Logo Passei Direto
Material
Study with thousands of resources!

Text Material Preview

<p>H19-402_V1.0</p><p>Exam Name: HCSP-Presales-Data Center Network</p><p>Planning and Design V1.0</p><p>Full version: 540 Q&As</p><p>Full version of H19-402_V1.0 Dumps</p><p>Share some H19-402_V1.0 exam dumps</p><p>below.</p><p>1. The main circuit of PDU8000 precision power distribution cabinet supports voltage harmonic</p><p>and current harmonic monitoring.</p><p>1 / 18</p><p>https://www.certqueen.com/H19-402_V1.0.html</p><p>A. True</p><p>B. False</p><p>Answer: A</p><p>2. What optional functions are available in PDU8000? (Multiple choice)</p><p>A. Input switch remote trip function</p><p>B. Temperature Monitoring Features</p><p>C. Branch switch hot-swap function</p><p>D. Earthquake resistance of magnitude 9</p><p>Answer: ABCD</p><p>3. Which method does FusionModule800 air conditioning configuration support?</p><p>A. N/N+1</p><p>B. N+1</p><p>C. N</p><p>D. None</p><p>Answer: A</p><p>4. What measures should be taken when the operating temperature of UPS2000-A is too high?</p><p>A. Switch to bypass mode</p><p>B. Switch to battery mode</p><p>C. Stop output and cut off power to load</p><p>D. No action</p><p>Answer: A</p><p>5. Huawei modular equipment room supports cold channel and hot channel</p><p>A. True</p><p>B. False</p><p>Answer: A</p><p>6. The two major parameters to consider when selecting a water pump are water volume and</p><p>head.</p><p>A. True</p><p>B. False</p><p>Answer: A</p><p>2 / 18</p><p>7. NetCol air conditioner 35kW/46kW supports linkage control of indoor and outdoor units.</p><p>A. True</p><p>B. False</p><p>Answer: A</p><p>8. The UPS5000-A parallel signal line does not use a ring connection, resulting in a single point</p><p>of failure, which reduces system reliability.</p><p>A. True</p><p>B. False</p><p>Answer: B</p><p>9. Which of the following is the type of UPS5000-E?</p><p>A. Industrial frequency machine</p><p>B. High frequency modularization</p><p>C. High frequency tower</p><p>Answer: B</p><p>10. What are the following models/capacities of Huawei's power module FusionPower6000?</p><p>(Multiple choice)</p><p>A. 2.4MW</p><p>B. 1.2MW</p><p>C. 2.0MW</p><p>D. 1.6MW</p><p>Answer: ABD</p><p>11. How many battery packs supported by a single UPS5000? (Multiple choice)</p><p>A. 4 groups</p><p>B. 1 group</p><p>C. 3 groups</p><p>D. Group 2</p><p>Answer: ABCD</p><p>12. NetCol5000-A042H full-cabinet row-level variable frequency air-cooled precision air</p><p>conditioner has load-clearing dehumidification function, which can meet the reliable</p><p>dehumidification under the minimum load of 10%, avoiding the hidden danger of condensation</p><p>in low-load and high-humidity environment</p><p>3 / 18</p><p>A. True</p><p>B. False</p><p>Answer: A</p><p>13. What kind of inlet and outlet wiring methods can be realized by FusionModule2000 precision</p><p>power distribution cabinet? (Multiple choice)</p><p>A. Inlet and outlet</p><p>B. Up-line in and down-line out</p><p>C. Lower inlet and upper outlet</p><p>D. Inlet and outlet</p><p>Answer: ABCD</p><p>14. Which of the following statements about surveillance cameras is incorrect?</p><p>A. Less than 4 cameras can be connected to the ETH socket</p><p>B. The camera is powered by PoE</p><p>C. The camera can be directly connected to a PoE powered switch</p><p>D. Camera data can be stored via TF card or VCN500</p><p>The number of E cameras is the same as the number of controlled sunroofs</p><p>Answer: E</p><p>15. For cabinets (racks) arranged in rows, when their length exceeds (), additional channels</p><p>should be added between two channels, and channels should be set up at both ends: when the</p><p>distance between two channels exceeds (), channels should be added directly between the two</p><p>channels.</p><p>A. 6m, 15m</p><p>B. 6m, 20m</p><p>C. 8m, 15m</p><p>D. 8m, 20m</p><p>Answer: A</p><p>16. FusionModule8003.0 version supports face recognition function.</p><p>A. True</p><p>B. False</p><p>Answer: A</p><p>17. Huawei FusionPower6000 is used with which of the following UPS products?</p><p>4 / 18</p><p>A. UPS5000-E</p><p>B. UPS5000-S</p><p>C. UPS5000-A</p><p>D. UPS5000-H</p><p>Answer: D</p><p>18. What are the following tasks in data center operation and maintenance? (Multiple choice)</p><p>A. Real-time monitoring</p><p>B. Routine Maintenance</p><p>C. Major overhaul</p><p>D. Emergency drills</p><p>Answer: ABCD</p><p>19. Which of the following communication functions does UPS5000-E include? (Multiple choice)</p><p>A. Dry contact card</p><p>B. RS485</p><p>C. SNMP</p><p>D. RS232</p><p>Answer: ABC</p><p>20. Which of the following is Fusionmodule2000 integrated UPS lightning protection level?</p><p>A. Class A lightning protection</p><p>B. Class B lightning protection</p><p>C. C-level lightning protection</p><p>Answer: C</p><p>21. NetCol8000-C room-level chilled water intelligent temperature control product has</p><p>components that can be maintained online, which can greatly reduce the time for component</p><p>replacement? (Multiple choice)</p><p>A. Main control module</p><p>B. Auxiliary source module</p><p>C. Electric heating</p><p>D. Fan</p><p>Answer: AB</p><p>22. Which of the following are FusionModule1000AV2R3 version 20-foot CT scene air</p><p>5 / 18</p><p>conditioning features? (Multiple choice)</p><p>A. Air cooling</p><p>B. Direct Expansion Refrigeration</p><p>C. Water cooling</p><p>D. Inverter compressor</p><p>E. Natural cooling technology</p><p>Answer: ABD</p><p>23. UPS5000 -E (25-125kVA) does not support iBattery function.</p><p>A. True</p><p>B. False</p><p>Answer: B</p><p>24. FusionModule2000 integrated UPS has two configurations: single MCCB and dual ATS.</p><p>A. True</p><p>B. False</p><p>Answer: A</p><p>25. The NetEco management system and the ECC800 collector use Huawei's private protocol</p><p>BIN protocol for communication.</p><p>A. True</p><p>B. False</p><p>Answer: A</p><p>26. 80k , an 80kVA UPS system can meet basic requirements.</p><p>A. True</p><p>B. False</p><p>Answer: B</p><p>27. How many poles of circuit breaker are generally used for the external maintenance bypass</p><p>of UPS system?</p><p>A. 3</p><p>B. 1</p><p>C. 4</p><p>D. 2</p><p>Answer: A</p><p>6 / 18</p><p>28. The power supply types of FusionModule800 and FusionModule500 are</p><p>380/400/415/3Ph/50Hz and 220/230/240/1Ph/50HZ respectively.</p><p>A. True</p><p>B. False</p><p>Answer: A</p><p>29. Which of the following are the advantages of Fusionmodule2000? (Multiple choice)</p><p>A. Rapid deployment</p><p>B. Flexible expansion</p><p>C. High reliability</p><p>Answer: ABC</p><p>30. What is the straight pipe distance of the NETCOL5000-C pipeline fixed title?</p><p>A. 3200MM</p><p>B. 3000MM</p><p>C. 2600MM</p><p>D. 2500MM</p><p>Answer: D</p><p>31. The minimum height of the equipment room required for FusionModule2000 is 2.6 meters.</p><p>A. True</p><p>B. False</p><p>Answer: A</p><p>32. When the voltage of a single cell in a battery pack reaches (), it means that the battery pack</p><p>is in a risky state.</p><p>A. 2.42V</p><p>B. 2.25V</p><p>C. 2.35V</p><p>D. 1.67V</p><p>Answer: D</p><p>33. Huawei Neteco network management supports mobile APP management</p><p>A. True</p><p>B. False</p><p>7 / 18</p><p>Answer: A</p><p>34. Which of the following models has the widest input voltage range and is more adaptable to</p><p>harsh power grids?</p><p>A. APC Galaxy7000</p><p>B. UPS5000-A</p><p>C. Emerson NXF</p><p>D. Eaton 9395</p><p>Answer: B</p><p>35. Which circuit breaker is used in the main circuit of PDU8000 precision power distribution</p><p>cabinet?</p><p>A. Molded case circuit breaker</p><p>B. Miniature circuit breaker</p><p>C. Frame Breaker</p><p>D. Isolating switch</p><p>Answer: A</p><p>36. FusionModule supports access card swiping but does not support two-way card swiping.</p><p>A. True</p><p>B. False</p><p>Answer: B</p><p>37. Huawei NMW intelligent bus supports () single/three-phase output channels.</p><p>A. 3/6</p><p>B. 6/6</p><p>C. 3/3</p><p>D. 6/3</p><p>Answer: D</p><p>38. The asset management in NetEco management system can manage the asset information</p><p>of which of the following devices to achieve asset life cycle management? (Multiple choice)</p><p>A. UPS</p><p>B. Air conditioning</p><p>C. Power distribution cabinet</p><p>D. Server</p><p>8 / 18</p><p>Answer: ABCD</p><p>39. The smoke sensors used in the NetEco6000 management system cannot replace the</p><p>smoke sensors in the fire protection system.</p><p>A. True</p><p>B. False</p><p>Answer: A</p><p>40. In Huawei FM2000, intelligent rPDU only supports C19 and C13 specifications.</p><p>A. True</p><p>B. False</p><p>Answer: A</p><p>41. Intelligent bus duct can replace precision configuration cabinets to increase the number of</p><p>IT cabinets.</p><p>A. True</p><p>B. False</p><p>Answer: A</p><p>42. PDU8000 precision power distribution cabinet supports main circuit phase current, active</p><p>power, electric energy and branch switch status monitoring</p><p>A. True</p><p>B. False</p><p>Answer: A</p><p>43. What is the rated voltage of the single cell (CELL) in the VRLA battery?</p><p>A. 12V</p><p>B. 6V</p><p>C. 2V</p><p>D. 1V</p><p>Answer: C</p><p>44. Compared with</p><p>high frequency machines, industrial frequency machines may bring more</p><p>additional investment, including? (Multiple choice)</p><p>A. Refrigeration electricity cost</p><p>B. Operating electricity costs</p><p>9 / 18</p><p>C. Computer room area</p><p>D. Oil engine</p><p>E. Load bearing (installation and construction)</p><p>Answer: ABCDE</p><p>45. NetEco6000 management system can provide which of the following access control card</p><p>readers? (Multiple choice)</p><p>A. IC card reader</p><p>B. Card reader with swipe and PIN</p><p>C. Swipe card fingerprint reader</p><p>Answer: ABC</p><p>46. What is the earthquake resistance level of Huawei Fusionmodule2000 IT cabinet?</p><p>A. 7</p><p>B. 8</p><p>C. 9</p><p>Answer: C</p><p>47. What is the UPS2000-G 6-20k host operation interface? which can display the system</p><p>status in real time.</p><p>A. LED</p><p>B. LCD</p><p>C. Touch screen</p><p>D. Remote network management</p><p>Answer: B</p><p>48. Data center management system NetEcoV6R8 version can support up to 100,000 test</p><p>points on a single server</p><p>A. True</p><p>B. False</p><p>Answer: A</p><p>49. When the power density of a single cabinet is greater than 10kl/R, which type of</p><p>refrigeration is recommended?</p><p>A. Room-level air conditioning upward air supply</p><p>B. Row-level air conditioning horizontal air supply closed channel</p><p>10 / 18</p><p>C. Unsealed horizontal air supply channel for row-level air conditioning</p><p>D. Room-level air conditioning</p><p>Answer: B</p><p>50. The control sunroof of Fusionmodule2000 cannot be flipped open.</p><p>A. True</p><p>B. False</p><p>Answer: A</p><p>51. What sensor does FusionModule2000 use to detect whether the air conditioner is leaking?</p><p>A. Multifunctional sensor</p><p>B. Infrared sensor</p><p>C. Temperature sensor</p><p>D. Water sensor</p><p>Answer: D</p><p>52. UPS5000-E comes standard with an LCD display screen that supports multiple languages</p><p>and can display the system operating status in real time. It can store up to () alarm records.</p><p>A. 2000</p><p>B. 2500</p><p>C. 3000</p><p>Answer: B</p><p>53. Huawei precision air conditioner NetCol500O-C030 fan cannot be maintained online.</p><p>A. True</p><p>B. False</p><p>Answer: B</p><p>54. UPS5000-S-400K uses () KVA power module</p><p>A. 25</p><p>B. 30</p><p>C. 40</p><p>D. 50</p><p>Answer: D</p><p>55. When competing with competitors, which of the following is correct? (Multiple choice)</p><p>11 / 18</p><p>A. Schneider can implement CPU-level energy consumption monitoring, but CPU energy</p><p>consumption does not represent the energy consumption of the entire device, so monitoring is</p><p>not very meaningful. Huawei can monitor the energy consumption of each device through rPDU,</p><p>but does not monitor the CPU.</p><p>B. Schneider uses CFD simulation to monitor temperature. However, the CFD software</p><p>simulation technology used by Schneider is used to predict incompressible fluids. It is only</p><p>accurate when the pressure difference is less than 5%. It is not suitable for data centers. The</p><p>temperature cloud map provided by Huawei is more accurate and real-time.</p><p>C. Schneider and Vertiv both have advantages in digital O&M. Huawei NetEco uses intelligent</p><p>operations to defend itself against competition.</p><p>D. Compared with other competitors in the same industry, Huawei's network security and</p><p>A/energy saving are its top advantages.</p><p>Answer: ABD</p><p>56. What are the three-in-one access control methods of Fusionmodule2000? (Multiple choice)</p><p>A. Password</p><p>B. Fingerprint</p><p>C. Credit card</p><p>Answer: ABC</p><p>57. What is the core idea of Huawei's icooling concept?</p><p>A. Control the air conditioner via iPhone</p><p>B. LOL1L2 layer linkage, faster demand and more accurate feedback</p><p>C. Refrigeration</p><p>D. Collaborate with Apple to solve refrigeration problems</p><p>Answer: B</p><p>58. What are the certifications for FusionModule500 & FusionModule800? (Multiple choice)</p><p>A. Air conditioner: CCC/CE/REACH/ROHS</p><p>B. Integrated cabinet: CE/REACH/ROHS</p><p>C. Air conditioner: REACH/ROHS</p><p>D. Integrated cabinet: CE/CCC/ROHS</p><p>Answer: ABCD</p><p>59. The NetEco6000 management system can provide a temperature cloud map function to</p><p>identify hot and cold spots in the computer room. How many layers of temperature cloud maps</p><p>12 / 18</p><p>does the temperature cloud map support? (Multiple choice)</p><p>A. Single layer</p><p>B. Double layer</p><p>C. Three layers</p><p>D. Four layers</p><p>Answer: ABC</p><p>60. UPS5000-E-75K half-height modular UPS modules can be sold in bulk or non-bulk form.</p><p>A. True</p><p>B. False</p><p>Answer: A</p><p>61. What line-in methods does UPS5000-A-400/500K support?</p><p>A. Downstream line</p><p>B. Upper line</p><p>C. Up and down wiring compatible</p><p>Answer: C</p><p>62. Which of the following alarm functions does the main circuit of PDU800 power distribution</p><p>cabinet have? (Multiple choice)</p><p>A. Current high value over-limit alarm</p><p>B. Overvoltage alarm</p><p>C. Main circuit power failure</p><p>D. Frequency Abnormality</p><p>E. Undervoltage alarm</p><p>Answer: ABCDE</p><p>63. UPS5000-E only needs to be equipped with () to easily realize the 2N power supply system,</p><p>which is simple and convenient to operate?</p><p>A. BSC cable</p><p>B. Synchronous Controller</p><p>C. BSC control panel</p><p>D. Parallel card</p><p>Answer: A</p><p>64. Which of the following UPS500O-E standard communication methods? (Multiple choice)</p><p>13 / 18</p><p>A. Dry contact</p><p>B. RS485</p><p>C. RS232</p><p>D.SNMP</p><p>Answer: ABD</p><p>65. What is the power supply architecture of the new row-level half-cabinet chilled water?</p><p>A. Single power supply</p><p>B. Dual power supply</p><p>C. AB are both correct</p><p>D. Others</p><p>Answer: C</p><p>66. What kind of inlet and outlet wiring methods can the FusionModule2000 integrated power</p><p>distribution cabinet implement?</p><p>A. Down-in and down-out</p><p>B. Upper inlet and outlet</p><p>C. Up-line in and down-line out</p><p>D. Lower inlet and upper outlet</p><p>Answer: B</p><p>67. UPS5000-S power module capacity is 50kVA, height is 2U, the highest power density in the</p><p>industry</p><p>A. True</p><p>B. False</p><p>Answer: B</p><p>68. Which of the following is the UPS used by FusionPower (prefabricated power module)?</p><p>A. UPS5000-E</p><p>B. UPS5000-A</p><p>C. UPS5000-H</p><p>D. PS5000-s</p><p>Answer: C</p><p>69. FusionModule800 connected pipes within 30m do not need to be charged with refrigerant on</p><p>site.</p><p>14 / 18</p><p>A. True</p><p>B. False</p><p>Answer: A</p><p>70. UPS5000-E 100kVA, which of the following input switches is most suitable for the machine?</p><p>A. 125A</p><p>B. 80A</p><p>C. 160A</p><p>D. 200A</p><p>Answer: D</p><p>71. Which of the following statements about battery intelligent management in UPS5000-A is</p><p>correct? (Multiple choice)</p><p>A. Support battery temperature compensation</p><p>B. Support battery sleep</p><p>C. The number of battery cells is adjustable</p><p>D. Intelligent floating charge conversion</p><p>Answer: ABCD</p><p>72. What is the input power factor (full load) of UPS5000-A that can effectively reduce the</p><p>pollution to the power grid and reduce the investment in the front-stage power distribution?</p><p>A. 1</p><p>B. >0.99</p><p>C. >0.98</p><p>Answer: B</p><p>73. iBattery intelligent battery management can monitor the parameters of a single battery in</p><p>detail. What are these parameters? (Multiple choice)</p><p>A. Electric current</p><p>B. Voltage</p><p>C. Internal resistance</p><p>D. Temperature</p><p>Answer: ABCD</p><p>74. How many power modules does the FusionModule2000 integrated UPS50K model support</p><p>at most?</p><p>15 / 18</p><p>A. 2 25K modules</p><p>B. 3 25K modules</p><p>C. 2 50K modules</p><p>D. 3 50K modules</p><p>Answer: B</p><p>75. If UPS5000-A-400/500K is equipped with a set of 40 12V batteries, how many battery</p><p>inspection meters are needed?</p><p>A. 0</p><p>B. 2</p><p>C. 3</p><p>D. 40</p><p>Answer: B</p><p>76. Class B machine rooms need to be equipped with generator sets.</p><p>A. True</p><p>B. False</p><p>Answer: A</p><p>77. Which of the typical configurations of FusionModule500 are standard?</p><p>A. Water immersion, smoke detection, temperature and humidity, door magnet</p><p>B. Water immersion, smoke detection, temperature and humidity, mobile phone APP</p><p>C. Flood, smoke, SMS alert, video</p><p>Answer: A</p><p>78. What is the maximum IT power supported by the Fusionmodule2000 precision power</p><p>distribution cabinet?</p><p>A. 125KW</p><p>B. 145KW (integrated power distribution cabinet)</p><p>C. 235KW</p><p>D. None</p><p>Answer: C</p><p>79. What is the maximum IT load supported by FusionModule2000 integrated UPS?</p><p>A. 50kw</p><p>B. 125kW</p><p>16 / 18</p><p>C. 150kW</p><p>D. 75kW</p><p>Answer: B</p><p>80. NetEco management</p><p>system can be deployed on () virtual machine software, saving the</p><p>purchase of servers through virtualization deployment?</p><p>A. Ms Hyper-v</p><p>B. VMware</p><p>C. KVM</p><p>D. Parallels</p><p>Answer: B</p><p>81. FusionModule1000AV2R3 version customized spray coating can meet UL120min fire</p><p>resistance requirements.</p><p>A. True</p><p>B. False</p><p>Answer: A</p><p>17 / 18</p><p>https://www.certqueen.com/promotion.asp</p><p>More Hot Exams are available.</p><p>350-401 ENCOR Exam Dumps</p><p>350-801 CLCOR Exam Dumps</p><p>200-301 CCNA Exam Dumps</p><p>Powered by TCPDF (www.tcpdf.org)</p><p>18 / 18</p><p>https://www.certqueen.com/350-401.html</p><p>https://www.certqueen.com/350-801.html</p><p>https://www.certqueen.com/200-301.html</p><p>http://www.tcpdf.org</p>