Baixe o app para aproveitar ainda mais
Prévia do material em texto
06/07/2021 Configurar RSLinx Gateway em um PC remoto - Bryce Automation bryceautomation.com/index.php/2020/12/10/rslinx-gateway/ 1/6 Procurar … Procurar Postagens recentes Arquivos Node-Red com ControlLogix› Arduino com Allen-Bradley DF1› Portas lógicas comuns› Organizando Objetos do FactoryTalk View› 74CH93 Contador Binário› Maio de 2021› Março de 2021› Fevereiro de 2021› Janeiro de 2021› Dezembro de 2020› Novembro de 2020› Setembro de 2020› Agosto de 2020› Junho de 2020› Março de 2020› Fevereiro de 2020› Janeiro de 2020› Dezembro de 2019› Novembro de 2019› Outubro de 2019› Setembro de 2019› Abril de 2019› Março de 2019› Dezembro de 2018› Novembro de 2018› Outubro de 2018› Setembro de 2018› Julho de 2018› Home » ControlLogix » Gateway RSLinx �� http://bryceautomation.com/index.php/2021/05/29/node-red-with-controllogix/ http://bryceautomation.com/index.php/2021/03/27/arduino-with-allen-bradley-df1/ http://bryceautomation.com/index.php/2021/02/26/common-logic-gates/ http://bryceautomation.com/index.php/2021/02/17/arranging-factorytalk-view-objects/ http://bryceautomation.com/index.php/2021/02/16/74ch93-binary-counter/ http://bryceautomation.com/index.php/2021/05/ http://bryceautomation.com/index.php/2021/03/ http://bryceautomation.com/index.php/2021/02/ http://bryceautomation.com/index.php/2021/01/ http://bryceautomation.com/index.php/2020/12/ http://bryceautomation.com/index.php/2020/11/ http://bryceautomation.com/index.php/2020/09/ http://bryceautomation.com/index.php/2020/08/ http://bryceautomation.com/index.php/2020/06/ http://bryceautomation.com/index.php/2020/03/ http://bryceautomation.com/index.php/2020/02/ http://bryceautomation.com/index.php/2020/01/ http://bryceautomation.com/index.php/2019/12/ http://bryceautomation.com/index.php/2019/11/ http://bryceautomation.com/index.php/2019/10/ http://bryceautomation.com/index.php/2019/09/ http://bryceautomation.com/index.php/2019/04/ http://bryceautomation.com/index.php/2019/03/ http://bryceautomation.com/index.php/2018/12/ http://bryceautomation.com/index.php/2018/11/ http://bryceautomation.com/index.php/2018/10/ http://bryceautomation.com/index.php/2018/09/ http://bryceautomation.com/index.php/2018/07/ http://bryceautomation.com/ http://bryceautomation.com/index.php/category/controllogix/ http://bryceautomation.com/ 06/07/2021 Configurar RSLinx Gateway em um PC remoto - Bryce Automation bryceautomation.com/index.php/2020/12/10/rslinx-gateway/ 2/6 RSLinx Gateway 10 de dezembro de 2020 em ControlLogix / PLC-5 / comunicação marcada SLC500 / gateway / RSLinx por Ricky Introdução ao RSLinx Gateway RSLinx Gateway é uma versão do RSLinx que permite acessar outros tipos de redes. Por exemplo, você terá um computador que possui um 1784-KTx ou 1784-PKTx. Este computador está conectado a uma rede Data Highway Plus. Este computador também está na rede Ethernet. Você poderá acessar a rede Data Highway Plus pela Categorias Maio de 2018› Março de 2018› Novembro de 2017› Outubro de 2017› Setembro de 2017› Julho de 2017› Junho de 2017› Maio de 2017› Abril de 2017› Março de 2017› Fevereiro de 2017› Dezembro 2016› Avançado› Arduino e outros microprocessadores› Principiante› ControlLogix› Criação› Experimentos› EZPLC› FactoryTalk View ME› FactoryTalk View SE› Tecnologia da Informação› Intermediário› Misc. Documentos› Movimento› Nó-Vermelho› PlantPAx› PLC-5› SLC500› �� http://bryceautomation.com/index.php/2020/12/10/ http://bryceautomation.com/index.php/category/controllogix/ http://bryceautomation.com/index.php/category/plc-5/ http://bryceautomation.com/index.php/tag/communication/ http://bryceautomation.com/index.php/category/slc500/ http://bryceautomation.com/index.php/tag/gateway/ http://bryceautomation.com/index.php/tag/rslinx/ http://bryceautomation.com/index.php/author/ricky/ http://bryceautomation.com/index.php/2018/05/ http://bryceautomation.com/index.php/2018/03/ http://bryceautomation.com/index.php/2017/11/ http://bryceautomation.com/index.php/2017/10/ http://bryceautomation.com/index.php/2017/09/ http://bryceautomation.com/index.php/2017/07/ http://bryceautomation.com/index.php/2017/06/ http://bryceautomation.com/index.php/2017/05/ http://bryceautomation.com/index.php/2017/04/ http://bryceautomation.com/index.php/2017/03/ http://bryceautomation.com/index.php/2017/02/ http://bryceautomation.com/index.php/2016/12/ http://bryceautomation.com/index.php/category/advanced/ http://bryceautomation.com/index.php/category/arduino-other-microprocessors/ http://bryceautomation.com/index.php/category/beginner/ http://bryceautomation.com/index.php/category/controllogix/ http://bryceautomation.com/index.php/category/creation/ http://bryceautomation.com/index.php/category/experiments/ http://bryceautomation.com/index.php/category/ezplc/ http://bryceautomation.com/index.php/category/factorytalk-view-me/ http://bryceautomation.com/index.php/category/factorytalk-view-se/ http://bryceautomation.com/index.php/category/information-technology/ http://bryceautomation.com/index.php/category/intermediate/ http://bryceautomation.com/index.php/category/misc-documents/ http://bryceautomation.com/index.php/category/motion/ http://bryceautomation.com/index.php/category/node-red/ http://bryceautomation.com/index.php/category/plantpax/ http://bryceautomation.com/index.php/category/plc-5/ http://bryceautomation.com/index.php/category/slc500/ http://bryceautomation.com/ 06/07/2021 Configurar RSLinx Gateway em um PC remoto - Bryce Automation bryceautomation.com/index.php/2020/12/10/rslinx-gateway/ 3/6 Ethernet. Como o custo de um módulo 1784-KTx (ou qualquer outro módulo de rede) é muito alto, você economizará dinheiro a longo prazo. Você também melhora sua �exibilidade para acessar a rede Data Highway Plus de potencialmente qualquer lugar na planta. Con�gure o Gateway No computador Gateway, certi�que-se de ter uma ativação RSLinx Gateway instalada. A barra de título do RSLinx deve re�etir isso. Além disso, con�gure todos os drivers necessários para suas placas de comunicação. Neste ponto, em “Comunicações”, escolha con�gurar o gateway. Certi�que-se de marcar “Enable RSLinx Gateway”, então escolha “Apply” e “OK”. �� http://bryceautomation.com/ 06/07/2021 Configurar RSLinx Gateway em um PC remoto - Bryce Automation bryceautomation.com/index.php/2020/12/10/rslinx-gateway/ 4/6 Finalmente, reinicie o RSLinx. Como o RSLinx às vezes é executado como um serviço, sempre reinicializo o computador, se possível. Con�gure o cliente Agora que o gateway está con�gurado, você está pronto para con�gurar o driver no cliente. O cliente não precisa de uma ativação instalada para acessar o gateway. Clique em “Comunicação | Con�gure Drivers ”e escolha“ Remote Devices via RSLinx Gateway. Se a sua máquina de gateway não for descoberta automaticamente, digite o endereço IP da máquina de gateway e clique em “Procurar”. Você verá os drivers disponíveis no PC do Gateway. Clique no driver ao qual deseja se conectar e pressione OK. Neste ponto, se você não conseguir ver nenhum driver na máquina do gateway, certi�que-se de veri�car o �rewall em ambos os PCs. Certi�que-se também de que a máquina de gateway esteja na mesma rede do seu PC. �� http://bryceautomation.com/ 06/07/2021 Configurar RSLinx Gateway em um PC remoto - Bryce Automation bryceautomation.com/index.php/2020/12/10/rslinx-gateway/ 5/6 Depois de pressionar “Aplicar” e “OK”, vá para a tela RSWho do seu cliente. Destaque o driver e você verá todos os dispositivos na rede Data Highway Plus. Você está pronto para acessar o RSLogix para se comunicar com qualquer processador na rede! Para obter mais informações, visite a página de categoria do ControlLogix! - Ricky Bryce � Deixe um comentário Seu endereço de e-mail não será publicado. Os campos obrigatórios estão marcados com * �� http://bryceautomation.com/index.php/category/controllogix/ http://bryceautomation.com/index.php/category/controllogix/ http://bryceautomation.com/ 06/07/2021 Configurar RSLinxGateway em um PC remoto - Bryce Automation bryceautomation.com/index.php/2020/12/10/rslinx-gateway/ 6/6 ← Ponto de interrogação amarelo no RSLinx Animação da Biblioteca FactoryTalk View → Comente Nome * Email * Local na rede Internet WC Captcha quarenta e seis + = cinquenta e dois Postar Comentário · © 1999 Bryce Automation · reCAPTCHA I'm not a robot Privacy - Terms P ó s - n a v e g a ç ã o �� http://bryceautomation.com/index.php/2020/12/09/yellow-question-mark-in-rslinx/ http://bryceautomation.com/index.php/2020/12/10/factorytalk-view-library-animation/ http://home_url/ https://www.google.com/intl/en/policies/privacy/ https://www.google.com/intl/en/policies/terms/ http://bryceautomation.com/
Compartilhar