Buscar

FERRERIA_LTDA _PRENSA_BIMANUAL em ladder

Prévia do material em texto

Totally Integrated
Automation Portal
ferreira ltda,prensa bimanual / PLC_1 [CPU 1214C DC/DC/Rly] / Program blocks
Main [OB1]
Main Properties
General
Name Main Number 1 Type OB Language LAD
Numbering Automatic
Information
Title "Main Program Sweep (Cy‐
cle)"
Author Comment Family
Version 0.1 User-defined ID
Main
Name Data type Default value Comment
Input
Initial_Call Bool Initial call of this OB
Remanence Bool =True, if remanent data are available
Temp
Constant
Network 1: biblioteca factory io
"MHJ-PLC-Lab-Function-S71200"
%FC9000%FC9000
EN ENOEN ENO
Network 2: HBILITA GERAL
Totally Integrated
Automation Portal
"SG CHAVE 
GERAL"
%I0.0%I0.0
"DB".HABILITA
Network 3: AVANCA CILINDRO BAIXA PESSAO
"DB".HABILITA "S3 PEDAL"
%I0.3%I0.3
"SAX AVANCA"
%Q0.1%Q0.1
Network 4: CONDICAO DE VALVULA ALTA PRESSAO
Totally Integrated
Automation Portal
TON
Time
TON
Time
"DB".HABILITA "SAX AVANCA"
%Q0.1%Q0.1
"S1 BOTAO 1"
%I0.1%I0.1
"S2 BOTAO 2"
%I0.2%I0.2
"DB".
"DESABILITA 
TEMPO"
"X1 SENSOR 
FINAL"
%I0.5%I0.5
"X0 SENSOR 
INICIAL"
%I0.4%I0.4
"SAP ALTA 
PRESSAO"
%Q0.0%Q0.0
"S1 BOTAO 1"
%I0.1%I0.1 "SAP ALTA 
PRESSAO"
%Q0.0%Q0.0
"IEC_Timer_0_DB"
%DB2%DB2
T#1S T#0ms
"S2 BOTAO 2"
%I0.2%I0.2 "SAP ALTA 
PRESSAO"
%Q0.0%Q0.0
"IEC_Timer_0_
DB_1"
%DB3%DB3
T#1S T#0ms
"IEC_Timer_0_
DB".Q
"IEC_Timer_0_
DB_1".Q
"DB".
"DESABILITA 
TEMPO"
IN
PT
Q
ET
Time
IN
PT
Q
ET
Time
IN
PT
Q
ET
Time
IN
PT
Q
ET
Time
Network 5: RETORNO DO CILINDRO
"DB".HABILITA "S3 PEDAL"
%I0.3%I0.3 "X0 SENSOR 
INICIAL"
%I0.4%I0.4
"SRX RETORNO"
%Q0.2%Q0.2

Continue navegando