 750 750 750 750 8 8 8 8 Hz 690 690 690 690 500 500 500 500 N H L N H N H N H 220/240 V 50 70 150 50 70 50 70 85 125 380/415 V 50 70 150 50 70 50 70 70 85 440 V 50 65 130 50 65 50 65 65 85 500/525 V 40 50 100 40 50 40 50 65 - 660/690 V 30 42 25 30 42 30 42 65 - 250 V - - - - - - - - - 500 V - - - - - - - - - % Icu manual operation 100 % 75 % 100 % 100 % 75 % 75 % 50 % 100 % (2) 75 % electrical operation 75 % 50 % 100 % 75 % 50 % 75 % 50 % 100 % (2) 75 % 25 25 10 25 25 25 25 - - 17 17 7 17 17 17 17 - - - - - - - - - 32 32 10 % 55 55 55 130 130 b b b b B B A B B B B B B10000 10000 10000 5000 In/2 6000 6000 4000 5000 5000 3000 In 5000 5000 3000 4000 2000 2000 In/2 4000 4000 3000 3000 2000 2000 In 2000 2000 2000 2000 1000 1000 III III III III N H L N H N H N H 240 V 50 65 125 50 65 50 65 85 125 480 V 35 50 100 35 50 35 50 65 85 600 V 25 50 - 25 50 25 50 50 - Micrologic 2.0 Micrologic 5.0 Micrologic 2.0 A Micrologic 5.0 A Micrologic 6.0 A Micrologic 7.0 A b b b b b b …) - b - b b b b b b b b b ) - - - - b - - - - - - b - - b b b b b b b b b b - - b b b b b b b b b b b b b b - - - - b b b b - - b b b b - - b b b b b b b b e b b spreaders b - rphase barriers b b b b 327 x 210 x 147 350 x 420 x 160 327 x 280 x 147 350 x 535 x 160 14 24 18 36 b - p10-13.p65 14/03/2005, 17:1513 14 Compact NS Compact NS DC circuit breakers from 100 to 630 A PB 10 10 47 a- 14 Compact circuit breakers Number of poles Electrical characteristics as per IEC 60947-1/ 60947-2 and EN 60947-1 / 60947-2 Rated current at 40 °C In (A) Rated insulation voltage Ui (V) Rated impulse withstand voltage Uimp (kV peak) Rated operational voltage Ue (V DC) Type of circuit breaker Ultimate breaking capacity (L/R = 5 ms and L/R = 15 ms) Icu (kA rms) V DC 48-125 V (1P) (1) 250 V (1P) (1) 500 V (2P) (1) 750 V (3P) (1) PB 10 10 48 a- 20 Service breaking capacity Ics % Icu Rated making capacity Icm % Icu Utilisation category Breaking time (ms) Suitability for isolation Pollution degree (as per IEC 60664-1) Protection against overcurrents (see "LV circuit breakers and switch-disconnectors direct current 16 to 4000 A" - ABTED205160EN) Trip units Built-in Interchangeable Protection Overloads Short-circuits Durability PB 10 10 55 a- 27 (O/F cycles) Mechanical Electrical 250 V In 250 V In/2 500 V In 500 V In/2 750 V In 750 V In/2 Indication and control auxiliaries Auxiliary contacts Voltage release MX shunt release MN undervoltage release Installation and connections Fixed Front connection PB 10 09 05 a -3 6 Rear connection Plug-in (base) Front connection Rear connection Withdrawable (chassis) Front connection Rear connection Dimensions and weight Dimensions H x W x D (mm) connected in series Fixed 1P 2P 3P 4P Weight (kg) connected in series Fixed 1P 2P 3P 4P (1) Number of poles taking part in current interruption. Example. The NS100N circuit breaker exists in the following versions: - 1 pole with an Icu of 50 kA, for systems y 250 V - 2 poles with an Icu of 85 kA, for systems y 500 V; 1 pole can be used in a 250 V system. p14-15.fm Page 14 Lundi, 14. mars 2005 5:22 17 15 Compact NS NS100 NS160 NS250 NS400 NS630 1 2 3-4 1 2 3-4 3-4 3-4 3-4 100 160 250 400 550 800 800 800 800 800 8 8 8 8 8 250 500 750 250 500 750 750 750 750 N H N H DC N H N H DC DC DC DC 50 85 85 100 100 50 85 85 100 100 100 100 100 50 85 85 100 100 50 85 85 100 100 100 100 100 - - 85 100 100 - - 85 100 100 100 100 100 - - - - 100 - - - - 100 100 100 100 100 % 100 % A < 10 ms b III b b b b - b b b b - - - - - - - - b - - - - b b b b b b b b b b b b b b - - - b b b b b b b b b b b b b 10000 5000 5000 1000 10000 2000 5000 1000 10000 2000 5000 1000 10000 2000 b b b b b - - - - b - - - - b b b b - - - - b - - - - b b b b - - - - b - - - - b b b b - - - - b - - - - b b b b 161 x 35 x 86 - - 161 x 35 x 86 - - - - 161 x 70 x 86 - - 161 x 70 x 86 - - - - 161 x 105 x 86 - - 161 x 105 x 86 255 x 140 x 110 - - 161 x 140 x 86 - - 161 x 140 x 86 225 x 185 x 110 0.7 - - 0.7 - - - - 1.2 - - 1.2 - - - - 1.6 to 1.9 - - 1.6 to 1.9 6.0 - - 2.1 to 2.3 - - 2.1 to 2.3 7.8 p14-15.fm Page 15 Lundi, 14. mars 2005 5:22 17 16 Masterpact NT and NW Masterpact NT06 to NT16 AC circuit breakers and switch-disconnectors from 630 to 1600 A 0 PB 10 07 67 a- 48 Common characteristics Number of poles 3-4 Rated insulation voltage (V) Ui 1000 Impulse withstand voltage (kV) Uimp 12 Rated operational voltage (V AC 50/60 Hz) Ue 690/1000 Suitability for isolation IEC 60947-2 Degree of pollution IEC 60664-1 3 Circuit-breaker characteristics as per IEC 60947-2 Rated current (A) In at 40 °C/50 °C (1) Rating of 4th pole (A) Sensor ratings (A) Type of circuit breaker Ultimate breaking capacity (kA rms) Icu 220/415 V V AC 50/60 Hz 440 V 525 V 690 V 1000 V Rated service breaking capacity (kA rms) Ics % Icu Utilisation category Rated short-time withstand current (kA rms) V AC 50/60 Hz Icw 0.5 s 1 s 3 s Integrated instantaneous protection (kA peak ±10 %) Rated making capacity (kA peak) Icm 220/415 V V AC 50/60 Hz 440 V 525 V 690 V 1000 V Break time (ms) between tripping order and arc extinction Closing time (ms) Circuit-breaker characteristics as per NEMA AB1 Breaking capacity (kA) V AC 50/60 Hz 240 V 480 V 600 V (1) 50 °C: rear vertical connected. Refer to temperature derating tables for other connection types. (2) See the current-limiting curves in the "additional characteristics" section. (3) SELLIM system. (4) Available for 480 V NEMA. (5) Suitable for motor control (direct-on-line starting). Switch-disconnector characteristics as per IEC 60947-3 and Annex A Type of switch-disconnector Rated making capacity (kA peak) Icm 220 V AC23A/AC3 category V AC 50/60 Hz 440 V 525/690 V 1000 V Rated short-time withstand current (kA rms) Icw 0.5 s AC23A/AC3 category V AC 50/60 Hz 1 s 3 s Ultimate breaking capacity Icu (kA rms) with an external protection relay Maximum time delay: 350 ms 690 V Mechanical and electrical durability as per IEC 60947-2/3 at In/Ie Service life Mechanical with maintenance C/O cycles x 1000 without maintenance Type of circuit breaker Rated current In (A) C/O cycles x 1000 Electrical without maintenance 440 V (4) IEC 60947-2 690 V 1000 V Type of circuit breaker or switch-disconnector Rated operationnal current Ie (A) AC23A C/O cycles x 1000 Electrical without maintenance 440 V (4) IEC 60947-3 690V Type of circuit breaker or switch-disconnector Rated operationnal current Ie (A) AC3 (5) Motor power 380/415 V (kW) 440 V (kW) C/O cycles x 1000 Electrical without maintenance 440 V (4) IEC 60947-3 Annex M/IEC 60947-4-1 690 V p16-19.fm Page 16 Lundi, 14. mars 2005 5:24 17 17 Masterpact NT and NW Sensor selection Sensor rating (A) 250 (1) 400 630 800 1000 1250 1600 Ir threshold setting(A) 100 to 250 160 to 400 250 to 630 320 to 800 400 to 1000 500 to 1250 640 to 1600 (1) For NT02 rating, please consult us. NT06 NT08 NT10 NT12 NT16 630 800 1000 1250 1600 630 800 1000 1250 1600 400 to 630 400 to 800 400 to 1000 630 to 1250 800 to 1600 H1 H2 L1 (2) H10 H1 H2 H10 42 50 150 - 42 50 - 42 50 130 - 42 50 - 42 42 100 - 42 42 - 42 42 25 - 42 42 - - - - 20 - - 20 100 % 100 % B B A B B B B 42 36 10 20 42 36 20 42 36 - 20 - 36 20 24 20 - - 24 20 - - 90 10 x In (3) - - 90 - 88 105 330 - 88 105 - 88 105 286 - 88 105 - 88 88 220 - 88 88 - 88 88 52 - 88 88 - - - - 42 - - 42 25 25 9 - 25 25 - < 50 < 50 42 50 150 - 42 50 - 42 50 100 - 42 50 - 42 42 25 - 42 42 - HA HA10 HA HA10 75 - 75 - 75 - 75 - 75 - 75 - - 42 - 42 36 20 36 20 36 20 36 20 20 20 20 20 36 36 25 12.5 H1 H2 L1 H10 H1 H2 L1 H10 H1 H2 L1 H10 H1 H2 H10 H10 H1 H2 630 800 1000 1250 1600 6 6 3 - 6 6 3 - 6 6 3 - 6 6 - - 6 6 3 3 2 - 3 3 2 - 3 3 2 - 3 3 - - 3 3 - - - 0.5 - - - 0.5 - - - 0.5 - - 0.5 0.5 - - H1/H2/HA 630 800 1000 1250 1600 6 6 6 6 6 3 3 3 3 3 H1/H2/HA 500 630 800 1000 1000 y 250 250 to 335 335 to 450 450 to 560 450 to 560 y 300 300 to 400 400 to 500 500 to 630 500 to 630 6 - p16-19.fm Page 17 Lundi, 14. mars 2005 5:24 17 18 Masterpact NT and NW Masterpact NW08 to NW63 AC circuitbreakers and switch-disconnectors from 800 to 6300 A PB 10 07 68 a- 38 Common characteristics Number of poles 3-4 Rated insulation voltage (V) Ui 1000/1250 Impulse withstand voltage (kV) Uimp 12 Rated operational voltage (V AC 50/60 Hz) Ue 690/1150 Suitability for isolation IEC 60947-2 Degree of pollution IEC 60664-1 4 (1000 V) / 3 (1250 V) Circuit-breaker characteristics as per IEC 60947-2 Rated current (A) at 40 °C / 50 °C (1) Rating of 4th pole (A) Sensor ratings (A) PB 10 07 69 a- 70 Type of circuit breaker Ultimate breaking capacity (kA rms) V AC 50/60 Hz Icu 220/415/440 V 525 V 690 V 1150 V Rated service breaking capacity (kA rms) Ics % Icu Utilisation category Rated short-time withstand current (kA rms) V AC 50/60 Hz Icw 1 s 3 s Integrated instantaneous protection (kA peak ±10 %) Rated making capacity (kA peak) V AC 50/60 Hz Icm 220/415/440 V 525 V 690 V 1150 V Break time (ms) between tripping order and arc extinction Closing time (ms) Circuit-breaker characteristics as per NEMA AB1 Breaking capacity (kA) V AC 50/60 Hz 240/480 V 600 V Unprotected circuit-breaker characteristics: tripping by shunt trip as per IEC 60947-2 Type of circuit breaker Ultimate breaking capacity (kA rms) V AC 50/60 Hz Icu 220...690 V Rated service breaking capacity (kA rms) Ics % Icu Rated short-time withstand current (kA rms) Icw 1 s 3 s Overload and short-circuit protection with external protection relay: short-circuit protection, maximum delay: 350 ms (4) Rated making capacity (kA peak) V AC 50/60 Hz Icm 220...690 V (1) 50 °C: rear vertical connected. Refer to temperature derating tables for other connection types. (2) See the current-limiting curves in the "additional characteristics" section. (3) Equipped with a trip unit with a making current of 90 kA peak. (4) External protection must comply with permissible thermal constraints of the circuit breaker (please consult us). No fault-trip indication by the SDE or the reset button. (5) Available for 480 V NEMA. (6) Suitable for motor control (direct-on-line starting). Switch-disconnector characteristics as per IEC 60947-3 and Annex A Type of switch-disconnector Rated making capacity (kA peak) AC23A/AC3 category V AC 50/60 Hz Icm 220...690 V 1150 V Rated short-time withstand current (kA rms) AC23A/AC3 category V AC 50/60 Hz Icw 0.5 s 1 s 3 s Mechanical and electrical durability as per IEC 60947-2/3 at In/Ie Service life Mechanical with maintenance C/O cycles x 1000 without maintenance Type of circuit breaker Rated current In (A) C/O cycles x 1000 Electrical without maintenance 440 V (5) IEC 60947-2 690 V 1150 V Type of circuit breaker or switch-disconnector Rated operational current Ie (A) AC23A C/O cycles x 1000 Electrical without maintenance 440 V (5) IEC 60947-3 690 V Type of circuit breaker or switch-disconnector Rated operational current Ie (A) AC3 (6) Motor power 380/415 V (kW) 440 V (5) (kW) 690 V (kW) C/O cycles x 1000 Electrical without maintenance 440/690 V (5) IEC 60947-3 Annex M/IEC 60947-4-1 p16-19.fm Page 18 Lundi, 14. mars 2005 5:24 17 19 Masterpact NT and NW Sensor selection Sensor rating (A) 250 (1) 400 630 800 1000 1250 1600 2000 2500 3200 4000 5000 6300 Ir threshold setting(A) 100 160 250 320 400 500 630 800 1000 1250 1600 2000 2500 to 250 to 400 to 630 to 800 to 1000 to 1250 to 1600 to 2000 to 2500 to 3200 to 4000 to 5000 to 6300 (1) For NW02 rating, please consult us. NW08 NW10 NW12 NW16 NW20 NW25 NW32 NW40 NW40b NW50 NW63 800 1000 1250 1600 2000 2500 3200 4000 4000 5000 6300 800 1000 1250 1600 2000 2500 3200 4000 4000 5000 6300 400 to 800 400 to 1000 630 to 1250 800 to 1600 1000 to 2000 1250 to 2500 1600 to 3200 2000 to 4000 2000 to 4000 2500 to 5000 3200 to 6300 N1 H1 H2 L1 (2) H10 H1 H2 H3 L1 (2) H10 H1 H2 H3 H10 H1 H2 42 65 100 150 - 65 100 150 150 - 65 100 150 - 100 150 42 65 85 130 - 65 85 130 130 - 65 85 130 - 100 130 42 65 85 100 - 65 85 100 100 - 65 85 100 - 100 100 - - - - 50 - - - - 50 - - - 50 - - 100 % 100 % 100 % 100 % B B B B 42 65 85 30 50 65 85 65 30 50 65 85 65 50 100 100 22 36 50 30 50 36 75 65 30 50 65 75 65 50 100 100 Without Without 190 80 Without Without 190 150 80 Without Without 190 150 Without Without 270 88 143 220 330 - 143 220 330 330 - 143 220 330 - 220 330 88 143 187 286 - 143 187 286 286 - 143 187 286 - 220 286 88 143 187 220 - 143 187 220 220 - 143 187 220 - 220 220 - - - - 105 - - - - 105 - - - 105 - - 25 25 25 10 25 25 25 25 10 25 25 25 25 25 25 25 < 70 < 70 < 70 < 80 42 65 100 150 - 65 100 150 150 - 65 100 150 - 100 150 42 65 85 100 - 65 85 100 100 - 65 85 100 - 100 100 HA HF (3) HA HF (3) HA HF (3) HA 50 85 50 85 55 85 85 100 % 100 % 100 % 100 % 50 85 50 85 55 85 85 36 50 36 75 55 75 85 Without Without Without Without Without Without Without 105 187 105 187 121 187 187 NW08 / NW10 / NW12 NW16 NW20 NW25 / NW32 / NW40 NW40b / NW50 / NW63 NA HA HF HA10 HA HF HA10 HA HF HA10 HA HF HA10 HA 88 105 187 - 105 187 - 105 187 - 121 187 - 187 - - - 105 - - 105 - - 105 - - 105 - - - - - - - - - - - - - - - 42 50 85 50 50 85 50 50 85 50 55 85 50 85 - 36 50 50 50 50 50 50 50 50 55 75 50 85 25 20 10 12.5 10 5 N1/H1/H2 L1 H10 H1/H2 L1 H10 H1/H2 H3 H10 H1 H2 800/1000/1250/1600 2000 2500/3200/4000 4000b/5000/6300 10 3 - 8 3 - 5 1.25 - 1.5 1.5 10 3 - 6 3 - 2.5 1.25 - 1.5 1.5 - - 0.5 - - 0.5 - - 0.5 - - H1/H2/NA/HA/HF H1/H2/H3/HA/HF H1/H2/HA 800/1000/1250/1600 2000 2500/3200/4000 4000b/5000/6300 10 8 5 1.5 10 6 2.5 1.5 H1/H2/HA/HF H1/H2/H3/HA/HF 800 1000 1250 1600 2000 335 to 450 450 to 560 560 to 670 670 to 900 900 to 1150 400 to 500 500 to 630 500 to 800 800 to 1000 1000 to 1300 y 800 800 to 1000 1000 to 1250 1250 to 1600 1600 to 2000 6 p16-19.fm Page 19 Lundi, 14. mars 2005 5:24 17 20 Masterpact NT and NW Masterpact NW10 to NW40 DC circuit breakers from 800 to 6300 A E8 81 93 a -3 1 Masterpact circuit breakers Number of poles Version C or D Version E Electrical characteristics as per IEC 60947-1/ 60947-2 and EN 60947-1 / 60947-2 Rated current at 40 °C / 50 °C (1) In (A) Rated insulation voltage Ui (V) Rated impulse withstand voltage Uimp (kV peak) Rated operational voltage Ue (V DC) Type of circuit breaker Ultimate breaking capacity L/R = 5 ms Icu (kA) V DC 500 750 PB 10 11 29 a- 34 900 L/R = 15 ms Icu 500 750 900 L/R = 30 ms Icu 500 750 900 Service breaking capacity Ics % Icu Rated making capacity Icm % Icu NW10DC 4P. Short-time withstand current Icw 1 s Utilisation category Breaking time (ms) Making time (ms) Suitability for isolation Pollution degree (as per IEC 60664-1) Protection against overcurrents (see "LV circuit breakers and switch-disconnectors direct current 16 to 4000 A" - ABTED205160EN) Trip units Built-in Protection Overloads Short-circuits Durability (O/F cycles) Mechanical With maintenance Without maintenance Electrical Without maintenance 500 V CC 900 V CC Indication and control auxiliaries Auxiliary contacts Voltage release MX shunt release MN undervoltage release Characteristics of switch-disconnectors as per IEC 60947-3 and EN 60947-3 Type of switch-disconnector Rated making capacity Icm % Icu Rated short-time withstand current Icw 1 s Installation and connections Connection Drawout 3P RC Horizontal 4P Vertical Fixed 3P RC Horizontal 4P Vertical Dimensions and weight Dimensions H x W x D (mm) connected in series Drawout 3P 4P Fixed 3P 4P Weight (kg) connected in series (approximate values) Drawout 3P 4P Fixed 3P 4P (1) 50 °C - see the derating table for the NW40. p20-21.fm Page 20 Lundi, 14. mars 2005 5:25 17 21 Masterpact NT and NW NW10 NW20 NW40 3 3 3 4 4 4 1000 2000 4000 1000 2000 4000 12 1212 500/900 500/900 500/900 N H N H N H 85 100 85 100 85 100 - 85 - 85 - 85 - 85 - 85 - 85 35 85 35 85 35 85 - 50 - 50 - 50 - 35 - 35 - 35 25 50 25 50 25 50 - 50 - 50 - 50 - 25 - 25 - 25 100 % 100 % 50 85 50 85 50 85 B 30 to 75 < 70 b b b b b b 4 b b b b b b - - - - - - b b b b b b 20000 10000 8500 5000 2000 - 2000 - 2000 - 1000 b b b b b b b b b b b b b b b b b b HA HA HA - 85 - 85 - 85 - 85 - 85 - 85 b b b b - - b b b b b b b b b b - - b b b b b b 439 x 441 x 494 439 x 441 x 594 439 x 556 x 494 439 x 556 x 594 352 x 422 x 427 352 x 422 x 527 352 x 537 x 427 352 x 537 x 527 90 to 116 125 to 146 60 to 86 85 to 106 p20-21.fm Page 21 Lundi, 14. mars 2005 5:25 17 22 Micrologic control units Overview of functions 0 All Masterpact and Compact NS630b up to 3200 A are equipped with a Micrologic control unit that can be changed on site. Control units are designed to protect Power circuits and loads. Alarms may be programmed for remote indications. Measurements of current, voltage, frequency, power and power quality optimise continuity of service and energy management. Dependability Integration of protection functions in an ASIC electronic component used in all Micrologic control units guarantees a high degree of reliability and immunity to conducted or radiated disturbances. On Micrologic A, P and H control units, advanced functions are managed by an independent microprocessor. Note: in the event of Masterpact circuit breaker DC, there is a version Micrologic 1.0 DC. For more information, consult the "LV circuit breakers and switch-disconnectors direct current 16 to 4000 A" catalogue - ABTED205160EN. Micrologic name codes Current protection X: type of protection b 2 for basic protection b 5 for selective protection b 6 for selective + earth-fault protection b 7 for selective + earth-leakage protection. Y: control-unit generation Identification of the control-unit generation. "0" signifies the first generation. Z: type of measurement b A for "ammeter" b P for "power meter" b H for "harmonic meter". Micrologic 2: basic protection D B1 01 11 6 Protection: long time + instantaneous Micrologic 5: basic protection D B1 01 11 7 Protection: long time + short time + instantaneous PB 10 07 72 a- 32 Micrologic 6: selective + earth-fault protection D B1 01 11 7 D B1 01 11 8 Protection: long time + short time + instantaneous + earth fault Micrologic 7: selective + earth-leakage protection D B1 01 11 7 D B1 01 11 9 Protection: long time + short time + instantaneous + earth leakage 2.0 A X Y Z p22-23.fm Page 22 Lundi, 14. mars 2005 5:26 17 23 Micrologic control units 0 Measurements and programmable protection A: ammeter b I1, I2, I3, IN, Iearth-fault, Iearth-leakage and maximeter for these measurements b fault indications b settings in amperes and in seconds. P: A + power meter + programmable protection b measurements of V, A, W, VAR, VA, Wh, VARh, VAh, Hz, Vpeak, Apeak, power factor and maximeters and minimeters b IDMTL long-time protection, minimum and maximum voltage and frequency, voltage and current imbalance, phase sequence, reverse power b load shedding and reconnection depending on power or current b measurements of interrupted currents, differentiated fault indications, maintenance indications, event histories and time-stamping, etc. H: P + harmonics b power quality: fundamentals, distortion, amplitude and phase of harmonics up to the 31st order b waveform capture after fault, alarm or on request b enhanced alarm programming: thresholds and actions. 2.0 A D B1 01 12 0 5.0 A D B1 01 12 1 5.0 P D B1 01 12 2 5.0 H D B1 01 12 2 6.0 A D B1 01 12 3 6.0 P D B1 01 12 4 6.0 H D B1 01 12 4 7.0 A D B1 01 12 3 7.0 P D B1 01 12 4 7.0 H D B1 01 12 4 p22-23.fm Page 23 Lundi, 14. mars 2005 5:26 17 24 Interpact INS Interpact INS40 to 160 switch-disconnectors 0 05 21 64 a -3 8 Interpact INS80 switch-disconnector. Interpact INS switch-disconnectors Number of poles Electrical characteristics as defined by IEC 60947-1 / 60947-3 and EN 60947-1 / 60947-3 Conventional thermal current (A) Ith at 60 °C Conventional thermal current in enclosure Ithe at 60 °C Rated insulation level (V) Ui AC 50/60 Hz Impulse-withstand voltage (kV) Uimp Rated operational voltage (V) Ue AC 50/60 Hz DC Rated operational voltage AC20 and DC20 (V) AC 50/60 Hz Rated operational current (A) Ie Electrical AC 50/60 Hz 220-240 V 05 21 68 a- 50 Interpact INS160 switch-disconnector. 380-415 V 440-480 V (1) 500 V 660-690 V Electrical DC 125 V (2P in series) 250 V (4P in series) Rated operational power AC23 (kW) Electrical AC 50/60 Hz 220-240 V 230 V (NEMA) 380-415 V 440 V 480 V (NEMA) 500-525 V 660-690 V 05 92 02 a- 50 Interpact INS160 emergency-off switch-disconnector. Rated duties Uninterrupted duty Intermittent duty Short-circuit making capacity (kA peak) Icm Min. (switch-disconnector alone) Max. (with upstream protection circuit breaker) Short-time withstand current (A rms) Icw 1 s 3 s 20 s 30 s Suitability for isolation Durability (category A) (O - C-O cycles) Mechanical Electrical AC 50/60 Hz 220-240 V 380-415 V 440 V 500 V 690 V Electrical DC 250 V Positive contact indication Visible break Emergency-off switch disconnector Degree of pollution Upstream protection See the “LV switch-disconnectors - Interpact INS/INV 40 to 2500 A" catalogue (1) Suitable for 480 V NEMA. p24-27.fm Page 24 Lundi, 14. mars 2005 5:26 17 25 Interpact INS 0 INS40 INS63 INS80 INS100 INS125 INS160 3-4 3-4 3-4 3-4 3-4 3-4 40 63 80 100 125 160 40 63 80 100 125 160 690 690 690 750 750 750 8 8 8 8 8 8 500 500 500 690 690 690 250 250 250 250 250 250 690 690 690 750 750 750 AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A 40 40 63 63 80 80 100 100 125 125 160 160 40 40 63 63 80 72 100 100 125 125 160 160 40 40 63 63 80 63 100 100 125 125 160 160 40 32 63 40 80 40 100 100 125 125 160 160 - - - - - - 100 63 125 80 160 100 DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A 40 40 63 63 80 80 100 100 125 125 160 160 40 40 63 63 80 80 100 100 125 125 160 160 11 15 22 22 37 45 7,5 15 15 22 37 45 20 30 37 45 55 75 22 30 37 55 55 90 22 30 30 55 75 90 18,5 22 22 55 75 110 - - - 55 75 90 b b b b b b class 120 - 60 % class 120 - 60 % class 120 - 60 % class 120 - 60 % class 120 - 60 % class 120 - 60 % 15 15 15 20 20 20 75 75 75 154 154 154 3000 3000 3000 5500 5500 5500 1730 1730 1730 3175 3175 3175 670 670 670 1230 1230 1230 550 550 550 1000 1000 1000 b b b b b b 20000 20000 20000 15000 15000 15000 AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 - - - - - - 1500 1500 1500 1500 1500 1500 DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 b b b b b b - - - - - - b b b b b b III III III III III III - - - - - - p24-27.fm Page 25 Lundi, 14. mars 2005 5:26 17 26 Interpact INS Interpact INS40 to 160 switch-disconnectors 0 Interpact INS switch-disconnectors Installation Fixed, front connection Fixed, rear connection On symmetrical rails On a backplate Connection By cables To bare cable connectors By cables with lugs Directly to terminalsTo spreaders To vertical-connection adapters via cable-lug adapters Flat-facing bars Directly to terminals To spreaders Edgewise bars To vertical-connection adapters Indication and measurement auxiliaries Auxiliary contacts Voltage-presence indicator Current-transformer module Ammeter module Control, locking and interlocking Control Direct front rotary handle Extended front rotary handle Direct lateral rotary handle Extended lateral rotary handle Locking By keylock By padlocks Interlocking By keylock Mechanical Complete source-changeover assembly Operating torque (Nm) (typical value for 3-4 poles with front handle) Installation and connection accessories Bare cable connectors Rear connectors Terminal extensions Spreaders One-piece spreader Terminal shrouds Terminal shields Interphase-barrier Front panel escutcheons Coupling accessories Tightening torque for electrical connections (Nm) Dimensions and weights Overall dimensions H x W x D (mm) 3 poles 4 poles Approximate weight (kg) 3 poles 4 poles Enclosure dimensions for Ithe D B1 05 41 3 H x W x D (mm) p24-27.fm Page 26 Lundi, 14. mars 2005 5:26 17 27 Interpact INS 0 INS40 INS63 INS80 INS100 INS125 INS160 b b b b b b - - - b b b b b b - - - b b b b b b b b b b b b - - - b b b - - - - - - - - - - - - - - - b b b - - - - - - - - - - - - b b b b b b - - - - - - - - - - - - - - - - - - b b b b b b b b b b b b b b b b b b b b b b b b - - - - - - b b b b b b - - - - - - b b b b b b - - - b b b 0.7 < Nm < 1.3 0.7 < Nm < 1.3 0.7 < Nm < 1.3 1.4 < Nm < 2 1.4 < Nm < 2 1.4 < Nm < 2 b b b b b b - - - - - - - - - - - - - - - - - - - - - - - - b b b b b b b b b b b b b b b b b b - - - - - - - - - - - - 8 8 8 8 8 8 85 x 90 x 62.5 85 x 90 x 62.5 85 x 90 x 62.5 100 x 135 x 62.5 100 x 135 x 62.5 100 x 135 x 62.5 85 x 90 x 62.5 85 x 90 x 62.5 85 x 90 x 62.5 100 x 135 x 62.5 100 x 135 x 62.5 100 x 135 x 62.5 0.5 0.5 0.5 0.8 0.8 0.8 0.6 0.6 0.6 0.9 0.9 0.9 190 x 115 x 55 190 x 115 x 55 190 x 115 x 55 260 x 160 x 55 260 x 160 x 55 260 x 160 x 55 p24-27.fm Page 27 Lundi, 14. mars 2005 5:26 17 28 Interpact INS Interpact INS250-100 to 630 switch-disconnectors 0 05 66 48 a -4 1 Interpact INS250 switch-disconnector. Interpact INS switch-disconnectors Number of poles Electrical characteristics as defined by IEC 60947-1 / 60947-3 and EN 60947-1 / 60947-3 Conventional thermal current (A) Ith at 60 °C Conventional thermal current in enclosure Ithe at 60 °C Rated insulation level (V) Ui AC 50/60 Hz Impulse-withstand voltage (kV) Uimp Rated operational voltage (V) Ue AC 50/60 Hz DC Rated operational voltage AC20 and DC20 (V) AC 50/60 Hz Rated operational current (A) Ie Electrical AC 50/60 Hz 220-240 V 380-415 V 440-480 V (1) 500-525 V 05 66 52 a- 41 Interpact INS250 emergency-off switch-disconnector. 660-690 V Electrical DC 125 V (2P in series) 250 V (4P in series) Rated operational power AC23 (kW) Electrical AC 50/60 Hz 220-240 V 230 V (NEMA) 380-415 V 440 V 480 V (NEMA) 500-525 V 660-690 V Rated duties Uninterrupted duty Intermittent duty 05 94 87 a -4 9 Interpact INS400 switch-disconnector. Short-circuit making capacity (kA peak) Icm Min. (switch-disconnector alone) Max. (with upstream protection circuit breaker) Short-time withstand current (A rms) Icw 1 s 3 s 20 s 30 s Suitability for isolation Durability (category A) (O - C-O cycles) Mechanical Electrical AC 50/60 Hz 440 V 500 V 690 V Electrical DC 250 V Positive contact indication Visible break Emergency-off switch disconnector Degree of pollution 05 94 88 a -4 9 Interpact INS400 emergency-off switch-disconnector. Upstream protection See the “LV switch-disconnectors - Interpact INS/INV 40 to 2500 A" catalogue (1) Suitable for 480 V NEMA. (2) 550 A (DC). p28-31.fm Page 28 Lundi, 14. mars 2005 5:26 17 29 Interpact INS 0 INS250-100 INS250-160 INS250-200 INS250 INS320 INS400 INS500 INS630 3-4 3-4 3-4 3-4 3-4 3-4 3-4 3-4 100 160 200 250 320 400 500 630 100 160 200 250 320 400 500 630 (2) 750 750 750 750 750 750 750 750 8 8 8 8 8 8 8 8 690 690 690 690 690 690 690 690 250 250 250 250 250 250 250 250 750 750 750 750 750 750 750 750 AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A 100 100 160 160 200 200 250 250 320 320 400 400 500 500 630 630 100 100 160 160 200 200 250 250 320 320 400 400 500 500 630 630 100 100 160 160 200 200 250 250 320 320 400 400 500 500 630 630 100 100 160 160 200 200 250 250 320 320 400 400 500 500 630 630 100 100 160 160 200 200 250 250 320 320 400 400 500 500 630 630 DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC23B 100 100 160 160 200 200 250 250 320 320 400 400 500 500 550 550 630 100 100 160 160 200 200 250 250 320 320 400 400 500 500 550 550 630 22 45 55 75 90 110 132 200 22 45 55 75 90 110 150 200 45 75 90 132 160 200 250 315 55 90 110 150 185 220 250 400 55 90 110 150 185 220 250 375 55 110 132 160 220 250 355 400 55 90 160 210 250 400 500 560 b b b b b b b b class 120 - 60 % class 120 - 60 % class 120 - 60 % class 120 - 60 % class 120 - 60 % class 120 - 60 % class 120 - 60 % class 120 - 60 % 30 30 30 30 50 50 50 50 330 330 330 330 330 330 330 330 8500 8500 8500 8500 20000 20000 20000 20000 4900 4900 4900 4900 11500 11500 11500 11500 2200 2200 2200 2200 4900 4900 4900 4900 1800 1800 1800 1800 4000 4000 4000 4000 b b b b b b b b 15000 15000 15000 15000 10000 10000 10000 10000 AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC23A DC23B DC23A DC23B DC23A DC23B DC23A DC23B 1500 1500 1500 1500 1500 1500 1500 1500 1000 - 1000 - 1000 - 1000 200 b b b b b b b b - - - - - - - - b b b b b b b b III III III III III III III III - - - - - - - - p28-31.fm Page 29 Lundi, 14. mars 2005 5:26 17 30 Interpact INS Interpact INS250-100 to 630 switch-disconnectors 0 Interpact INS switch-disconnectors Installation Fixed, front connection Fixed, rear connection On symmetrical rails On a backplate Connection By cables To bare cable connectors By cables with lugs Directly to terminals To spreaders To vertical-connection adapters via cable-lug adapters Flat-facing bars Directly to terminals To spreaders Edgewise bars To vertical-connection adapters Indication and measurement auxiliaries Auxiliary contacts Voltage-presence indicator Current-transformer module Ammeter module Control, locking and interlocking Control Direct front rotary handle Extended front rotary handle Direct lateral rotary handle Extended lateral rotary handle Locking By keylock By padlocks Interlocking By keylock Mechanical Complete source-changeover assembly Operating torque (Nm) (typical value for 3-4 poles with front handle) Installation and connection accessories Bare cable connectors Rear connectors Terminal extensions Spreaders One-piece spreader Terminal shrouds Terminal shields Interphase-barrier Front panel escutcheons Coupling accessories Tightening torque for electrical connections (Nm) Dimensions and weights Overall dimensions H x W x D (mm) 3 poles 4 poles Approximate weight (kg) 3 poles 4 poles Enclosure dimensions for Ithe D B1 05 41 3 H x W x D (mm) p28-31.fm Page 30 Lundi, 14. mars 2005 5:26 17 31 Interpact INS 0 INS250-100 INS250-160 INS250-200 INS250INS320 INS400 INS500 INS630 b b b b b b b b b b b b b b b b - - - - - - - - b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b - - - - - - - - b b b b b b b b b b b b b b b b - - - - b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b - - - - b b b b - - - - b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b 5 < Nm < 6.2 5 < Nm < 6.2 5 < Nm < 6.2 5 < Nm < 6.2 13.5 < Nm < 16.5 13.5 < Nm < 16.5 13.5 < Nm < 16.5 13.5 < Nm < 16.5 b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b - - - - - - - - - - - - b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b 15 15 15 15 50 50 50 50 136 x 140 x 96 136 x 140 x 96 136 x 140 x 96 136 x 140 x 96 205 x 185 x 130 205 x 185 x 130 205 x 185 x 130 205 x 185 x 130 136 x 140 x 96 136 x 140 x 96 136 x 140 x 96 136 x 140 x 96 205 x 185 x 130 205 x 185 x 130 205 x 185 x 130 205 x 185 x 130 2 2 2 2 4.6 4.6 4.6 4.6 2.2 2.2 2.2 2.2 4.9 4.9 4.9 4.9 400 x 300 x 200 400 x 300 x 200 400 x 300 x 200 400 x 300 x 200 600 x 400 x 200 600 x 400 x 200 600 x 400 x 200 600 x 400 x 200 p28-31.fm Page 31 Lundi, 14. mars 2005 5:26 17 32 Interpact INS Interpact INS630b to 2500 switch-disconnectors 0 PB 10 00 16 a- 55 Interpact INS1600 switch-disconnector. Interpact INS switch-disconnectors Number of poles Electrical characteristics as defined by IEC 60947-1 / 60947-3 and EN 60947-1 / 60947-3 Conventional thermal current (A) Ith at 60 °C Conventional thermal current in enclosure Ithe at 60 °C Rated insulation level (V) Ui AC 50/60 Hz Impulse-withstand voltage (kV) Uimp Rated operational voltage (V) Ue AC 50/60 Hz DC Rated operational voltage AC20 and DC20 (V) AC 50/60 Hz Rated operational current (A) Ie Electrical AC 50/60 Hz 220-240 V 380-415 V PB 10 00 18 a- 55 Interpact INS1600 emergency-off switch-disconnector. 440-480 V (1) 500-525 V 660-690 V Electrical DC 125 V (2P in series) 250 V (4P in series) Rated operational power AC23 (kW) Electrical AC 50/60 Hz 220-240 V 380-400 V 415 V 500-525 V 660-690 V Rated duties Uninterrupted duty Intermittent duty PB 10 00 20 a- 65 Interpact INS2500 switch-disconnector. Short-circuit making capacity (kA peak) Icm Min. (switch-disconnector alone) Max. (with upstream protection circuit breaker) Short-time withstand current (A rms) Icw 0.5 s 0.8 s 1 s 3 s 20 s 30 s Suitability for isolation Durability (category B) (O - C-O cycles) Mechanical Electrical AC 50/60 Hz 220-240 V 380-415 V 440-480 V (1) 500-525 V 660-690 V Electrical DC 125 V (2P) 250 V (4P) Positive contact indication Visible break Emergency-off switch disconnector Degree of pollution Upstream protection See the “LV switch-disconnectors - Interpact INS/INV 40 to 2500 A" catalogue (1) Suitable for 480 V NEMA. (2) For vertical connection busbars only. For horizontal connection busbars, see derating charts in the “LV switch-disconnectors - Interpact INS/INV 40 to 2500 A" catalogue. p32-35.fm Page 32 Lundi, 14. mars 2005 5:29 17 33 Interpact INS 0 INS630b INS800 INS1000 INS1250 INS1600 INS2000 INS2500 3-4 3-4 3-4 3-4 3-4 3-4 3-4 630 800 1000 1250 1600 (2) 2000 2500 630 800 1000 1250 1600 (2) 2000 2500 1000 1000 1000 1000 1000 1000 1000 12 12 12 12 12 12 12 690 690 690 690 690 690 690 750 750 750 750 750 750 750 800 800 800 800 800 800 800 AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21B AC21A AC22B AC22A AC23A AC21B AC22B AC23B AC21B AC22B AC23B 630 630 630 800 800 800 1000 1000 1000 1250 1250 1250 1600 1450 1600 1450 1250 2000 2000 - 2500 2500 - 630 630 630 800 800 800 1000 1000 1000 1250 1250 1250 1600 1450 1600 1450 1250 2000 2000 - 2500 2500 - 630 630 630 800 800 800 1000 1000 1000 1250 1250 1250 1600 1250 1600 1250 1250 2000 2000 - 2500 2500 - 630 630 630 800 800 800 1000 1000 1000 1250 1250 1250 1600 1250 1600 1250 1250 2000 2000 - 2500 2500 - 630 630 630 800 800 800 1000 1000 1000 1250 1250 1250 1600 1250 1600 1250 1250 2000 2000 - 2500 2500 - DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21B DC22B DC23B DC21B DC22B DC23B 630/2 630/2 630/2 800/2 800/2 800/2 1000/2 1000/2 1000/2 1250/2 1250/2 1250/2 1600/2 1600/2 1600/2 2000/2 2000/2 - 2500/2 2500/2 - 630/4 630/4 630/4 800/4 800/4 800/4 1000/4 1000/4 1000/4 1250/4 1250/4 1250/4 1600/4 1600/4 1600/4 2000/4 2000/4 - 2500/4 2500/4 - 250 250 315 400 400 - - 400 400 560 710 710 - - 500 500 630 800 800 - - 560 560 710 900 900 - - 710 710 900 - - - - b b b b b b b class 120 - 60 % class 120 - 60 % class 120 - 60 % class 120 - 60 % class 120 - 60 % class 120 - 60 % class 120 - 60 % 75 75 75 75 75 105 105 330 330 330 75 75 105 105 50 50 50 50 50 50 50 42 42 42 42 42 50 50 35 35 35 35 35 50 50 20 20 20 20 20 30 30 10 10 10 10 10 13 13 8 8 8 8 8 11 11 b b b b b b b 5000 3000 3000 3000 3000 500 500 AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21B AC21A AC22B AC22A AC23B AC21B AC22B AC23B AC21B AC22B AC23B 1000 1000 1000 500 500 500 500 500 500 500 500 500 100 500 100 500 500 100 100 - 100 100 - 1000 1000 1000 500 500 500 500 500 500 500 500 500 100 500 100 500 500 100 100 - 100 100 - 1000 1000 1000 500 500 500 500 500 500 500 500 500 100 500 100 500 500 100 100 - 100 100 - 1000 1000 1000 500 500 500 500 500 500 500 500 500 100 500 100 500 500 100 100 - 100 100 - 1000 1000 1000 500 500 500 500 500 500 500 500 500 100 500 100 500 500 100 100 - 100 100 - DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23B DC21B DC22B DC23B DC21B DC22B DC23B 1000 1000 1000 500 500 500 500 500 500 500 500 500 500 500 500 100 100 - 100 100 - 1000 1000 1000 500 500 500 500 500 500 500 500 500 500 500 500 100 100 - 100 100 - b b b b b b b - - - - - - - b b b b b - - III III III III III III III - - - - - - - p32-35.fm Page 33 Lundi, 14. mars 2005 5:29 17 34 Interpact INS Interpact INS630b to 2500 switch-disconnectors 0 Interpact INS switch-disconnectors Installation Fixed, front connection Fixed, rear connection On symmetrical rails On a backplate Connection By cables To bare cable connectors By cables with lugs Directly to terminals To spreaders To vertical-connection adapters via cable-lug adapters Flat-facing bars Directly to terminals To spreaders Edgewise bars To vertical-connection adapters Indication and measurement auxiliaries Auxiliary contacts Voltage-presence indicator Current-transformer module Ammeter module Control, locking and interlocking Control Direct front rotary handle Extended front rotary handle Direct lateral rotary handle Extended lateral rotary handle Locking By keylock By padlocks Interlocking By keylock Mechanical Complete source-changeover assembly Operating torque (Nm) (typical value for 3-4 poles with front handle) Installation and connection accessories Bare cable connectors Rear connectors Terminal extensions Spreaders One-piece spreader Terminal shrouds Terminal shields Interphase-barrier Front panel escutcheons Coupling accessories Tightening torque for electrical connections (Nm) Dimensions and weights Overall dimensions H x W x D (mm) 3 poles 4 poles Approximate weight (kg) 3 poles 4 poles Enclosure dimensions for Ithe D B1 05 41 3 H x W x D (mm) p32-35.fm Page 34 Lundi, 14. mars 2005 5:29 17 35 Interpact INS 0 INS630b INS800 INS1000 INS1250 INS1600 INS2000 INS2500 b b b b b b b b b b b b b b - - - - - - - b b b b b b b - - - - - - - - - - - - b b - - - - - - - b b b b b -- b b b b b b b b b b b b - - b b b b b - - b b b b b b b - - - - - - - - - - - - - - - - - - - - - b b b b b b b b b b b b b b - - - - - - - - - - - - - - b b b b b b b b b b b b b b b b b b b b b - - - - - - - - - - - - - - 30 30 30 30 30 60 60 - - - - - - - - - - - - - - b b b b b b b b b b b b b b - - - - - - - - - - - - - - b b b b b b b b b b b b b b b b b b b b b - - - - - - - 50 50 50 50 50 50 50 300 x 340 x 146.5 300 x 340 x 146.5 300 x 340 x 146.5 300 x 340 x 146.5 300 x 340 x 146.5 440 x 347.5 x 227.5 440 x 347.5 x 227.5 300 x 410 x 146.5 300 x 410 x 146.5 300 x 410 x 146.5 300 x 410 x 146.5 300 x 410 x 146.5 440 x 462.5 x 227.5 440 x 462.5 x 227.5 14 14 14 14 14 35 35 18 18 18 18 18 45 45 - - - - - - - p32-35.fm Page 35 Lundi, 14. mars 2005 5:29 17 36 Interpact INV Interpact INV100 to 630 switch-disconnectors 0 05 66 50 a -4 8 Interpact INV250 switch-disconnector. Interpact INV switch-disconnectors Number of poles Electrical characteristics as defined by IEC 60947-1 / 60947-3 and EN 60947-1 / 60947-3 Conventional thermal current (A) Ith at 60 °C Conventional thermal current in enclosure Ithe at 60 °C Rated insulation level (V) Ui AC 50/60 Hz Impulse-withstand voltage (kV) Uimp Rated operational voltage (V) Ue AC 50/60 Hz DC Rated operational voltage AC20 and DC20 (V) AC 50/60 Hz Rated operational current (A) Ie Electrical AC 50/60 Hz 220-240 V 380-415 V 440-480 V (1) 500-525 V 660-690 V Electrical DC 05 66 54 a -4 8 Interpact INV250 emergency-off switch-disconnector. 125 V (2P in series) 250 V (4P in series) Rated operational power AC23 (kW) Electrical AC 50/60 Hz 220-240 V 230 V (NEMA) 380-415 V 440 V 480 V (NEMA) 500-525 V 660-690 V Rated duties Uninterrupted duty Intermittent duty Short-circuit making capacity (kA peak) Icm Min. (switch-disconnector alone) Max. (with upstream protection circuit breaker) Short-time withstand current (A rms) Icw 1 s 3 s 20 s 30 s Suitability for isolation Durability (category A) (O - C-O cycles) Mechanical Electrical AC 50/60 Hz 440 V 500 V 690 V Electrical DC 250 V Positive contact indication Visible break Emergency-off switch disconnector Degree of pollution Upstream protection See the “LV switch-disconnectors - Interpact INS/INV 40 to 2500 A" catalogue (1) Suitable for 480 V NEMA. (2) 550 A (DC). p36-39.fm Page 36 Lundi, 14. mars 2005 5:29 17 37 Interpact INV 0 INV100 INV160 INV200 INV250 INV320 INV400 INV500 INV630 3-4 3-4 3-4 3-4 3-4 3-4 3-4 3-4 100 160 200 250 320 400 500 630 100 160 200 250 320 400 500 630 (2) 750 750 750 750 750 750 750 750 8 8 8 8 8 8 8 8 690 690 690 690 690 690 690 690 250 250 250 250 250 250 250 250 750 750 750 750 750 750 750 750 AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A/B 100 100 100 160 160 160 200 200 200 250 250 250 320 320 320 400 400 400 500 500 500 630 630 630/630 100 100 100 160 160 160 200 200 200 250 250 250 320 320 320 400 400 400 500 500 500 630 630 630/630 100 100 100 160 160 160 200 200 200 250 250 250 320 320 320 400 400 400 500 500 500 630 630 630/630 100 100 100 160 160 160 200 200 200 250 250 200 320 320 320 400 400 400 500 500 500 630 630 500/630 100 100 100 160 160 160 200 200 200 250 250 200 320 320 320 400 400 400 500 500 500 630 550 500/630 DC21A DC22A DC23B DC21A DC22A DC23B DC21A DC22A DC23B DC21A DC22A DC23B DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A/B 100 100 100 160 160 160 200 200 200 250 250 200 320 320 320 400 400 400 500 500 500 550 550 550/630 100 100 100 160 160 160 200 200 200 250 250 200 320 320 320 400 400 400 500 500 500 550 550 550/630 22 45 55 75 90 110 132 200 22 45 55 75 90 110 150 200 45 75 90 132 160 200 250 315 55 90 110 150 185 220 250 400 55 50 110 150 185 220 250 375 55 110 132 132 220 250 355 400 55 90 160 160 250 400 500 560 b b b b b b b b class 120 - 60 % class 120 - 60 % class 120 - 60 % class 120 - 60 % class 120 - 60 % class 120 - 60 % class 120 - 60 % class 120 - 60 % 30 30 30 30 50 50 50 50 330 330 330 330 330 330 330 330 8500 8500 8500 8500 20000 20000 20000 20000 4900 4900 4900 4900 11500 11500 11500 11500 2200 2200 2200 2200 4900 4900 4900 4900 1800 1800 1800 1800 4000 4000 4000 4000 b b b b b b b b 15000 15000 15000 15000 10000 10000 10000 10000 AC22A AC23A AC22A AC23A AC22A AC23A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A/B 1500 1500 1500 1500 1500 1500 1500 1500 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000/- 1500 1500 1500 1500 1500 1500 1500 1500 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000/- 1500 1500 1500 1500 1500 1500 1500 1500 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000/200 DC22A DC23A DC22A DC23A DC22A DC23A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A/B 1500 1500 1500 1500 1500 1500 1500 1500 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000/200 b b b b b b b b b b b b b b b b b b b b b b b b III III III III III III III III - - - - - - - - p36-39.fm Page 37 Lundi, 14. mars 2005 5:29 17 38 Interpact INV Interpact INV100 to 630 switch-disconnectors 0 Interpact INV switch-disconnectors Installation Fixed, front connection Fixed, rear connection On symmetrical rails On a backplate Connection By cables To bare cable connectors By cables with lugs Directly to terminals To spreaders To vertical-connection adapters via cable-lug adapters Flat-facing bars Directly to terminals To spreaders Edgewise bars To vertical-connection adapters Indication and measurement auxiliaries Auxiliary contacts Voltage-presence indicator Current-transformer module Ammeter module Control, locking and interlocking Control Direct front rotary handle Extended front rotary handle Direct lateral rotary handle Extended lateral rotary handle Locking By keylock By padlocks Interlocking By keylock Mechanical Complete source-changeover assembly Operating torque (Nm) (typical value for 3-4 poles with front handle) Installation and connection accessories Bare cable connectors Rear connectors Terminal extensions Spreaders One-piece spreader Terminal shrouds Terminal shields Interphase-barrier Front panel escutcheons Coupling accessories Tightening torque for electrical connections (Nm) Dimensions and weights Overall dimensions H x W x D (mm) 3 poles 4 poles Approximate weight (kg) 3 poles 4 poles Enclosure dimensions for Ithe D B1 05 41 3 H x W x D (mm) p36-39.fm Page 38 Lundi, 14. mars 2005 5:29 17 39 Interpact INV 0 INV100 INV160 INV200 INV250 INV320 INV400 INV500 INV630 b b b b b b b b b b b b b b b b - - - - - - - - b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b - - - - - - - - b b b b b b b b b b b b b b b b - - - - b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b - - - - b b b b - - - - b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b - - - - - - - - 5 < Nm < 6.2 5 < Nm < 6.2 5 < Nm < 6.2 5 < Nm < 6.2 13,5 < Nm < 16.5 13,5 < Nm < 16.5 13,5 < Nm < 16.5 13,5 < Nm < 16.5 b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b - - - - - - - - b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b b 15 15 15 15 50 50 50 50 136 x 140 x 96 136 x 140 x 96 136 x 140 x 96 136 x 140 x 96 205 x 185 x 130 205 x 185 x 130 205 x 185 x 130 205 x 185 x 130 136 x 140 x 96 136 x 140 x 96 136 x 140 x 96 136 x 140 x 96 205 x 185 x 130 205 x 185 x 130 205 x 185 x 130 205 x 185 x 130 2 2 2 2 4.6 4.6 4.6 4.6 2.2 2.2 2.2 2.2 4.9 4.9 4.94.9 400 x 300 x 200 400 x 300 x 200 400 x 300 x 200 400 x 300 x 200 600 x 400 x 200 600 x 400 x 200 600 x 400 x 200 600 x 400 x 200 p36-39.fm Page 39 Lundi, 14. mars 2005 5:29 17 40 Interpact INV Interpact INV630b to 2500 switch-disconnectors 0 PB 10 00 17 a- 55 Interpact INV1600 switch-disconnector. Interpact INV switch-disconnectors Number of poles Electrical characteristics as defined by IEC 60947-1 / 60947-3 and EN 60947-1 / 60947-3 Conventional thermal current (A) Ith at 60 °C Conventional thermal current in enclosure Ithe at 60 °C Rated insulation level (V) Ui AC 50/60 Hz Impulse-withstand voltage (kV) Uimp Rated operational voltage (V) Ue AC 50/60 Hz DC Rated operational voltage AC20 and DC20 (V) AC 50/60 Hz Rated operational current (A) Ie Electrical AC 50/60 Hz 220-240 V 380-415 V PB 10 00 19 a- 55 Interpact INV1600 emergency-off switch-disconnector. 440-480 V (1) 500-525 V 660-690 V Electrical DC 125 V (2P in series) 250 V (4P in series) Rated operational power AC23 (kW) Electrical AC 50/60 Hz 220-240 V 380-400 V 415 V 500-525 V 660-690 V Rated duties Uninterrupted duty Intermittent duty PB 10 00 21 a- 65 Interpact INV2500 switch-disconnector. Short-circuit making capacity (kA peak) Icm Min. (switch-disconnector alone) Max. (with upstream protection circuit breaker) Short-time withstand current (A rms) Icw 0.5 s 0.8 s 1 s 3 s 20 s 30 s Suitability for isolation Durability (category B) (O - C-O cycles) Mechanical Electrical AC 50/60 Hz 220-240 V 380-415 V 440-480 V (1) 500-525 V 660-690 V Electrical DC 125 V (2P) 250 V (4P) Positive contact indication Visible break Emergency-off switch disconnector Degree of pollution Upstream protection See the “LV switch-disconnectors - Interpact INS/INV 40 to 2500 A" catalogue (1) Suitable for 480 V NEMA. (2) For vertical connection busbars only. For horizontal connection busbars, see derating charts in the “LV switch-disconnectors - Interpact INS/INV 40 to 2500 A" catalogue. p40-43.fm Page 40 Lundi, 14. mars 2005 5:30 17 41 Interpact INV 0 INV630b INV800 INV1000 INV1250 INV1600 INV2000 INV2500 3-4 3-4 3-4 3-4 3-4 3-4 3-4 630 800 1000 1250 1600 (2) 2000 2500 630 800 1000 1250 1600 (2) 2000 2500 1000 1000 1000 1000 1000 1000 1000 12 12 12 12 12 12 12 690 690 690 690 690 690 690 750 750 750 750 750 750 750 800 800 800 800 800 800 800 AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21B AC21A AC22B AC22A AC23A AC21B AC22B AC23B AC21B AC22B AC23B 630 630 630 800 800 800 1000 1000 1000 1250 1250 1250 1600 1450 1600 1450 1250 2000 2000 - 2500 2500 - 630 630 630 800 800 800 1000 1000 1000 1250 1250 1250 1600 1450 1600 1450 1250 2000 2000 - 2500 2500 - 630 630 630 800 800 800 1000 1000 1000 1250 1250 1250 1600 1250 1600 1250 1250 2000 2000 - 2500 2500 - 630 630 630 800 800 800 1000 1000 1000 1250 1250 1250 1600 1250 1600 1250 1250 2000 2000 - 2500 2500 - 630 630 630 800 800 800 1000 1000 1000 1250 1250 1250 1600 1250 1600 1250 1250 2000 2000 - 2500 2500 - DC21A DC22A DC23A DC21A DC22A DC23B DC21A DC22A DC23B DC21A DC22A DC23B DC21A DC22A DC23A DC21B DC22B DC23B DC21B DC22B DC23B 630/2 630/2 630/2 800/2 800/2 800/2 1000/2 1000/2 1000/2 1250/2 1250/2 1250/2 1600/2 1600/2 1600/2 2000/2 2000/2 - 2500/2 2500/2 - 630/4 630/4 630/4 800/4 800/4 800/4 1000/4 1000/4 1000/4 1250/4 1250/4 1250/4 1600/4 1600/4 1600/4 2000/4 2000/4 - 2500/4 2500/4 - 250 250 315 400 400 - - 400 400 560 710 710 - - 500 500 630 800 800 - - 560 560 710 900 900 - - 710 710 900 - - - - b b b b b b b class 120 - 60 % class 120 - 60 % class 120 - 60 % class 120 - 60 % class 120 - 60 % class 120 - 60 % class 120 - 60 % 75 75 75 75 75 105 105 330 330 330 75 75 105 105 50 50 50 50 50 50 50 42 42 42 42 42 50 50 35 35 35 35 35 50 50 20 20 20 20 20 30 30 10 10 10 10 10 13 13 8 8 8 8 8 11 11 b b b b b b b 5000 3000 3000 3000 3000 500 500 AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21A AC22A AC23A AC21B AC21A AC22B AC22A AC23B AC21B AC22B AC23B AC21B AC22B AC23B 1000 1000 1000 500 500 500 500 500 500 500 500 500 100 500 100 500 500 100 100 - 100 100 - 1000 1000 1000 500 500 500 500 500 500 500 500 500 100 500 100 500 500 100 100 - 100 100 - 1000 1000 1000 500 500 500 500 500 500 500 500 500 100 500 100 500 500 100 100 - 100 100 - 1000 1000 1000 500 500 500 500 500 500 500 500 500 100 500 100 500 500 100 100 - 100 100 - 1000 1000 1000 500 500 500 500 500 500 500 500 500 100 500 100 500 500 100 100 - 100 100 - DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21A DC22A DC23A DC21B DC22B DC23B DC21B DC22B DC23B 1000 1000 1000 500 500 500 500 500 500 500 500 500 500 500 500 100 100 - 100 100 - 1000 1000 1000 500 500 500 500 500 500 500 500 500 500 500 500 100 100 - 100 100 - b b b b b b b - - - - - - - b b b b b - - III III III III III III III - - - - - - - p40-43.fm Page 41 Lundi, 14. mars 2005 5:30 17 42 Interpact INV Interpact INV630b to 2500 switch-disconnectors 0 Interpact INS switch-disconnectors Installation Fixed, front connection Fixed, rear connection On symmetrical rails On a backplate Connection By cables To bare cable connectors By cables with lugs Directly to terminals To spreaders To vertical-connection adapters via cable-lug adapters Flat-facing bars Directly to terminals To spreaders Edgewise bars To vertical-connection adapters Indication and measurement auxiliaries Auxiliary contacts Voltage-presence indicator Current-transformer module Ammeter module Control, locking and interlocking Control Direct front rotary handle Extended front rotary handle Direct lateral rotary handle Extended lateral rotary handle Locking By keylock By padlocks Interlocking By keylock Mechanical Complete source-changeover assembly Operating torque (Nm) (typical value for 3-4 poles with front handle) Installation and connection accessories Bare cable connectors Rear connectors Terminal extensions Spreaders One-piece spreader Terminal shrouds Terminal shields Interphase-barrier Front panel escutcheons Coupling accessories Tightening torque for electrical connections (Nm) Dimensions and weights Overall dimensions H x W x D (mm) 3 poles 4 poles Approximate weight (kg) 3 poles 4 poles Enclosure dimensions for Ithe D B1 05 41 3 H x W x D (mm) p40-43.fm Page 42 Lundi, 14. mars 2005 5:30 17 43 Interpact INV 0 INV630b INV800 INV1000 INV1250 INV1600 INV2000 INV2500 b b b b b b b b b b b b b b - - - - - - - b b b b b b b - - - - - - - - - - - - b b - - - - - - - b b b b b - - b b b b b b b b b b b b - - b b b b b - - b b b b b b b - - - - - - - - - - - - - - - - - - - - - b b b b b b b b b b b b b b - - - - - - - - - - - - - - b b b b b b b b b b b b b b b b b b b b b - - - - - - - - - - - - - - 30 30 30 30 30 60 60 - - - - - - - - - - - - - - b b b b b b b b b b b b b b - - - - - - - - - - - - - - b b b b b b b b b b b b b b b b b b b b b - - - - - - - 50 50 50 50 50 50 50 300 x 340 x 146.5 300 x 340 x 146.5 300 x 340 x 146.5 300 x 340 x 146.5 300 x 340 x 146.5 440 x 347.5 x 227.5 440 x 347.5 x 227.5 300 x 340 x 146.5 300 x 340 x 146.5 300 x 340 x 146.5 300 x 340 x 146.5 300 x 340 x 146.5 440 x 462.5 x 227.5 440 x 462.5 x 227.5 14 14 14 14 14 35 35 18 18 18 18 18 45 45 - - - - - - - p40-43.fm Page 43 Lundi, 14. mars 2005 5:30 17 44 Fupact Fupact INFp32 to INFp800 switch-disconnector fuses 05 90 00 a- 2, 4x 2, 12 Fupact INFp switch-disconnector fuses Number of poles / type of fuse-link 3 poles / 3 fuse-links 4 poles / switched neutral
Compartilhar