Measurement Guide Spectrum Analyzer for Anritsu RF and Microwave Handheld Instruments BTS Master™, Site Master™, Spectrum Master™, Cell Master™, LMR Master™, VNA Master™ Spectrum Analyzer Included Preamplifier Option 8 Bias Tee Option 10 IQ Waveform Capture Option 24 Interference Analyzer Option 25 Channel Scanner Option 27 CW Generator Option 28 Zero-Span IF Output Option 89 Gated Sweep Option 90 Coverage Mapping Option 431 Electromagnetic Field (EMF) Option 444 AM/FM/PM Analyzer Option 509 Note Not all instrument models offer every option or every measurement within a given option. Refer to the Technical Data Sheet of your instrument for available options and supported measurements. Anritsu Company 490 Jarvis Drive Morgan Hill, CA 95037-2809 USA http://www.anritsu.com Part Number: 10580-00349 Revision: K Published: August 2016 Copyright 2016 Anritsu Company Trademark Acknowledgments BTS Master, Site Master, Spectrum Master, Cell Master, LMR Master, VNA Master, and Anritsu easyMap Tools are trademarks of Anritsu Company. Notice Anritsu Company has prepared this manual for use by Anritsu Company personnel and customers as a guide for the proper installation, operation and maintenance of Anritsu Company equipment and computer programs. The drawings, specifications, and information contained herein are the property of Anritsu Company, and any unauthorized use or disclosure of these drawings, specifications, and information is prohibited; they shall not be reproduced, copied, or used in whole or in part as the basis for manufacture or sale of the equipment or software programs without the prior written consent of Anritsu Company. Updates Updates, if any, can be downloaded from the Anritsu website at: http://www.anritsu.com For the latest service and sales contact information in your area, please visit: http://www.anritsu.com/contact-us Product Information, Compliance, and Safety Read the Handheld Instruments Product Information, Compliance, and Safety Guide (PN: 10100-00065) for important safety, legal, and regulatory notices before operating the equipment. For additional information and literature covering your product, visit the product page of your instrument and select the Library tab. Spectrum Analyzer MG PN: 10580-00349 Rev. K Contents-1 Table of Contents Chapter 1—General Information 1-1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1-2 Selecting a Measurement Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1-3 Contacting Anritsu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Chapter 2—Spectrum Analyzer 2-1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 2-2 General Measurement Setups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 2-3 Making Spectrum Analyzer Measurements . . . . . . . . . . . . . . . . . . . . . . . . 2-1 Setting Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 Setting Bandwidth Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 Setting Sweep Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 2-4 Resolution Bandwidth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8 2-5 Video Bandwidth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8 2-6 Sweep Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9 2-7 Attenuator Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9 2-8 Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10 2-9 Indications of Excessive Signal Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10 2-10 Preamplifier Measurement Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14 2-11 Field Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14 2-12 Field Strength . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-15 Antenna Calculations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-16 2-13 Occupied Bandwidth Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-17 2-14 Channel Power Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-19 Channel Power Measurement for GSM . . . . . . . . . . . . . . . . . . . . . . 2-19 2-15 Adjacent Channel Power Measurement . . . . . . . . . . . . . . . . . . . . . . . . . 2-21 2-16 EMF Measurement (Option 444) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-22 2-17 Out-of-Band Spurious Emission Measurements . . . . . . . . . . . . . . . . . . . 2-23 2-18 In-Band/Out-of-Channel Measurements . . . . . . . . . . . . . . . . . . . . . . . . . 2-25 2-19 AM/FM/SSB Demodulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-26 2-20 Carrier to Interference Ratio Measurement . . . . . . . . . . . . . . . . . . . . . . 2-27 2-21 Emission Mask (In-Band) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-30 Contents-2 PN: 10580-00349 Rev. K Spectrum Analyzer MG Table of Contents (Continued) 2-22 Spurious Emissions (Out-of-Band) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-31 Creating a New Spurious Emission Mask . . . . . . . . . . . . . . . . . . . . . . 2-31 Loading an Existing Mask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-33 Modifying an Existing Mask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-33 Spurious Emissions (Out-of-Band) Measurements . . . . . . . . . . . . . . . 2-35 2-23 Coverage Mapping (Option 431). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-37 2-24 IQ Waveform Capture (Option 24) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-38 Waveform Capture Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-38 Capturing a Waveform. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-39 2-25 Spectrum Analyzer Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-40 Marker Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-41 Measure Menu (1 of 5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-42 Measure Menu (2 of 5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-43 Measure Menu (3 of 5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-44 Measure Menu (4 of 5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-45 Measure Menu (5 of 5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-46 Sweep Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-47 Trace Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-48 Limit Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-48 Application Options Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-49 2-26 Freq (Frequency) Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-50 Freq (Frequency) Menu (Continued) . . . . . . . . . . . . . . . . . . . . . . . . . . 2-51 2-27 Frequency Menu (Freq 1/2) with Offset Function . . . . . . . . . . . . . . . . . . 2-52 Freq 2/2 Menu . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . 2-54 2-28 Amplitude Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-56 Units & Detection Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-57 2-29 Span Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-58 2-30 Zero Span IF BW Menu (Option 89) . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-59 2-31 BW (Bandwidth) Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-60 2-32 Marker Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-61 More Peak Options (Marker & Peak) Menu . . . . . . . . . . . . . . . . . . . . 2-62 Marker 2/2 Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-63 2-33 Sweep Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-64 Sweep Mode Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-65 Triggering Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-66 Trigger Source Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-67 Gate Setup Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-68 Spectrum Analyzer MG PN: 10580-00349 Rev. K Contents-3 Table of Contents (Continued) 2-34 Measure Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-69 Power and BW Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-70 Field Strength Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-71 OCC BW Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-72 Channel Power Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-73 ACPR Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-74 EMF Menu (Option 444) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-76 Masks and C/I Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-77 Emission Mask (In-Band) Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-78 Spurious Emissions (Out-of-Band) Menu . . . . . . . . . . . . . . . . . . . . . . 2-79 C/I Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-81 C/I Signal Type Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-82 AM/FM Demod 1/2 Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-83 Demod Type (AM/FM) Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-84 AM/FM Demod 2/2 (More) Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-85 Generator Menu (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-86 IQ Waveform Capture Menu (Option 24) . . . . . . . . . . . . . . . . . . . . . 2-87 IQ Capture Triggering Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-88 IQ Capture Save Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-88 IQ Capture Frequency/Amplitude Menu . . . . . . . . . . . . . . . . . . . . . . 2-89 Coverage Mapping Menu (Option 431) . . . . . . . . . . . . . . . . . . . . . . . . 2-90 2-35 Trace Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-91 Trace A Ops Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-93 Trace B Ops Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-94 Trace C Ops Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-95 2-36 Limit Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-96 Edit Menu (Limit) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-97 Edit Menu (Continued). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-98 Limit Move Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-99 Limit Envelope Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-100 Limit Advanced Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-102 2-37 Application Options Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-103 2-38 Other Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-103 Chapter 3—Interference Analyzer (Option 25) 3-1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 3-2 General Measurement Setups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 3-3 Spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 3-4 Spectrogram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 3-5 Signal Strength . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 3-6 Received Signal Strength Indicator (RSSI). . . . . . . . . . . . . . . . . . . . . . . . . 3-5 Contents-4 PN: 10580-00349 Rev. K Spectrum Analyzer MG Table of Contents (Continued) 3-7 Signal ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6 3-8 Interference Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9 Interference Mapping (Antenna Only) . . . . . . . . . . . . . . . . . . . . . . . . . 3-10 Interference Mapping (MA2700A and Antenna) . . . . . . . . . . . . . . . . . 3-14 Save the Mapping Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-19 3-9 Interference Analyzer (IA) Menu Maps . . . . . . . . . . . . . . . . . . . . . . . . . . 3-22 Measurements Menu (1 of 4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23 Measurements Menu (2 of 4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-24 Measurements Menu (3 of 4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-25 Measurements Menu (4 of 4). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-26 Marker Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-27 Sweep Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-28 Trace Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-29 Limit Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-29 Application Options Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-30 3-10 Freq (Frequency) Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-31 Freq (Frequency) Menu (Continued) . . . . . . . . . . . . . . . . . . . . . . . . . . 3-32 3-11 Frequency Menu with Offset Function . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-33 Freq 2/2 Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-34 Span Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-36 3-12 Zero Span IF BW Menu (Option 89) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-37 3-13 Amplitude Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-38Units & Detection Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-39 3-14 BW (Bandwidth) Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-40 Spectrum Analyzer MG PN: 10580-00349 Rev. K Contents-5 Table of Contents (Continued) 3-15 Measurements Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-41 [Spectrum] Measure Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-42 Power and BW Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-43 Field Strength Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-44 OCC BW Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-45 Channel Power Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-46 ACPR Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-47 EMF Menu (Option 444) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-49 Masks and C/I Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-50 Emission Mask (In-Band) Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-51 C/I Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-52 C/I Signal Type Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-53 AM/FM Demod 1/2 Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-54 Demod Type Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-55 AM/FM Demod 2/2 Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-56 Generator Menu (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-57 IQ Waveform Capture Menu (Option 24) . . . . . . . . . . . . . . . . . . . . . 3-58 IQ Capture Triggering Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-59 IQ Capture Save Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-59 IQ Capture Frequency/Amplitude Menu . . . . . . . . . . . . . . . . . . . . . . 3-60 Coverage Mapping Menu (Option 431) . . . . . . . . . . . . . . . . . . . . . . . . 3-61 Spectrogram Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-62 Signal Strength Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-63 RSSI Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-64 Signal ID Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-65 Interference Mapping Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-66 Bearing Lines Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-67 Mapping Save/Recall Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-68 Direction Finding Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-69 Pan & Zoom Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-70 DF Sound Settings Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-70 3-16 Marker Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-71 Marker and Peak Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-72 Marker 2/2 Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-73 3-17 Sweep Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-74 Sweep Mode Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-75 Triggering Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-76 Trigger Source Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-77 Gate Setup Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-78 Contents-6 PN: 10580-00349 Rev. K Spectrum Analyzer MG Table of Contents (Continued) 3-18 Trace Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-79 Trace A Ops Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-80 Trace B Ops Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-81 Trace C Ops Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-82 3-19 Limit Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-83 [Limit] Edit Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-84 [Limit] Edit Menu (Continued) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-85 Limit Move Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-86 Limit Envelope Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-87 Limit Advanced Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-89 3-20 Application Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-90 3-21 Other Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-90 Chapter 4—Channel Scanner (Option 27) 4-1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 4-2 General Measurement Setups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 4-3 Sample Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2 4-4 Custom Setup Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3 4-5 Custom Setup Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3 4-6 Script Master Measurement Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4 4-7 Channel Scanner Menu Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6 4-8 Scanner Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7 Channel Scan Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7 Freq Scan Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8 Scan Script Master Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9 4-9 Amplitude Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10 4-10 Custom Scan Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11 4-11 Measurements Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12 4-12 Sweep Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14 4-13 Measure Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14 4-14 Trace Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14 4-15 Limit Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14 4-16 Other Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14 Chapter 5—CW Signal Generator (Option 28) 5-1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1 Required Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1 5-2Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2 Spectrum Analyzer MG PN: 10580-00349 Rev. K Contents-7 Table of Contents (Continued) Chapter 6—Coverage Mapping (Option 431) 6-1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1 6-2 General Measurement Setups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1 6-3 Spectrum Analysis Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1 6-4 Coverage Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2 Anritsu easyMap Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4 Instrument Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5 Map the Signal Strength . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7 Save the Coverage Mapping Information . . . . . . . . . . . . . . . . . . . . . . . 6-9 6-5 Coverage Mapping Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-13 6-6 Coverage Mapping Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-15 Mapping Save/Recall Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-16 Pan & Zoom Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-17 Measurement Setup Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-19 Point Distance/Time Setup Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-20 RSSI Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-21 ACPR Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-22 Field Strength Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-23 Chapter 7—AM/FM/PM Analyzer (Option 509) 7-1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1 7-2 General Measurement Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2 7-3 Example FM Demodulation Measurement . . . . . . . . . . . . . . . . . . . . . . . . 7-4 7-4 AM/FM/PM Analyzer Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8 Map of Main Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-8 Map of Frequency Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-9 Map of Measurements Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-10 Map of Audio Demod Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-11 7-5 RF Freq (Frequency) Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-12 7-6 RF Span Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-13 7-7 (Signal) Standard List Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-14 7-8 Amplitude Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-15 7-9 Setup Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-16 7-10 Measurements Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-17 7-11 RF Spectrum Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-18 7-12 Audio Spectrum AM Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-19 7-13 Audio Waveform AM Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-20 7-14 Audio Spectrum FM Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-21 Contents-8 PN: 10580-00349 Rev. K Spectrum Analyzer MG Table of Contents (Continued) 7-15 Audio Waveform FM Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-22 7-16 Audio Spectrum PM Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-23 7-17 Audio Waveform PM Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-24 7-18 Coverage Mapping Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-25 Mapping Save/Recall Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-26 Measurement Setup Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-27 Point Distance/Time Setup Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-28 7-19 Audio Demod AM Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-29 7-20 Audio Demod FM Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-30 7-21 Marker Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-31 Chapter 8—Bias Tee (Option 10) 8-1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1 8-2 Bias Tee Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-3 Chapter 9—EMF (Option 444) 9-1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1 9-2 Connecting the Antenna . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1 9-3 EMF Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-2 EMF Auto Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-3 Trace Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-4 9-4 Measurement Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-5 Pass/Fail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-6 Index Spectrum Analyzer MG PN: 10580-00349 Rev. K 1-1 Chapter 1 — General Information 1-1 Introduction This Measurement Guide describes the test and measurement functions of Anritsu RF and Microwave Handheld Instruments. Basic spectrum analyzer functions are included with most Anritsu handheld instruments. Other functions are available only when the related option is installed and activated: • “Interference Analyzer (Option 25)” • “Channel Scanner (Option 27)” • “CW Signal Generator (Option 28)” • “Coverage Mapping (Option 431)” • “AM/FM/PM Analyzer (Option 509)” • “EMF (Option 444)” Screen captured images contained in this document are provided as examples. Illustrations of menu maps, or menu trees, may show submenu keys that display only under certain conditions. The actual displays, screen menus, and measurement details may differ based on instrument model, firmware version, installed options, and current instrument settings. 1-2 Selecting a Measurement Mode To switch to another measurement mode, or application: 1. Press the Shift front panel key, followed by Mode (9). The Mode Selector dialog opens. 2. Use the arrow keys or rotary knob, or press the touch screen to highlight the desired measurement mode. The list of available applications depends on the options that are installed and activated on your instrument. See Figure 1-1. 3. Press Enter. Figure 1-1. Mode Selector Dialog Box 1-3 Contacting Anritsu General Information 1-2 PN: 10580-00349 Rev. K Spectrum Analyzer MG On instruments that have a front panel Menu key, an alternate method of changing the measurement mode is to press Menu, then press the appropriate application icon on the touch screen. 1-3 Contacting Anritsu To contact Anritsu, pleasevisit: http://www.anritsu.com/contact-us On this page you can find links to sales, service, and support contact information for your country or region. You can also provide online feedback, complete a “Talk to Anritsu” form to have your questions answered, or obtain other services offered by Anritsu. Updated product information can be found on the Anritsu website: http://www.anritsu.com/ Search for the product model number. The latest documentation is on the product page under the Library tab. Figure 1-2. Menu Key Screen - Application Icons and User-Defined Shortcuts Spectrum Analyzer MG PN: 10580-00349 Rev. K 2-1 Chapter 2 — Spectrum Analyzer 2-1 Introduction Spectrum analyzer measurements include the use of additional functions beyond frequency, span, amplitude, and marker functions. Section 2-2 and Section 2-3 explain setup procedures and settings for making spectrum analyzer measurements. Section 2-4 through Section 2-8 focus on resolution bandwidth, video bandwidth, sweep, attenuator, and detection functions. Section 2-11 through Section 2-24 cover field measurements including brief examples demonstrating field strength, occupied bandwidth, channel power, adjacent channel power ratio, EMF, out-of-band spurious emissions, in-band/out-of-channel, AM/FM/SSB demodulation, masks and carrier to interference ratio (C/I), coverage mapping, and IQ waveform capture. Finally, Section 2-25 though Section 2-38 detail the submenus available in Spectrum Analyzer mode. 2-2 General Measurement Setups Refer to your instrument User Guide for instructions on setting up frequency, span, amplitude, GPS, limit lines, markers, and file management. 2-3 Making Spectrum Analyzer Measurements Required Equipment • Optionally, an antenna that is appropriate for the frequency range to be measured Required Setup • Place the instrument in Spectrum Analyzer mode. Refer to “Selecting a Measurement Mode” on page 1-1. • Connect the input signal or antenna to the RF In test port. Setting Frequency The tuning frequency range can be entered in several different ways depending upon what makes the most sense, either for the user or for the application. The center frequency and span can be specified, the start and stop frequencies can be entered, or a signal standard and channel number can be selected from the built-in list. Offset Frequency In addition, a user-defined frequency offset can be entered to adjust the frequency that is displayed on the instrument from the actual swept frequency. For example, if the DUT is an antenna system receiving signals in the 10 GHz range and offsetting the signals to the 1 GHz range, you can set a frequency offset in the spectrum analyzer in order to display the actual received antenna frequency in the sweep window. For a measurement example, see Figure 2-40 on page 2-55. 2-3 Making Spectrum Analyzer Measurements Spectrum Analyzer 2-2 PN: 10580-00349 Rev. K Spectrum Analyzer MG Both positive and negative offset values are allowed. Negative offsets can be useful for seeing differences from expected values. Enter a negative offset of the expected value, and the received antenna frequency should display in the 0 Hz range. When enabled, Offset is displayed at the bottom of the screen (Figure 2-40), and the Center Freq, Start Freq, and Stop Freq submenu keys indicate that a frequency offset has been turned on by adding the word Offset before Center, Start, and Stop. For menu examples, see Figure 2-36 on page 2-50 and Figure 2-38 on page 2-53. To remove a frequency offset, set the Freq Offset to 0 Hz. Setting Bandwidth Parameters Both resolution bandwidth (RBW) and video bandwidth (VBW) can be coupled to the frequency span automatically or manually set. When set to Auto RBW, RBW adjusts automatically in proportion to the frequency span. The default ratio of the span width to the resolution bandwidth is 100:1, and can be changed as follows: 1. Press the BW main menu key. 2. Press the Span/RBW submenu key. The current Span/RBW ratio is shown as part of the submenu key label. Change the value using the keypad, the directional arrows, or the rotary knob and then press Enter. When auto-coupling between the span and RBW is selected (the Auto RBW submenu key is toggled to “On”), this is indicated on the left side of the display with the RBW label and underneath it one to three digits followed by the frequency units; this represents the resolution bandwidth value. If manual RBW is selected (the Auto RBW submenu key is toggled “Off”), the label and value turn red and a ‘#’ symbol is shown in front of the RBW label. Adjust resolution bandwidth independently of the span. If an unavailable resolution bandwidth is entered, then the instrument selects the next higher resolution bandwidth. If a value greater than the widest RBW is entered, then the widest RBW will be selected. VBW can be set two ways – manually or by auto coupling. Auto coupling of the VBW links the video bandwidth to the resolution bandwidth, so that VBW varies in proportion to RBW. Auto coupling is indicated on the left side of the display with the VBW label and underneath it one to three digits and the frequency units; this represents the video bandwidth value. If manual VBW coupling is selected, the label and value turn red and the “#” symbol is shown in front of VBW on the left side of the display. Adjust video bandwidth independently of the RBW. If a non-existent video bandwidth is entered, then the instrument will select the next higher video bandwidth. If a value greater than the widest VBW is entered, then the widest VBW will be selected. The ratio of the resolution bandwidth to the video bandwidth can be changed by pressing the BW main menu key, the RBW/VBW submenu key, and then using the keypad, the directional arrows, or the rotary knob to set the ratio. By default, the RBW/VBW ratio is set to 3. The current value of the ratio is shown as part of the submenu key label. 1. Press the BW main menu key. 2. Press the RBW/VBW submenu key. The current RBW/VBW ratio is shown as part of the submenu key label. Enter the desired value. The RBW range varies with instrument features. Refer to the RBW submenu key description in “BW (Bandwidth) Menu” on page 2-60, and check your Technical Data Sheet for the RBW range of your instrument. Spectrum Analyzer 2-3 Making Spectrum Analyzer Measurements Spectrum Analyzer MG PN: 10580-00349 Rev. K 2-3 Setting Sweep Parameters To set the sweep parameters, press the Shift key followed by the Sweep (3) key. Single/Continuous When this submenu key is pressed, the instrument toggles between single sweep and continuous sweep. In single sweep mode, the instrument waits until the Sweep Once submenu key is pressed or another triggering mode is selected. Sweep Mode Several sweep modes are available on the instrument. Press the Sweep Mode submenu keys to select between Fast (default), Performance, No FFT, or Burst Detect. Note that Burst Detect is supported on MS2720T and MT8220T instrument models only. Improperly installed cellular boosters can sometimes produce burst interference. By using Burst Detect mode when available, a narrow pulsed or burst signal is easily seen in spectrum analyzer mode, capturing emitters as narrow as 200 μs. Burst Detect works in a maximum span of 15 MHz. Figure 2-1 shows two traces. The yellow trace is the live trace with Burst Detect sweep mode, while the green trace is a max hold trace. There is not much difference between the two traces, thus, max hold is no longer needed in order to see narrow pulsed signals. Figure 2-1. Example of Burst Detect Sweep Mode 2-3 Making Spectrum Analyzer Measurements Spectrum Analyzer 2-4 PN: 10580-00349 Rev. K Spectrum Analyzer MG The Show Help submenu key displays a table detailing thetrade-off between sweep speed and performance of the sweep mode options.. Trigger Type To select a specific type of triggering in zero span, press the Triggering submenu key followed by the Source submenu key. Selections are: Free Run: The default trigger type is “Free Run” in which the instrument begins another sweep as soon as one is finished. External: A TTL signal applied to the External Trigger BNC input connector causes a single sweep to occur. This mode is used in zero span, and triggering occurs on the rising edge of the signal. After the sweep is complete, the resultant trace is displayed until the next trigger signal arrives. Video: This mode is used in zero span to set the power level at which a sweep is initiated. The power level can be set from –130 dBm to +30 dBm. Trigger is based on the measured signal level. The sweep triggers when the signal level crosses the trigger level with a positive slope. If no signal crosses the trigger level, the last trace on the screen, before video triggering was selected, will be displayed. To change the video triggering level use the rotary knob, enter the desired amplitude with the keypad, or use the left or right arrows to change the setting by 1 dB or the up or down arrows to change the setting by 10 dB. IF Power (available on MS2720T model only): This mode is used in zero span to set IF power level as the trigger source. The power level can be set from –130 dBm to +30 dBm, using the rotary knob, arrow keys, or keypad. The trigger is based on the measured signal level. If no signal reaches or exceeds the trigger level, then no trace will be displayed on the screen. Zero Span IF Output (Standard or Option 89): Zero Span IF Output provides an IF signal that is nominally at 140 MHz out of a BNC female connector labeled IF Out 140 MHz or IF Out (option) 140 MHz. You can select Normal or any one of four fixed IF bandwidths of 7 MHz, 10 MHz, 16 MHz, or 32 MHz. In Normal, the bandwidth is set by the spectrum analyzer RBW selection (BW > Zero Span RBW). When Normal is selected, the IF bandwidth is influenced by the selection of RBW filters, although the digital RBW filters themselves are not employed. Note Sweep Mode menu functionality varies based on instrument model. Fast is the default sweep mode for instruments that have received the new instrument calibration from Anritsu. Notes The IF output signal is present only when the spectrum analyzer Span is set to zero and the Zero Span button has been pressed a second time to bring up the IF bandwidth menu (refer to “Zero Span IF BW Menu (Option 89)” on page 2-59). The key sequence is: Span > Zero Span > Zero Span. MS2723B and MS2724B instruments use IF frequency of 37.8 MHz rather than the 140 MHz of other Anritsu Spectrum Masters. IF output bandwidth is limited to 16 MHz. For these MS2723B and MS2724B instruments, the BNC connector is labeled IF Out 37.8 MHz. Spectrum Analyzer 2-3 Making Spectrum Analyzer Measurements Spectrum Analyzer MG PN: 10580-00349 Rev. K 2-5 Zero Span IF output effectively uses the spectrum analyzer as a receiver front-end, converting the input signal at the spectrum analyzer RF In connector to a signal centered at 140 MHz out of the IF Out 140 MHz connector. You can then process the IF signal in a way that meets your needs. That may mean using an A-to-D converter or some other signal processing method. An anti-aliasing filter can be employed in the signal processing to reduce the effect of noise and spurious signals. A filter centered on 140 MHz with a bandwidth slightly wider than 32 MHz is also advised to eliminate any undesired out-of-band signals on the IF output. In particular, signals at 100 MHz and its harmonics (that would be eliminated by the filter) are on the IF output. When IF output is turned on by setting the instrument to zero span , then pressing the Zero Span submenu key a second time displays the Zero Span IF Bandwidth menu (Figure 2-2). The selectable bandwidth values may differ among instrument types. This figure is typical. The Normal IF BW choice selects a bandwidth that uses analog bandpass filters in the normal RBW chain. By changing the RBW, different filter bandwidths are selected. The spectrum analyzer has several mixer bands. Depending on the operating frequency, the local oscillator may be above or below the input frequency. When the local oscillator frequency is below the input frequency, an increase in the input frequency results in an increase in the IF output frequency. When the local oscillator is above the input frequency, an increase in the input frequency moves it closer to the local oscillator frequency and the IF output frequency consequently decreases. The following tables show the bands and indicates where the LO frequency is, in relation to the RF frequency. Figure 2-2. Zero Span IF Bandwidth Selection Menu Zero Span IF BW Back 7 MHz BW 10 MHz BW 16 MHz BW 32 MHz BW Normal 2-3 Making Spectrum Analyzer Measurements Spectrum Analyzer 2-6 PN: 10580-00349 Rev. K Spectrum Analyzer MG “Inverted” means that the IF is spectrally inverted from the input (as the input frequency goes higher, the IF goes lower). “Not Inverted” means that the IF is not spectrally inverted (as the input frequency goes higher, the IF goes higher). You need to take frequency inversion into account when processing the IF signal. Assuming that the IF has been processed to yield I and Q data, inversion is easily done by swapping I and Q. A residual frequency offset of the IF may exist compared to the RF due to the resolution of the first and second local oscillators, as well as the calibration of the IF filters. This offset is usually on the order of several kHz, but may be up to 10 kHz or so if the narrowest IF filters are selected. To determine the residual offset, you need a second spectrum analyzer or a frequency counter. 1. Attach a signal source (or antenna) to the spectrum analyzer and set the center frequency to the center of the signal being received. 2. Press BW then Zero Span, and then press Zero Span a second time to turn on the IF output. 3. Attach a second spectrum analyzer to the IF output and set the center frequency to 140 MHz. Set the span of the second spectrum analyzer to 100 kHz or less to have the resolution needed to be able to measure an offset that may be 25 kHz or less. 4. Measure the frequency of the IF signal to see how far the signal is offset from 140 MHz. Table 2-1. Mixer Bands and LO Relation to RF Frequency (Spectrum Master) Band Low RF MHz High RF MHz Local Oscillator Side Output Spectrum 0 0 2650 High Inverted 1 2650 5350 High Inverted 2 5350 9200 High Inverted 3 9200 13000 Low Not Inverted 4 13000 16500 High Inverted 5 16500 20000 Low Not Inverted 6 20000 32800 High Inverted 7 32800 43000 Low Not Inverted Table 2-2. Mixer Bands and LO Relation to RF Frequency (BTS Master) Band Low RF MHz High RF MHz Local Oscillator Side Output Spectrum 1 0 2800 High Inverted 2 2800 3300 High Inverted 3 3300 4000 High Inverted 4 4000 4700 High Inverted 5 4700 5500 Low Not Inverted 6 5500 6300 Low Not Inverted 7 6300 7100 Low Not Inverted Spectrum Analyzer 2-3 Making Spectrum Analyzer Measurements Spectrum Analyzer MG PN: 10580-00349 Rev. K 2-7 Gated Sweep (Option 90) To set up the instrument for gated sweep measurements, press the Gated Sweep Setup key under the Sweep menu. The instrument screen changes to a dual graph view that makes it easier to set up the Gate Length and Gate Delay using the time domain/zero span view in the bottom graph while simultaneously viewing the signal spectrum in the top graph. The Gate Length is represented by the width of the displayed blue dashed rectangle. See Figure 2-3. This is useful for measuring signals in the time domain such as pulsedRF, time multiplexed, or burst modulated signals. The Gate Source selected determines the trigger source from which the gate is controlled. Not all instrument models and options support all triggering selections. (Refer to “Gate Setup Menu” on page 2-68.) Gate Polarity controls the triggering edge of the selected triggering source. The Gate View Settings key brings up a submenu where you can independently set the Zero Span RBW, Zero Span VBW, and Zero Span Time. Zero Span Time controls the time scale of the Gate View graph. Once the gate has been set up, you can apply gating to the spectrum by setting Gated Sweep to On. Gating will continue to be applied when you press Back and access other measurements and functions of the spectrum analyzer until either: (1) Gated Sweep is explicitly set to Off or (2) the Span setting is changed to Zero Span. Gated Sweep is not allowed in Zero Span mode. Figure 2-3. Gated Sweep Example - External Gate Source 2-4 Resolution Bandwidth Spectrum Analyzer 2-8 PN: 10580-00349 Rev. K Spectrum Analyzer MG 2-4 Resolution Bandwidth Resolution Bandwidth (RBW) determines frequency selectivity. The spectrum analyzer traces the shape of the RBW filter as it tunes past a signal. The choice of resolution bandwidth depends on several factors. Filters take time to settle. The output of the filter will take some time to settle to the correct value, so that it can be measured. The narrower the filter bandwidth (resolution bandwidth), the longer the settling time needs to be, and therefore, the slower the sweep speed. The choice of resolution bandwidth will depend upon the signal being measured. If two closely-spaced signals are to be measured individually, then a narrow bandwidth is required. If a wider bandwidth is used, then the energy of both signals will be included in the measurement. Thus, the wider bandwidth does not have the ability to look at frequencies selectively, but instead simultaneously measures all signals falling within the resolution bandwidth. Therefore, a broadband measurement would include all signals and noise within the measurement bandwidth into a single measurement. On the other hand, a narrow-band measurement will separate the frequency components, resulting in a measurement that includes separate peaks for each signal. There are advantages to each. The ultimate decision will depend upon the type of measurement required. There is always some amount of noise present in a measurement. Noise is often broadband in nature; that is, it exists at a broad range of frequencies. If the noise is included in the measurement, the measured value could be in error (too large) depending upon the noise level. With a wide bandwidth, more noise is included in the measurement. With a narrow bandwidth, less noise enters the resolution bandwidth filter, and the measurement is more accurate. If the resolution bandwidth is narrower, the noise floor will drop on the spectrum analyzer display. As the measured noise level drops, smaller signals that were previously obscured by the noise can now be measured. 2-5 Video Bandwidth Spectrum analyzers typically use another type of filtering after the detector called video filtering. This filter also affects the noise on the display but in a different manner than the resolution bandwidth. In video filtering, the average level of the noise remains the same, but the variation in the noise is reduced. Hence, the effect of video filtering is a “smoothing” of the signal noise. The resultant effect on the analyzer’s display is that the noise floor compresses into a thinner trace, while the average position of the trace remains the same. Changing the video bandwidth (VBW) does not improve sensitivity, but it does improve discernability and repeatability when making low-level measurements. As a general rule, most field spectrum analyzer measurements are made at a video bandwidth that is a factor of 10 to 100 less than the resolution bandwidth. This ratio can be specified in the BW main menu. Using this ratio, with a resolution bandwidth of 30 kHz, typically, the video bandwidth is set between 300 Hz and 3 kHz, although it can be set anywhere from 1 Hz to 10 MHz. Spectrum Analyzer 2-6 Sweep Limitations Spectrum Analyzer MG PN: 10580-00349 Rev. K 2-9 2-6 Sweep Limitations With some spectrum analyzers, the user has control over sweep time (the elapsed time of each sweep, sometimes called scan time). An analyzer cannot be swept arbitrarily fast while maintaining its specified accuracy, but will have a sweep rate limitation depending upon the resolution bandwidth, video bandwidth, and frequency range selected. The sweep rate is not usually chosen by the user but is determined by the frequency range swept divided by the sweep time. The limitation on sweep rate comes from the settling or response time of the resolution and video bandwidth filters. If an analyzer is swept too quickly, the filters do not have time to respond, and the measurement is inaccurate. Under such conditions, the analyzer display tends to have a “smeared” look to it, with the spectral lines being wider than normal and shifted to the right and at a lower amplitude than is correct. Anritsu products are designed to relieve the user from having to calculate the sweep speed or experiment to discover a sweep speed that yields accurate results. When changing the RBW and VBW, the sweep speed automatically changes to the fastest sweep speed that will yield accurate results. The sweep speed will be faster for a wide RBW or VBW and slower for a narrow RBW or VBW. The sweep speed can also be changed manually, by pressing the Sweep key and selecting the Sweep Time submenu key. Enter a sweep time from 10 μs to 600 seconds. If the minimum sweep time entered by the user is less than the value needed to assure accurate results, the value that delivers accurate results will be used. Regardless of the minimum sweep time setting, the instrument will never sweep faster than the RBW and VBW settings will allow. The instrument is designed to ensure that no uncalibrated measurement conditions will occur. 2-7 Attenuator Functions The Spectrum Analyzer includes a step attenuator at the RF input. This attenuator is used to reduce large signals to levels that make best use of the analyzer’s dynamic range. Normally, the input attenuation automatically adjusts as a function of Reference Level. In the Amplitude menu, the Attn Lvl key allows manual adjustment of the input attenuation, using the numeric keypad, the Up/Down arrow keys, or the rotary knob. In Auto Atten mode, as the reference level is increased, the attenuation is increased. Note The following actions, listed in decreasing order of effectiveness, can facilitate the detection of low-level CW signals: 1. Decrease the reference level and attenuation. Refer to “Amplitude Menu” on page 2-56. 2. Turn on the Preamp. 3. Reduce RBW. Refer to “BW (Bandwidth) Menu” on page 2-60. 4. Decrease VBW (RBW/VBW = 10 is often optimal for this purpose). 5. Use trace averaging if VBW is already set to 1 Hz. 2-8 Detection Spectrum Analyzer 2-10 PN: 10580-00349 Rev. K Spectrum Analyzer MG 2-8 Detection Several detection methods tailor the performance of the instrument to meet specific measurement requirements. In general, several measurement points are calculated for each display point. The various detection methods are different ways of dealing with how measurement point data is shown at each display point. Refer to “Units & Detection Menu” on page 2-57. Peak: This method causes the largest measurement point to be shown for each display point, and ensures that a narrow peak is not missed. RMS/Avg: This method performs a root-mean-square calculation of all the measurement points in each display point. This is particularly usefulin displaying the average value of noise or noise-like signals. Negative: This method causes the smallest measurement point to be shown for each display point. It is especially useful in zero span, to see if the signal amplitude drops briefly. The method is also useful when looking at modulated signals, to see if some frequencies are not being used. Sample: This is the fastest detection method because for each display point, only one frequency point is measured. Use this method when speed is of paramount importance and the possibility of missing a narrow peak is not important. Quasi-peak: When this selection is made, resolution bandwidths and video bandwidths of 200 Hz, 9 kHz and 120 kHz are available. This detection method is designed to meet CISPR requirements. (Not available in zero span.) 2-9 Indications of Excessive Signal Level The Spectrum Analyzer has built-in features to indicate when a received signal is too high for the current setup. Figure 2-4 through Figure 2-8 illustrate a normal trace followed by examples of screen messages indicating excessive signal levels. Before proceeding with the measurements, adjust the reference level and/or the attenuator level as instructed. Adjusting the resolution bandwidth and frequency range may also help. Spectrum Analyzer 2-9 Indications of Excessive Signal Level Spectrum Analyzer MG PN: 10580-00349 Rev. K 2-11 Figure 2-4. Normal Trace Figure 2-5. Saturation - Off Screen 2-9 Indications of Excessive Signal Level Spectrum Analyzer 2-12 PN: 10580-00349 Rev. K Spectrum Analyzer MG Figure 2-6. ADC Over Range - On Screen Figure 2-7. Saturation and ADC Overload Spectrum Analyzer 2-9 Indications of Excessive Signal Level Spectrum Analyzer MG PN: 10580-00349 Rev. K 2-13 Figure 2-8. Over Power Error (MT8220T and MS2720T-0709 only) 2-10 Preamplifier Measurement Example Spectrum Analyzer 2-14 PN: 10580-00349 Rev. K Spectrum Analyzer MG 2-10 Preamplifier Measurement Example The preamplifier can be turned on and off by pressing the Amplitude main menu key, then selecting the Preamp On/Off submenu key. Figure 2-9 shows the noise floor with the preamplifier off (green trace) and on (yellow trace). Notice that when the preamplifier is turned on, the noise floor drops significantly. 2-11 Field Measurements In Spectrum Analyzer mode, smart one-button measurements are built-in for field strength, occupied bandwidth, channel power, adjacent channel power ratio, emission mask, and carrier to interference ratio (C/I) tests. In addition, AM/FM/SSB demodulation is available to aid in the identification of interfering signals. The following sections present brief examples demonstrating the use of these measurements. Figure 2-9. Preamplifier On and Off Spectrum Analyzer 2-12 Field Strength Spectrum Analyzer MG PN: 10580-00349 Rev. K 2-15 2-12 Field Strength Required Equipment Portable Antenna for which antenna factors or antenna gain and bandwidth data are available. Procedure 1. Press the Shift key then the Measure (4) key. Then press the Power and Bandwidth submenu key, and press the Field Strength submenu key followed by pressing the On/Off submenu key so that On is underlined. 2. Press the Antenna submenu key to display the loaded antenna profiles with their model number and frequency range. Use the up or down arrow keys or the rotary knob to select the desired antenna. Press the Enter key to select or ESC to cancel. When the Field Strength measurement is enabled, an additional plot is shown at the bottom of the display indicating the selected antenna factor over the currently set frequency span. The field strength measurement is automatically compensated for this antenna factor. 3. Connect the antenna to the RF In port. Note Select an antenna from the standard list available or use the Antenna Editor feature of Anritsu Master Software Tools to define a custom antenna and upload the antenna information to the antenna list. Figure 2-10. Field Strength Measurement Display 2-12 Field Strength Spectrum Analyzer 2-16 PN: 10580-00349 Rev. K Spectrum Analyzer MG 4. Press the Freq main menu key, press the Center Freq submenu key, and enter the center frequency. 5. Press the Span main menu key. Set the span wide enough to include the primary channel bandwidth and upper and lower channel bandwidths. At least a portion of the span has to include a frequency within the antenna’s specified range. 6. Press the BW main menu key and verify that Auto RBW and Auto VBW are On. 7. To change the units of measurement, press the Amplitude main menu key, then press the Units submenu key and press dBm/m2, dBV/m, dBmV/m, dBµV/m, Volt/m, Watt/m2, dBW/m2, A/m, dBA/m, or Watt/cm2. The instrument automatically adjusts the measurement by the antenna factors selected. Marker values will be displayed in the same units as selected for amplitude. Antenna Calculations The following is a list of various antenna calculations should you find it necessary to convert from one parameter to another: Conversion of signal levels from watts to volts in a 50 ohm system: P = V2/R where: P = power in Watts V = voltage level in Volts R = resistance in ohms Note that 1mW = 10–3 W and 1µV = 10–6 V. For power in dBm, and voltage in dB (µV): VdB(µV) = P(dBm) + 107 dB Power density to field strength: An alternate measure of field strength is power density: Pd = E 2 / 120π where: E = field strength in V/m Pd = Power density in W/m 2 Power density at a point: Pd = PtGt / (4πr 2) where: Pd = power density in W/m Pt = power transmitted in Watts Gt = gain of transmitting antenna r = distance from the antenna in meters This equation is only valid in the far field, where electric and magnetic fields are related by the characteristic impedance of free space. Spectrum Analyzer 2-13 Occupied Bandwidth Measurement Spectrum Analyzer MG PN: 10580-00349 Rev. K 2-17 2-13 Occupied Bandwidth Measurement Occupied Bandwidth (OBW) is a common measurement performed on radio transmitters. This measurement calculates the bandwidth containing the total integrated power occupied in a given signal bandwidth. There are two different methods of calculation depending upon the technique used to modulate the carrier. • % Integrated Power Method: The occupied frequency bandwidth is calculated as the bandwidth containing the specified percentage of the transmitted power. • > dBc Method: The occupied frequency bandwidth is defined as the bandwidth between the upper and lower frequency points at which the signal level is a desired number of dB below the peak carrier level. Required Equipment • Test Port Extension Cable, Anritsu part number 15NNF50-1.5C • 30 dB, 50 Watt, bi-directional, DC –18 GHz, N(m) – N(f), Attenuator, Anritsu 42N50A-30 (required if the power level being measured is > +30 dBm) Procedure 1. Using the test port extension cable and the 30 dB, 50 watt, bi-directional attenuator (if needed) connect the RF In port to the appropriate transmitter test port or signal source. 2. Press the Freq main menu key followed by the Center Freq submenu key and enter the center frequency using the keypad, the arrow keys, or the rotary knob. If entering a frequency using the keypad, the submenu key labels change to GHz, MHz, kHz, and Hz. Press the appropriate units key. Pressing the Enter key has the same effect as the MHz submenu key. 3. If an attenuator was connected in Step 1, then press the Amplitude main menu key then press the RL Offset submenu key, enter 30 then select dB External Loss to compensate for the loss in the attenuator. 4. Press the Amplitude main menu key then press the Reference Level submenu key to set the appropriate reference level. 5. Press the Atten Lvl submenukey to set the input attenuation level or leave Auto Atten set to On. 6. Press the BW main menu key to set the resolution bandwidth and video bandwidth if desired. 7. Press the Shift key then the Measure (4) key. Then press the Power and Bandwidth submenu key, and press the OCC BW submenu key. Choose the measurement method (% Int Pwr or > dBc) by pressing the Method submenu key. The selected method is underlined. 8. Press the dBc or % submenu keys to adjust the settings as needed. Common values are 99% and 30 dBc. 9. Press the On/Off submenu key to start the measurement. An information box will appear below the graph while occupied bandwidth measurement is on. 2-13 Occupied Bandwidth Measurement Spectrum Analyzer 2-18 PN: 10580-00349 Rev. K Spectrum Analyzer MG Figure 2-11 shows the occupied bandwidth results using the percent of power method on a WCDMA signal. Occupied Bandwidth is a constant measurement; after it is turned on, it remains on until it is turned off by pressing the On/Off submenu key again. Occupied bandwidth is calculated at the end of each sweep. Figure 2-11. Occupied Bandwidth Results Using the % of Power Method Spectrum Analyzer 2-14 Channel Power Measurement Spectrum Analyzer MG PN: 10580-00349 Rev. K 2-19 2-14 Channel Power Measurement Channel power measurement is one of most common measurements for a radio transmitter. This test measures the output power, or channel power, of a transmitter over the frequency range. Out-of-specification power measurements indicate system faults, which can be in the power amplifiers or in filter circuits. Channel Power measurements can be used to validate transmitter performance, comply with government regulations, or to keep overall system interference at a minimum. Frequency and span settings for many signal standards can be set. 1. Press the Freq main menu key. 2. Press the Signal Standard submenu key. Choose the desired standard and press Enter. 3. Press the Channel # submenu key to enter the channel number at which the measurement is to take place and press Enter. 4. Press the Shift key then the Measure (4) key. Then press the Power and Bandwidth submenu key, and press the Channel Power submenu key. 5. Press the On/Off submenu key to start and stop channel power measurements. Channel Power Measurement for GSM Global Systems for Mobile (GSM) communication is a globally accepted standard for digital cellular communication. A number of frequency bands that are allocated to GSM mobile phones use a combination of Frequency Division Multiple Access (FDMA) and Time Division Multiple Access (TDMA). Within each band, are approximately one hundred available carrier frequencies on 200 kHz spacing (FDMA), and each carrier is broken up into time-slots so as to support eight separate conversations (TDMA). GSM uses the Gaussian Minimum Shift Keying (GMSK) modulation method. Required Equipment • Test Port extension cable, Anritsu 15NNF50-1.5C Procedure 1. Using the test port extension cable, connect the signal source to the RF In test port. 2. Press the Amplitude main menu key and press the Reference Level submenu key to set the reference level to –20 dBm. Adjust the values given in this procedure to match your measurement conditions. 3. Press the Scale submenu key and set the scale to 10 dB/div. 4. Press the BW main menu key and verify that Auto RBW and Auto VBW are On. 5. Press the Freq main menu key followed by the Signal Standard submenu key. Scroll through the dialog box using the up or down arrow keys or the rotary knob to highlight the GSM 900 - Downlink standard for the measurement and press Enter. 6. Press the Channel# submenu key and enter the channel number using the keypad, the arrow keys, or the rotary knob. For this example, select Channel 60. 7. Press the Shift key then the Measure (4) key. Then press the Power and Bandwidth submenu key, and press the Channel Power submenu key. 8. Verify that the center frequency is set to that of the GSM signal, in this case 947.0 MHz by looking at the center frequency annotation on-screen. 2-14 Channel Power Measurement Spectrum Analyzer 2-20 PN: 10580-00349 Rev. K Spectrum Analyzer MG 9. Press the Ch Pwr Width submenu key and enter 200 kHz for the integration bandwidth, or set the integration bandwidth appropriate for the particular application. 10. Press the Span submenu key and enter 600 kHz as the channel span, or set the channel span to a value appropriate for the particular application. 11. Make the measurement by pressing the Measure (4) key, the Power and Bandwidth submenu key, and the Channel Power submenu key. Then press On. The measurement results are displayed in the message area. Note Channel Power is a constant measurement. After it is turned on, it will remain on until it is turned off by pressing the On/Off submenu key again. Spectrum Analyzer 2-15 Adjacent Channel Power Measurement Spectrum Analyzer MG PN: 10580-00349 Rev. K 2-21 2-15 Adjacent Channel Power Measurement Required Equipment • 30 dB, 50 watt, Bi-Directional, DC–18 GHz, N(m)–N(f) Attenuator, Anritsu Part Number 42N50A-30 (if required for the power level being measured) • Test Port extension cable, Anritsu Part Number 15NNF50-1.5C Procedure 1. Using the test port extension cable and 30 dB attenuator, connect the signal source to the input of the attenuator, and connect the output of the attenuator to the RF In test port. 2. If an attenuator was connected in step 1, press the Amplitude main menu key then press the RL Offset submenu key, enter 30 then select dB External Loss to compensate for the loss in the attenuator. 3. Press the Amplitude main menu key and press the Reference Level submenu key to set the reference level to 60 dBm. 4. Press the Atten Lvl submenu key to set the input attenuation level needed for the measurement. This value depends on the input power level and any external attenuator. Enter an attenuation level to achieve roughly –40 dBm at the input mixer. 5. Press the BW main menu key and verify that Auto RBW and Auto VBW are On. 6. There are two ways to set the measurement parameters. If the signal standard and channel are known, press the Freq main menu key and set the signal standard and press Channel submenu key for the signal to be measured, then skip to Step 12. If the signal standard and channel are not known, follow the procedure in Step 7 through Step 11. 7. Press the Freq main menu key, press the Center Freq submenu key, and enter the desired center frequency. 8. Press the Shift key then the Measure (4) key. Then press the Power and Bandwidth submenu key, and press the ACPR submenu key. 9. Press the Main Ch BW submenu key, and enter the main channel bandwidth. 10. Press the Adj Ch BW submenu key, and enter the adjacent channel bandwidth. 11. Press the Ch Spacing submenu key, and enter the channel spacing. 12. Make the measurement by pressing the On/Off submenu key. The detection method is automatically changed to RMS Average. Solid vertical lines are drawn on the display to indicate the main channel. Dashed vertical lines define the adjacent channels. The SPA will display the measurement results in the message area. Note Adjacent Channel Power Ratio is a constant measurement. After it is turned on, it will remain on until it is turned off by pressing the On/Off submenu key again. 2-16 EMF Measurement (Option 444) Spectrum Analyzer 2-22 PN: 10580-00349 Rev. K Spectrum Analyzer MG 2-16 EMF Measurement (Option 444) Required Equipment EMF measurements are available in the Spectrum Analyzer mode only when Option 444 is installed. The option requires an isotropic antenna, at a frequency range that is within specification of the instrument. Refer to the isotropic antennaand spectrum analyzer Technical Data Sheets. Procedure 1. Press the Shift key, then the Mode (9) key to open the Mode Selector dialog box. Use the Up or Down arrow keys to highlight the Spectrum Analyzer measurement mode and press Enter. 2. Press the Shift key followed by the Measure (4) key. 3. To access EMF Measurement, press the Power and Bandwidth submenu key, then EMF Measurement. Chapter 9, “EMF (Option 444)” provides connection instructions for the antenna and detailed descriptions of the EMF Measurement menu and submenus. Spectrum Analyzer 2-17 Out-of-Band Spurious Emission Measurements Spectrum Analyzer MG PN: 10580-00349 Rev. K 2-23 2-17 Out-of-Band Spurious Emission Measurements The measurements described in this section are distinct from the built-in out-of-band spurious emission measurements that are performed via the Masks and C/I submenu. See “Spurious Emissions (Out-of-Band)” on page 2-31. Required Equipment • Test Port extension cable, Anritsu 15NNF50-1.5C Procedure 1. Using the test port extension cable, connect the signal source to the RF In test port. 2. Press the Freq main menu key, press the Center Freq submenu key, and enter the center frequency. 3. Press the Span main menu key. Set the span wide enough to include the primary channel bandwidth and upper and lower channel bandwidths. 4. Press the Amplitude main menu key, then press the Reference Level submenu key and set the reference level to –20 dBm. 5. Press the Auto Atten submenu key and select On. 6. Press the BW main menu key, then use the RBW and VBW submenu keys to set the resolution bandwidth to 3 kHz and the video bandwidth to 300 Hz. 7. Press the Marker main menu key and press the Marker 123456 submenu key to select Marker 1. The underlined number indicates the active marker. 8. Press the On/Off submenu key to activate the marker. Use the arrow keys, the keypad or the rotary knob to move the marker over one of the spurs. To use the corresponding Figure 2-12. Select Active Marker with the Touch Screen 2-17 Out-of-Band Spurious Emission Measurements Spectrum Analyzer 2-24 PN: 10580-00349 Rev. K Spectrum Analyzer MG delta marker, press the Delta submenu key so that On is underlined. Use the arrow keys or rotary knob to move the delta marker to the desired frequency and press Enter. 9. Compare the value of the marker to the specified allowable level of out-of-band spurious emissions for the corresponding channel transmit frequency. 10. Repeat Step 8 and Step 9 for the remaining spurs. Use either Marker 1 again, or choose another marker. Figure 2-13 shows a simulated out-of-band spurious signal 3 MHz from the carrier using a delta marker. Figure 2-13. Out-of-Band Spurious Emission Measurement Spectrum Analyzer 2-18 In-Band/Out-of-Channel Measurements Spectrum Analyzer MG PN: 10580-00349 Rev. K 2-25 2-18 In-Band/Out-of-Channel Measurements The in-band/out-of-channel measurements are used to determine the distortion and interference within the system band, but outside of the transmitting channel. These measurements include in-band spurious emissions and adjacent channel power ratio (also called spectral regrowth). There are stringent regulatory controls on the amount of interference that a transmitter can spill to neighboring channels. To determine compliance with the allowable level of spurious emissions, two parameters need to be specified: • Measurement channel bandwidth • Allowable level of spurious emissions The measurements described in this section are distinct from the built-in emission mask (in-band) measurements that are performed via the Masks and C/I submenu. See “Emission Mask (In-Band)” on page 2-30. Required Equipment • 30 dB, 50 watt, Bi-Directional, DC–18 GHz, N(m)–N(f), Attenuator, Anritsu 42N50A-30 • Test Port extension cable, Anritsu 15NNF50-1.5C Procedure 1. Using the test port extension cable and 30 dB, 50 watt, (Bi-directional) attenuator, connect the RF In port to the appropriate transmit test port. 2. Press the Freq main menu key, press the Center Freq submenu key, and enter the center frequency. 3. Press the Span main menu key. Set the span wide enough to include the primary channel bandwidth and upper and lower channel bandwidths. 4. Press the Amplitude main menu key and then press the Reference Level submenu key to set the reference level to –20 dBm. 5. Press the RL Offset submenu key, enter 30 then select dB External Loss to compensate for the loss in the attenuator. 6. Press the Auto Atten submenu key and set the attenuation to On. 7. Press the BW main menu key and use the RBW and VBW submenu keys to set the resolution bandwidth to 10 kHz and the video bandwidth to 300 Hz. 8. Press the Marker main menu key and press the Marker 123456 submenu key to select Marker 1. The underlined number indicates the active marker. 9. Press the On/Off submenu key and use the arrow keys, the keypad or the rotary knob to move the marker over one of the spurs. 10. Compare the value of the marker to the specified allowable level of in-band/out-of-channel spurious emissions for the corresponding channel transmit frequency. 11. Repeat steps 9 and 10 for the remaining spurs. Use either Marker 1 again, or choose another marker. 2-19 AM/FM/SSB Demodulation Spectrum Analyzer 2-26 PN: 10580-00349 Rev. K Spectrum Analyzer MG 2-19 AM/FM/SSB Demodulation The built-in demodulator for AM, narrowband FM, wideband FM, and single sideband (selectable upper sideband (USB) and lower sideband (LSB) signals) allows a technician to hear an interfering signal. The demodulated signal can be heard using either the built-in speaker or a monaural headset connected to the 2.5 mm jack on the connector panel. Procedure 1. Press the Shift key followed by the Measure (4) key. Then press the AM/FM Demod submenu key. 2. Press the Demod Type submenu key and press FM Wide Band, FM Narrow Band, AM, USB, or LSB to match the modulation format of the signal. 3. Press the Back submenu key. 4. Press the Demod Freq submenu key and use the keypad or rotary knob to enter the center frequency of the signal to be demodulated. For USB and LSB signals, fine tune the signal by adjusting the Beat Freq Osc. By default the BFO frequency is set to zero, meaning that the re-injected carrier is exactly at the demodulation frequency. The Beat Freq Osc submenu key allows adjustment of the beat frequency oscillator to fine tune the signal through a span of ± 10000 Hz. 5. Press the On/Off submenu key to enable the demodulation. 6. Press the Volume submenu key and use the up or down arrow keys or the rotary knob to change the audio volume from 0% to 100%. For most headsets, a volume of 40% is adequate. 7. The Demod Time submenu key sets the time that the instrument will demodulate the signal. Enter a value from 100 ms to 500 seconds. Spectrum Analyzer 2-20 Carrier to Interference Ratio Measurement Spectrum Analyzer MG PN: 10580-00349 Rev. K 2-27 2-20 Carrier to Interference Ratio Measurement Carrier to Interference Ratio (C/I) Measurement is a two-step process, first measuring the carrier level and then, with the carrier turned off, measuring the remaining signals and noise in the band of interest. After the two measurements are complete, the ratio of the carrier level to the noise plus interference is displayed using three assumptions: • The interferer is a narrowband frequency hopping signal (NB FHSS) • The interferer is a wideband frequency hopping signal (WB FHSS) • The interferer is a broadband signal (BB). The primary application for this type of measurement is determining the magnitude of interference problems for 802.11b, 802.11g and 802.11a access points (hot spots). Procedure 1. Press the Freq main menu
Compartilhar