Baixe o app para aproveitar ainda mais
Prévia do material em texto
312BE01 312BE01 Actual Values: Power Required to Drive the Pulley: P= (Fp*v)/6120= 175.29 kW Fresh Feed Bucket Elevator Load (kW) Effective Tension of Elevator Belt: Fp= Q + S= 10395.3 kg Weight of carrying materials to be loaded at the maximum in buckets in the loading: Q= 10000 kg Resistance received by bucket at the boot pulley: S= (2*Qt*D)/v 395.35 kg Carrying Quantity: Qt= 255 tons/hr Boot Pulley Diameter: D= 80 cm Belt Speed: v= 103.2 meter/min Back Calculations: Power Required to Drive the Pulley: P= kW Carrying Quantity: Qt= (((6120)*(P)/v)-Q)*(v/(2*D)) tons/hr 103.2 Sheet2 ELEVADOR DE CANECAS Valores reais: Energia necessária para acionar o tambor superior: P= (Fp*v)/6120= 38.73 kW 51.93 CV Fresh Feed Bucket Elevator Load (kW) Tensão efetiva da correia do elevador: Fp= Q + S= 2060.9 kg Peso dos materiais de transporte a serem carregados no máximo em caçambas no carregamento: Q= 1800 kg Resistência recebida pela caçamba na polia da bota: S= (2*Qt*D)/v 260.87 kg Quantidade de transporte: Qt= 250 tons/hr Diâmetro do tambor inferior: D= 60 cm Velocidade da correia: v= 115 meter/min Cálculos anteriores: Energia necessária para acionar o tambor: P= kW Quantidade de transporte: Qt= (((6120)*(P)/v)-Q)*(v/(2*D)) tons/hr 103.2 Sheet3