Prévia do material em texto
594 Chapter 22 An Introduction to Electroanalytical Chemistry QUESTIONS AND PROBLEMS *Answers are provided at the end of the book for problems marked with an asterisk. Problems with this icon are best solved using spreadsheets. * 22-1 Calculate the electrode potentials of the following half-cells. (a) Ag1 10.0436 M2 0Ag (b) Fe31 15.34 3 1024 M2,Fe21 10.090 M2 0Pt (c) AgBr1sat’d2,Br2 10.037 M2 0Ag * 22-2 Calculate the electrode potentials of the following half-cells. (a) HCl11.53 M2 0H210.929 atm2,Pt (b) IO32 10.154 M2,I212.00 3 1024 M2,H1 12.75 3 1023 M2 0Pt (c) Ag2CrO41sat’d2,CrO422 10.0625 M2 0Ag FIGURE 22-9 Summary of common electroanalytical methods. Quantity measured given in parentheses. (I or i 5 current, E 5 potential, R 5 resistance, G 5 conductance, Q 5 quantity of charge, t 5 time, vol 5 volume of a standard solution, m 5 mass of an electrodeposited species.) Electroanalytical methods Interfacial methods Bulk methods Static methods (I = 0) Dynamic methods (I > 0) Conductometry (G = 1/R) Conductometric titrations (volume) Potentiometry (E) Potentiometric titrations (vol) Controlled potential Constant current Electrogravimetry (m) Coulometric titrations (Q = It) Voltammetry [i = f(E)] Constant electrode potential coulometry (Q = ti dt) Amperometric titrations (vol) Electrogravimetry (m) 0 595 Questions and Problems * 22-3 For each of the following half-cells, compare electrode potentials calculated from (1) concentration and (2) activity data. (a) HCl10.0200 M2,NaCl10.0300 M2 0H211.00 atm2,Pt (b) Fe1ClO42210.0111 M2,Fe1ClO42310.0111 M2 0Pt 22-4 For each of the following half-cells, compare electrode potentials calculated from (1) concentration and (2) activity data. (a) Sn1ClO42213.00 3 1025 M2,Sn1ClO42416.00 3 1025 M2 0Pt (b) Sn1ClO42213.00 3 1025 M2,Sn1ClO42416.00 3 1025 M2,NaClO410.0800 M2 0Pt * 22-5 Calculate the potential of a silver electrode in contact with the following: (a) a solution that is 0.0255 M in I2 and saturated with AgI. (b) a solution that is 0.0035 M in CN2 and 0.0550 M in Ag1CN222. (c) the solution that results from mixing 25.0 mL of 0.0500 M KBr with 20.0 mL of 0.100 M Ag1. (d) the solution that results from mixing 25.0 mL of 0.0500 M Ag1 with 20.0 mL of 0.100 M KBr. * 22-6 Calculate the electrode potentials for the following systems: (a) Cr2O722 15.00 3 1023 M2,Cr31 12.50 3 1022 M2,H1 10.100 M2 0Pt (b) UO221 10.100 M2,U41 10.200 M2,H1 10.600 M2 0Pt * 22-7 Calculate the theoretical potential of each of the following cells. Is the cell reaction spontaneous as written or spontaneous in the opposite direction? (a) Pt 0Cr31 12.00 3 1024 M2,Cr21 11.50 3 1023 M2 iPb21 15.60 3 1022 M2 0Pb (b) Hg 0Hg221 12.00 3 1022 M2 iH1 11.50 3 1022 M2,V31 12.00 3 1022 M2,VO21 13.00 3 1023 M2 0Pt (c) Pt 0Fe31 13.00 3 1022 M2,Fe21 14.00 3 1025 M2 iSn21 13.50 3 1022 M2,Sn41 15.50 3 1024 M2 0Pt 22-8 Calculate the theoretical potential of each of the following cells. Is the cell reaction spontaneous as written or spontaneous in the opposite direction? (a) Bi 0BiO1 10.0300 M2,H1 10.100 M2 iI2 10.100 M2,AgI1sat’d2 0Ag (b) Zn 0Zn21 15.75 3 1024 M2 iFe1CN2642 15.50 3 1022 M2,Fe1CN2632 16.75 3 1022 M2 0Pt (c) Pt,H210.200 atm2 0HCl18.25 3 1024 M2, AgCl1sat’d2 0Ag * 22-9 Compute E0 for the process Ni1CN2422 1 2e2 m Ni1s2 1 4CN2 given that the formation constant for the complex is 1.0 3 1022. * 22-10 The solubility product constant for PbI2 is 7.1 3 1029 at 25°C. Calculate E0 for the process PbI21s2 1 2e2 m Pb1s2 1 2I2 * 22-11 Calculate the standard potential for the half-reaction BiOCl1s2 1 2H1 1 3e2 m Bi1s2 1 Cl2 1 H2O given that Ksp for BiOCl has a value of 8.1 3 10219. * 22-12 Calculate the standard potential for the half-reaction Al1C2O42 22 1 3e2 S Al 1s2 1 2C2O422 if the formation constant for the complex is 1.3 3 1013. 596 Chapter 22 An Introduction to Electroanalytical Chemistry QUESTIONS AND PROBLEMS (continued) * 22-13 From the standard potentials Tl1 1 e2 m Tl1s2 E0 5 20.336 V TlCl1s2 1 e2 m Tl1s2 1 Cl2 E0 5 20.557 V calculate the solubility product constant for TlCl. 22-14 From the standard potentials Ag2SeO41s2 1 2e2 m 2Ag1s2 1 SeO422 E0 5 0.355 V Ag1 1 e2 m Ag1s2 E0 5 0.799 V calculate the solubility product constant for Ag2SeO4. * 22-15 Suppose that we wish to produce a current of 0.0750 A in the cell Pt 0V31 12.9 3 1025 M2,V21 14.25 3 1021 M2 iBr2 10.0750 M2,AgBr1sat’d2 0Ag As a result of its design, the cell has an internal resistance of 4.59 V. Calculate the initial potential of the cell. * 22-16 The cell Pt k V1OH2 14 12.67 3 1024 M2,VO21 13.42 3 1022 M2, H1 14.81 3 1023 M2 y Cu2112.15 3 1022 M2 k Cu has an internal resistance of 4.17 V. What will be the initial potential if a current of 0.0750 A is drawn from this cell? * 22-17 The resistance of the galvanic cell Pt k Fe1CN2 64214.42 3 1022 M2,Fe1CN2 63218.93 3 1023 M2 y Ag115.75 3 1022 M2 k Ag is 3.85 V. Calculate the initial potential when 0.0442 A is drawn from this cell. 22-18 The following data are similar to those given in Example 22-1.14 cHCl, m g6 E E0 0.003215 0.9418 0.52053 0.22255 0.004488 0.9328 0.50384 0.22251 0.005619 0.9259 0.49257 0.22241 0.007311 0.9173 0.47948 0.22236 0.009138 0.9094 0.46860 0.22250 0.011195 0.9031 0.45861 0.22258 0.013407 0.8946 0.44974 0.22248 0.01710 0.8843 0.43783 0.22247 0.02563 0.8660 0.41824 0.22260 0.05391 0.8293 0.38222 0.22256 0.1238 0.7877 0.34199 0.22244 14D. A. MacInnes, The Principles of Electrochemistry, Table I, p. 187, New York: Reinhold, 1939. 597 Questions and Problems (a) Create a spreadsheet to calculate the standard electrode potential for the Ag-AgCl electrode using the method described in Example 22-1. Make columns for the activity coefficients and the standard potential. Calculate g values for H1 and Cl2 for each molality. Then find g6 at each molality. Use the measured values of E to find E0 at each molality. (b) Compare your values for the activity coefficients and standard potential with those of MacInnes, and if there are any differences between your values and those in the table above, suggest possible reasons for the discrepancies. (c) Use the Descriptive Statistics function of Excel’s Analysis Toolpak15 to find the mean, standard devi- ation, 95% confidence interval, and other useful statistics for the standard potential of the Ag-AgCl electrode. (d) Comment on the results of your analysis and, in particular, the quality of MacInnes’s results. Challenge Problems 22-19 As a part of a study to measure the dissociation constant of acetic acid, Harned and Ehlers16 needed to measure E0 for the following cell: Pt,H211 atm2 0HCl1m2,AgCl1sat’d2 0Ag (a) Write an expression for the potential of the cell. (b) Show that the expression can be arranged to give E 5 E 0 2 RT F ln gH3O1 gCl2 mH3O1 mCl2 where mH3O1 and mCl2 are the molal (mole solute per kilogram solvent) concentrations. (c) Under what circumstances is this expression valid? (d) Show that the expression in (b) may be written E 1 2k log m 5 E0 2 2k log g; where k 5 ln 10RT/F. (e) A considerably simplified version of the Debye-Hückel expression that is valid for very dilute solutions is log g 5 20.5!m 1 cm, where c is a constant. Show that the expression for the cell potential in (d) may be written as E 1 2k log m 2 k!m 5 E 0 2 2kcm (f) The previous expression is a “limiting law” that becomes linear as the concentration of the electrolyte approaches zero. The equation assumes the form y 5 ax 1 b, where y 5 E 1 2k log m 2 k!m ; x 5 m, the slope; a 5 22kc; and the y-intercept b 5 E 0. Harned and Ehlers very accurately measured the potential of the cell without liquid junction presented at the beginning of the problem as a function of concentration of HCl (molal) and temperature and obtained the data in the following table. For example, they measured the potential of the cell at 25°C with an HCl concentration of 0.01m and obtained a value of 0.46419 volts. 15S. R. Crouch and F. J. Holler, Applications of Microsoft® Excel in Analytical Chemistry, 3rd ed., Belmont, CA: Cengage Learning, 2017, pp. 44–47. 16H. S. Harned and R. W. Ehlers, J. Am. Chem. Soc., 1932, 54 (4), 1350–1357, DOI: 10.1021/ja01343a013.