What is the minimum height for the open end of the ventilation column and fan tube, according to ABNT NBR 8160:1999? The open end of the ventilati...

What is the minimum height for the open end of the ventilation column and fan tube, according to ABNT NBR 8160:1999?

The open end of the ventilation column and fan tube must be at a minimum height of 2 meters above the terrace, in the case of a slab used for purposes other than covering.
The open end of the ventilation column and fan tube must be at a minimum height of 4 meters from any window, door or ventilation gap, unless raised at least 1 meter from the verges of the respective gaps.
a) Only item I is correct.
b) Only item II is correct.
c) Both items are correct.
d) Both items are incorrect.

Essa pergunta também está no material:

AULA 3 - LIVRO
19 pág.

Instalações Hidraúlicas Centro Universitário do Norte (UniNorte)Centro Universitário do Norte (UniNorte)

💡 1 Resposta

User badge image

Ed Verified user icon

De acordo com a ABNT NBR 8160:1999, a altura mínima para a extremidade aberta da coluna de ventilação e do tubo de exaustão deve ser de 2 metros acima do terraço, no caso de uma laje utilizada para fins diferentes de cobertura. Além disso, a extremidade aberta da coluna de ventilação e do tubo de exaustão deve estar a uma altura mínima de 4 metros de qualquer janela, porta ou abertura de ventilação, a menos que seja elevada pelo menos 1 metro das bordas das respectivas aberturas. Portanto, a alternativa correta é a letra C) Ambos os itens estão corretos.