Logo Passei Direto

H19-102_V2 0 HCSA-Sales-Transmission Access V2 0 Dumps

Ferramentas de estudo

Solved questions

Material
Study with thousands of resources!

Solved questions

Text Material Preview

Download the latest H19-102_V2.0 exam dumps PDF for Preparation.
1 / 5
Exam : H19-102_V2.0
Title :
https://www.passcert.com/H19-102_V2.0-ENU.html
HCSA-Sales-Transmission
& Access V2.0
Download the latest H19-102_V2.0 exam dumps PDF for Preparation.
2 / 5
1.DC908 key feature: 620,000+ optical devices have been commercially used worldwide, covering
various industries such as ISP, finance, etc.
A. TRUE
B. FALSE
Answer: B
Explanation:
The Huawei OptiXtrans DC908 is a Data Center Interconnect (DCI) solution tailored for high-performance,
low-latency, and simplified deployment in data center scenarios. While Huawei’s optical solutions,
including the DC908, are widely deployed globally, the specific claim of "620,000+ optical devices
commercially used worldwide" is not explicitly documented as a key feature of the DC908 in official
HCSA-Sales-Transmission & Access materials. The DC908’s key features focus on aspects like high
capacity (e.g., 88T per fiber), low power consumption (35% lower than the industry average), rapid
commissioning (within 8 minutes), and cost-effective payback (within 1 year for self-built networks). The
figure of 620,000+ devices might pertain to Huawei’s broader optical portfolio, but it is not a verified key
feature specific to the DC908. Thus, the statement is FALSE in this context.
Reference: Huawei HCSA-Sales-Transmission & Access training materials, DC908 product datasheet.
2.Which of the following are pain points of financial customers?
A. Frequent stock transactions
B. Financial disaster recovery
C. Financial network attacks
D. Increased leased line prices
Answer: B, C, D
Explanation:
Financial customers, particularly in Data Center Interconnect (DCI) scenarios, face specific challenges
that Huawei’s solutions like the OptiXtrans DC908 address. According to HCSA-Sales-Transmission &
Access documentation, key pain points for financial customers include:
Financial disaster recovery (B): Financial institutions require robust disaster recovery mechanisms to
ensure data integrity and business continuity, a critical need in DCI scenarios.
Financial network attacks (C): Cybersecurity is a major concern due to the sensitive nature of financial
data, making network security a top priority.
Increased leased line prices (D): Rising costs of leased lines push financial customers toward
cost-effective self-built networks, a pain point Huawei addresses with solutions like DC908.
Frequent stock transactions (A): While important, this is a business requirement rather than a technical
pain point related to transmission or access infrastructure. It’s not listed as a primary concern in the
context of DCI or POL solutions for financial customers.
Thus, B, C, and D are the verified pain points.
Reference: HCSA-Sales-Transmission & Access training slides, "Financial Industry DCI Scenarios."
3.POL (OLT & ONU) can be sold independently in office scenario.
A. TRUE
B. FALSE
Answer: A
Explanation:
Download the latest H19-102_V2.0 exam dumps PDF for Preparation.
3 / 5
Passive Optical LAN (POL) is an all-optical enterprise networking solution comprising Optical Line
Terminals (OLT) and Optical Network Units (ONU). In office scenarios, Huawei’s Campus OptiX POL
solution allows flexibility in deployment. Official HCSA-Sales-Transmission & Access documents confirm
that OLTs and ONUs can be sold independently based on customer needs, such as upgrading existing
infrastructure or deploying specific components in a phased approach. For example, an office might
procure an OLT to centralize management while adding ONUs later to expand coverage. This modularity
supports tailored solutions, making the statement TRUE.
Reference: Huawei Campus OptiX POL Solution Overview, HCSA-Sales-Transmission & Access training
materials.
4.In DCI scenarios, high-level customers’ major pain points are high costs and difficult O&M.
A. TRUE
B. FALSE
Answer: A
Explanation:
In Data Center Interconnect (DCI) scenarios, high-level customers—such as large enterprises, ISPs, and
financial institutions—face significant challenges, as outlined in HCSA-Sales-Transmission & Access
documentation.
The two major pain points are:
High costs: DCI traffic grows rapidly (over 50% annually), and bandwidth costs often double every two
years, making cost management a critical issue.
Difficult O&M (Operations & Maintenance): Traditional DCI setups involve complex network planning and
maintenance, often requiring skilled engineers, which increases operational complexity.
Huawei’s OptiXtrans DC908 addresses these with lower per-bit costs (e.g., 88T/fiber capacity) and
simplified O&M (e.g., one-click deployment). The statement aligns with documented customer pain points,
making it TRUE.
Reference: HCSA-Sales-Transmission & Access, DCI Scenarios Pain Points section.
5.Customer pain point: High costs. DCI traffic grows over 50% annually, while bandwidth cost doubles
every two years.
A. TRUE
B. FALSE
Answer: A
Explanation:
This statement directly reflects a well-documented pain point in DCI scenarios as per
HCSA-Sales-Transmission & Access materials. The rapid growth of DCI traffic (over 50% annually) is
driven by increasing data demands from cloud services, video streaming, and enterprise applications.
Meanwhile, bandwidth costs doubling every two years exacerbate the financial burden on customers,
pushing them toward cost-efficient solutions like Huawei’s DC908, which offers a payback period within 1
year for self-built networks. The statement accurately captures this dynamic, making it TRUE.
Reference: Huawei HCSA-Sales-Transmission & Access, DCI Customer Pain Points and Solutions
datasheet.
6.Which of the following are highlights of Ultra broadband & High Integration?
Download the latest H19-102_V2.0 exam dumps PDF for Preparation.
4 / 5
A. Hardware redundancy
B. Hybrid photoelectric integration
C. 9.6T/2U
D. 100G~800Gbit@per X
Answer: B, C, D
Explanation:
The highlights of "Ultra broadband & High Integration" pertain to Huawei’s advanced transmission
solutions, such as the OptiXtrans DC908, designed for DCI scenarios. According to
HCSA-Sales-Transmission & Access materials:
Hybrid photoelectric integration (B): This feature integrates optical and electrical components, reducing
complexity and improving efficiency, a hallmark of Huawei’s high-integration designs.
9.6T/2U (C): The DC908 delivers an industry-leading capacity of 9.6 terabits per second in a compact
2U form factor, emphasizing ultra-broadband capability and space efficiency.
100G~800Gbit@per X (D): This refers to the flexible, scalable bandwidth per port (ranging from 100G to
800G), a key feature for ultra-broadband applications in DCI.
Hardware redundancy (A): While important for reliability, it is not specifically highlighted under "Ultra
broadband & High Integration" but rather under stability or resilience features.
Thus, B, C, and D are the verified highlights.
Reference: Huawei OptiXtrans DC908 Product Brochure, HCSA-Sales-Transmission & Access training
slides.
7.DC908 key feature: The cost of self-built networks can be recovered within 1 year. The higher the
bandwidth, the shorter the payback period.
A. TRUE
B. FALSE
Answer: A
Explanation:
The Huawei OptiXtrans DC908 is designed to offer a cost-effective DCI solution, and this statement is
a verified key feature in HCSA-Sales-Transmission & Access documentation. The DC908’s high capacity
(88T/fiber) and low per-bit cost enable customers to recover the investment in self-built networks within 1
year, compared to expensive leased lines. Additionally, the scalability (e.g., 100G to 800G per wavelength)
means that higher bandwidth usage accelerates the payback period, as operational savings increase with
scale. This economic advantage is a core selling point, making the statement TRUE.
Reference: HCSA-Sales-Transmission & Access, DC908 Key Features section.
8.What are the following advantages of Campus OptiX in the airport scenario?
A. Smart O&M
B. Ultimate Wi-Fi Experience
C. Up to 40km Coverage
Answer: A,C
Explanation:
Huawei’s Campus OptiX, based on POL technology, is tailored for various scenarios, including airports.
According to HCSA-Sales-Transmission & Access documents, the key advantages in the airport scenario
include:
Download the latest H19-102_V2.0 exam dumps PDF for Preparation.
5 / 5
Smart O&M (A): Campus OptiX leverages eSight NMS for intelligent operations and maintenance,
simplifying network management in large-scale environments like airports.
Up to 40km Coverage (C): POL’s passive optical architecture supports long-distance coverage (up to
40km), ideal for expansive airport campuses.
Ultimate Wi-Fi Experience (B): While Campus OptiX supports high-speed connectivity, this advantage
is more emphasized in scenarios like hotels or offices with Wi-Fi roaming features, not specifically
highlighted for airports.
Thus, A and C are the verified advantages.
Reference: Huawei Campus OptiX Solution for Airports, HCSA-Sales-Transmission & Access training
materials.
9.POL is an all-optical local area network (LAN) designed for enterprise networks. It can be widely used in
campus networks of education, healthcare, airport, electric power, and smart city scenarios.
A. TRUE
B. FALSE
Answer: A
Explanation:
Passive Optical LAN (POL) is Huawei’s all-optical solution for enterprise networks, replacing traditional
copper-based LANs with fiber optics. HCSA-Sales-Transmission & Access materials confirm that POL,
part of the Campus OptiX portfolio, is designed for enterprise environments and is widely applicable in
scenarios such as:
Education (e.g., universities),
Healthcare (e.g., hospitals),
Airports,
Electric power, and
Smart cities.
Its benefits include simplified architecture, high bandwidth, and long-distance coverage (up to 40km),
making the statement TRUE.
Reference: Huawei POL Solution Whitepaper, HCSA-Sales-Transmission & Access training materials.
10.PON is short for Passive Optical Network. It is a point-to-multipoint (P2MP) access mode.
A. TRUE
B. FALSE
Answer: A
Explanation:
PON, or Passive Optical Network, is a telecom technology that uses fiber optics and passive components
(e.g., splitters) to deliver broadband access. According to HCSA-Sales-Transmission & Access
documentation, PON operates in a point-to-multipoint (P2MP) topology, where a single Optical Line
Terminal (OLT) at the service provider’s end connects to multiple Optical Network Units (ONUs) or Optical
Network Terminals (ONTs) at customer premises via a shared optical distribution network (ODN). This
distinguishes it from point-to-point (P2P) systems, which dedicate a fiber per user. The statement
accurately describes PON’s definition and architecture, making it TRUE.
Reference: HCSA-Sales-Transmission & Access, PON Technology Overview section.