Baixe o app para aproveitar ainda mais
Prévia do material em texto
www.cdvgroup.com All the specifications on this document (photos, drawing, features and dimensions) could be changed without prior notice. Printed in Canada - Ref: CDVI_DGLP_DGLI_Readers_IE Manufacturing Access Control since 1985 CDVI (Headquarters/Siège social) FRANCE Tel: +33 (0)1 48 91 01 02 Fax: +33 (0)1 48 91 21 21 CDV AMERICAS CANADA Tel: +1 (450) 682 7945 Fax: +1 (450) 682 9590 CDV BENELUX BELGIUM Tel: +32 (0)5 662 02 50 Fax: +32 (0)5 662 02 55 CDV CH SWITZERLAND Tel: +41 (0)21 882 18 41 Fax : +41 (0)21 882 18 42 CDV CHINA CHINA Tel: +86 (0)10 87664065 Fax: +86 (0)10 87664165 CDV IBÉRICA SPAIN Tel: +34 936 916 551 Fax: +34 935 801 278 CDV ITALIA ITALIA Tel: +39 0331 97 38 08 Fax: +39 0331 97 39 70 CDV MAROC MOROCCO Tel : +212 (0)22 48 09 40 Fax : +212 (0)22 48 34 69 CDV SWEDEN SWEDEN Tel: +46 (0)33 20 55 50 Fax: +46 (0)33 20 55 51 CDV UK Ltd UNITED KINGDOM Tel: +44 (0)1628 531300 Fax : +44 (0)1628 531003 DIGIT FRANCE Tel : +33 (0)1 41 71 06 85 Fax : +33 (0)1 41 71 06 86 LA GACHE ELECTRIQUE FRANCE Tel: +33 (0)3 88 77 32 82 Fax: +33 (0)3 88 77 85 02 PROCOFI FRANCE Tel: +33 (0)1 41 83 04 90 Fax: +33 (0)1 41 83 04 91 TECHNO EM FRANCE Tel: +33 (0)4 42 96 58 73 Fax: +33 (0)4 42 96 45 77 INSTALLATION MANUAL Indoor/Outdoor Wiegand Proximity Readers DGLP WLC DGLP FN WLC DGLI WLC DGLI F WLC w w w. c d v g r o u p . c o m Installation Manual w w w. c d v g r o u p . c o m Wiegand Proximity Readers 98 mm (3.9") 77 m m ( 3" ) 19,5 mm (.75") 14 0 m m ( 5. 5" ) 35 mm (1.4") 21,5 mm (.8") 104 mm (4.1") 8 0 .5 m m ( 3 .5 ") 23 mm (.9") 1 4 0 m m ( 5 .5 ") 42 mm (1.7") 23 mm (.9") PRODUCT OVERVIEW: The DGLP WLC and DGLI WLC are two Wiegand Proximity readers, availa- ble as standard size and narrow style (DGLP FN WLC et DGLI F WLC). Both readers are sealed with epoxy, therefore they are suitable for external use and have high resistance to vandalism. DGLl WLC DGLP FN WLCDGLP WLC DGLI F WLC 53 -25°C to +70°C Measure and mark the center lines to determine the reader position. Drill the fixing screw holes (Diametre: 4MM for the mounting plate and 6MM for the reader). Drill the wiring access area. DGLI F WLC Insert the brass anchors in the mounting holes, connect the cable to the connectors, then fasten the reader with the DIAX® screws using the DIAX® spanner. Make sure that the varistor is connected on the lock (refer to page 2 «Recommendations»). DGLP FN WLC Insert the plastic anchors in the mounting holes, connect the cable to the terminal block, then fasten the reader with the wooden screws. Put the covers on top of the reader. Make sure that the varistor is connected on the lock (refer to page 2 «Recommendations»). Optional (MPLATE) Single gang box mounting plate for the DGLP FN WLC mullion polycarbonate proximity reader. Ref : DGLP FN WLC and DGLI F WLC 4 1 2 3 w w w. c d v g r o u p . c o m Installation Manual w w w. c d v g r o u p . c o m Wiegand Proximity Readers • Indoor / outdoor application • Selectable Wiegand output, 26, 30 or 44-bits • LED and built-in buzzer (internal or external mode) • Potted electronics • Input voltage: 12V DC • Consumption: 100mA RECOMMENDATIONS: CONTENTS: Recommended cables 4 twisted pairs 0.6 MM. Suggested power supplies These power supplies are recommended with these Wiegand readers: - ARD12 - BS60 Optional Single gang box mounting plate for the DGLP FN WLC reader (Ref: MPLATE). Important To protect the device from back - emf do not forget to mount the varistor on the lock in parallel. Environment If the readers are mounted in a humid area or close to a sea shore, we recommend applying a varnish on the connections of the cable to avoid oxidation. Varistor Diax® security tool Diax® security screw Brass anchor Right cover Left cover Plastic anchor Wood screw 3 x 40 mm DGLI WLC & DGLI F WLC 1 1 2 2 - - - - DGLP WLC & DGLP F WLC 1 - - - 2 2 2 2 FEATURES: Measure and mark the center lines to determine the reader position. Drill the fixing screw holes (Diametre: 4MM for the mounting plate and 6MM for the reader). Drill the wiring access area. DGLI WLC Insert the brass anchors in the mounting holes, connect the cable to the terminal block, then fasten the reader with the DIAX® screws using the DIAX® spanner. Make sure that the varistor is connected on the lock (refer to page 2 «Recommendations»). DGLP WLC Insert the plastic anchors in the mounting holes, connect the cable to the terminal block, Then fasten the reader with the wooden screws Leave an area to access the cable to make the wiring). Put the covers on top of the reader. Make sure that the varistor is connected on the lock (refer to page 2 «Recommendations»). MOUNTING INSTRUCTIONS: 1 2 3 Ref : DGLP WLC and DGLI WLC w w w. c d v g r o u p . c o m Installation Manual w w w. c d v g r o u p . c o m Wiegand Proximity Readers • Indoor / outdoor application • Selectable Wiegand output, 26, 30 or 44-bits • LED and built-in buzzer (internal or external mode) • Potted electronics • Input voltage: 12V DC • Consumption: 100mA RECOMMENDATIONS: CONTENTS: Recommended cables 4 twisted pairs 0.6 MM. Suggested power supplies These power supplies are recommended with these Wiegand readers: - ARD12 - BS60 Optional Single gang box mounting plate for the DGLP FN WLC reader (Ref: MPLATE). Important To protect the device from back - emf do not forget to mount the varistor on the lock in parallel. Environment If the readers are mounted in a humid area or close to a sea shore, we recommend applying a varnish on the connections of the cable to avoid oxidation. Varistor Diax® security tool Diax® security screw Brass anchor Right cover Left cover Plastic anchor Wood screw 3 x 40 mm DGLI WLC & DGLI F WLC 1 1 2 2 - - - - DGLP WLC & DGLP F WLC 1 - - - 2 2 2 2 FEATURES: Measure and mark the center lines to determine the reader position. Drill the fixing screw holes (Diametre: 4MM for the mounting plate and 6MM for the reader). Drill the wiring access area. DGLI WLC Insert the brass anchors in the mounting holes, connect the cable to the terminal block, then fasten the reader with the DIAX® screws using the DIAX® spanner. Make sure that the varistor is connected on the lock (refer to page 2 «Recommendations»). DGLP WLC Insert the plastic anchors in the mounting holes, connect the cable to the terminal block, Then fasten the reader with the wooden screws Leave an area to access the cable to make the wiring). Put the covers on top of the reader. Make sure that the varistor is connected on the lock (refer to page 2 «Recommendations»). MOUNTING INSTRUCTIONS: 1 2 3 Ref : DGLP WLC and DGLI WLC w w w. c d v g r o u p . c o m Installation Manual w w w. c d v g r o u p . c o m Wiegand Proximity Readers 98 mm (3.9") 77 m m ( 3" ) 19,5 mm (.75") 14 0 m m ( 5. 5" ) 35 mm (1.4") 21,5 mm (.8") 104 mm (4.1") 8 0 .5 m m ( 3 .5 ") 23 mm (.9") 1 4 0 m m ( 5 .5 ") 42 mm (1.7") 23 mm (.9") PRODUCT OVERVIEW: The DGLP WLC and DGLI WLC are two Wiegand Proximity readers, availa- ble as standard size and narrow style (DGLP FN WLC et DGLI F WLC). Both readers are sealed with epoxy, therefore they are suitable for external use and have high resistance to vandalism. DGLP WLC DGLP FN WLCDGLI WLC DGLI F WLC 53 -25°C to +70°C Measure and mark the center lines to determine the reader position. Drill the fixing screw holes (Diametre: 4MM for the mounting plate and 6MM for the reader). Drill the wiring access area. DGLI F WLC Insert the brass anchors in the mounting holes, connect the cable to the connectors, then fasten the reader with the DIAX® screws using the DIAX® spanner. Make sure that the varistor is connected on the lock (refer to page 2 «Recommendations»). DGLP FN WLC Insert the plastic anchors in the mounting holes, connect the cable to the terminal block, thenfasten the reader with the wooden screws. Put the covers on top of the reader. Make sure that the varistor is connected on the lock (refer to page 2 «Recommendations»). Optional (MPLATE) Single gang box mounting plate for the DGLP FN WLC mullion polycarbonate proximity reader. Ref : DGLP FN WLC and DGLI F WLC 4 1 2 3 w w w. c d v g r o u p . c o m Installation Manual w w w. c d v g r o u p . c o m Wiegand Proximity Readers JUMPER SETTING AND WIRING DIAGRAM: 26-bit Wiegand ouput (Default) +5V (Default) +12V 30-bit Wiegand ouput 44-bit Wiegand ouput 1 = ON: External Buzzer Activation 2 = ON: External LED Activation 1 = OFF: Internal Buzzer Activation (Default) 2 = OFF: Internal LED Activation (Default) BUZZER AND LED DIPSWITCH SETTINGS ON 1 2 ON 1 2 DIPSWITCH setting will take effect at power up only DGLI F WLC DGLP FN WLC ON 1 2 ON 1 2 PULL UPS JUMPER SETTING WIEGAND OUTPUT JUMPER SETTING CT-V900-A 2-Door Controller DO GND D1 12V OUT1 OUT2 OUT5 GREEN BLACK WHITE RED YELLOW (green LED) ORANGE (red LED) BROWN (buzzer) Blue (Clock) Not applicable with Centaur System Reader wiring is shown with a 2-door controller CT-V900-A and default jumper setting of the reader (see above). It may differ from other controllers. Please consult the manufacturer for details. DGLP FN WLC DGLI F WLC CAT5 CABLE (unshield 4 twisted paire cable) ON 1 2 H D0 D1 B- RV+ 26-bit Wiegand ouput (Default) +5V (Default) +12V 30-bit Wiegand ouput 44-bit Wiegand ouput 1 = ON: External Buzzer Activation 2 = ON: External LED Activation 1 = OFF: Internal Buzzer Activation (Default) 2 = OFF: Internal LED Activation (Default) ON 1 2 ON 1 2 DIPSWITCH setting will take effect at power up only ON 1 2 H D0 D1 B- RV+ DGLP WLC or DGLI WLC BUZZER AND LED DIPSWITCH SETTINGS PULL UPS JUMPER SETTING WIEGAND OUTPUT JUMPER SETTING CT-V900-A 2-Door Controller CAT5 CABLE (unshield 4 twisted paire cable) DO GND D1 12V OUT1 OUT2 OUT5 DO - D1 + V (green LED) R (red LED) B (buzzer) H (Clock) Not applicable with Centaur System Reader wiring is shown with a 2-door controller CT-V900-A and default jumper setting of the reader (see above). It may differ from other controllers. Please consult the manufacturer for details. or DGLP WLC DGLI WLC w w w. c d v g r o u p . c o m Installation Manual w w w. c d v g r o u p . c o m Wiegand Proximity Readers JUMPER SETTING AND WIRING DIAGRAM: 26-bit Wiegand ouput (Default) +5V (Default) +12V 30-bit Wiegand ouput 44-bit Wiegand ouput 1 = ON: External Buzzer Activation 2 = ON: External LED Activation 1 = OFF: Internal Buzzer Activation (Default) 2 = OFF: Internal LED Activation (Default) BUZZER AND LED DIPSWITCH SETTINGS ON 1 2 ON 1 2 DIPSWITCH setting will take effect at power up only DGLI F WLC DGLP FN WLC ON 1 2 ON 1 2 PULL UPS JUMPER SETTING WIEGAND OUTPUT JUMPER SETTING CT-V900-A 2-Door Controller DO GND D1 12V OUT1 OUT2 OUT5 GREEN BLACK WHITE RED YELLOW (green LED) ORANGE (red LED) BROWN (buzzer) Blue (Clock) Not applicable with Centaur System Reader wiring is shown with a 2-door controller CT-V900-A and default jumper setting of the reader (see above). It may differ from other controllers. Please consult the manufacturer for details. DGLP FN WLC DGLI F WLC CAT5 CABLE (unshield 4 twisted paire cable) ON 1 2 H D0 D1 B- RV+ 26-bit Wiegand ouput (Default) +5V (Default) +12V 30-bit Wiegand ouput 44-bit Wiegand ouput 1 = ON: External Buzzer Activation 2 = ON: External LED Activation 1 = OFF: Internal Buzzer Activation (Default) 2 = OFF: Internal LED Activation (Default) ON 1 2 ON 1 2 DIPSWITCH setting will take effect at power up only ON 1 2 H D0 D1 B- RV+ DGLP WLC or DGLI WLC BUZZER AND LED DIPSWITCH SETTINGS PULL UPS JUMPER SETTING WIEGAND OUTPUT JUMPER SETTING CT-V900-A 2-Door Controller CAT5 CABLE (unshield 4 twisted paire cable) DO GND D1 12V OUT1 OUT2 OUT5 DO - D1 + V (green LED) R (red LED) B (buzzer) H (Clock) Not applicable with Centaur System Reader wiring is shown with a 2-door controller CT-V900-A and default jumper setting of the reader (see above). It may differ from other controllers. Please consult the manufacturer for details. or DGLP WLC DGLI WLC www.cdvgroup.com All the specifications on this document (photos, drawing, features and dimensions) could be changed without prior notice. Printed in Canada - Ref: CDVI_DGLP_DGLI_Readers_IE Manufacturing Access Control since 1985 CDVI (Headquarters/Siège social) FRANCE Tel: +33 (0)1 48 91 01 02 Fax: +33 (0)1 48 91 21 21 CDV AMERICAS CANADA Tel: +1 (450) 682 7945 Fax: +1 (450) 682 9590 CDV BENELUX BELGIUM Tel: +32 (0)5 662 02 50 Fax: +32 (0)5 662 02 55 CDV CH SWITZERLAND Tel: +41 (0)21 882 18 41 Fax : +41 (0)21 882 18 42 CDV CHINA CHINA Tel: +86 (0)10 87664065 Fax: +86 (0)10 87664165 CDV IBÉRICA SPAIN Tel: +34 936 916 551 Fax: +34 935 801 278 CDV ITALIA ITALIA Tel: +39 0331 97 38 08 Fax: +39 0331 97 39 70 CDV MAROC MOROCCO Tel : +212 (0)22 48 09 40 Fax : +212 (0)22 48 34 69 CDV SWEDEN SWEDEN Tel: +46 (0)33 20 55 50 Fax: +46 (0)33 20 55 51 CDV UK Ltd UNITED KINGDOM Tel: +44 (0)1628 531300 Fax : +44 (0)1628 531003 DIGIT FRANCE Tel : +33 (0)1 41 71 06 85 Fax : +33 (0)1 41 71 06 86 LA GACHE ELECTRIQUE FRANCE Tel: +33 (0)3 88 77 32 82 Fax: +33 (0)3 88 77 85 02 PROCOFI FRANCE Tel: +33 (0)1 41 83 04 90 Fax: +33 (0)1 41 83 04 91 TECHNO EM FRANCE Tel: +33 (0)4 42 96 58 73 Fax: +33 (0)4 42 96 45 77 INSTALLATION MANUAL Indoor/Outdoor Wiegand Proximity Readers DGLP WLC DGLP FN WLC DGLI WLC DGLI F WLC
Compartilhar