Buscar

Cálculo Elevador de Canecas

Prévia do material em texto

312BE01
	312BE01
									Actual Values:
	Power Required to Drive the Pulley:	P=	(Fp*v)/6120=	175.29	kW				Fresh Feed	Bucket Elevator Load (kW)
	Effective Tension of Elevator Belt:	Fp=	Q + S=	10395.3	kg
	Weight of carrying materials to be loaded at the maximum in buckets in the loading:	Q=		10000	kg
	Resistance received by bucket at the boot pulley:	S=	(2*Qt*D)/v	395.35	kg
	Carrying Quantity:	Qt=		255	tons/hr
	Boot Pulley Diameter:	D=		80	cm
	Belt Speed:	v=		103.2	meter/min
	Back Calculations:
	Power Required to Drive the Pulley:	P=			kW
	Carrying Quantity:	Qt=	(((6120)*(P)/v)-Q)*(v/(2*D))		tons/hr
								103.2
Sheet2
	ELEVADOR DE CANECAS
									Valores reais:
	Energia necessária para acionar o tambor superior:	P=	(Fp*v)/6120=	38.73	kW	51.93	CV		Fresh Feed	Bucket Elevator Load (kW)
	Tensão efetiva da correia do elevador:	Fp=	Q + S=	2060.9	kg
	Peso dos materiais de transporte a serem carregados no máximo em caçambas no carregamento:	Q=		1800	kg
	Resistência recebida pela caçamba na polia da bota:	S=	(2*Qt*D)/v	260.87	kg
	Quantidade de transporte:	Qt=		250	tons/hr
	Diâmetro do tambor inferior:	D=		60	cm
	Velocidade da correia:	v=		115	meter/min
	Cálculos anteriores:
	Energia necessária para acionar o tambor:	P=			kW
	Quantidade de transporte:	Qt=	(((6120)*(P)/v)-Q)*(v/(2*D))		tons/hr
								103.2
Sheet3

Outros materiais

Materiais relacionados

Perguntas relacionadas

Perguntas Recentes