Motor Starting Study Exercise 1. Exercise 1: System Setup – additional data for MS based on SC study files • Source and Branch Parameters Same as load flow and short-circuit studies. • Switching Motor Data for Static MS Element Accel T No Load Accel T Full Load St Load* Final Load T Begin T Final Mtr 1 2 4 100 100 0 0 Mtr 2 1 2 100 100 0 0 Syn 1 2 4 25 90 1 5 * Set starting category data for Category 1, 2, and 3. * Check data for Mtr4 and Mtr5. • Switching Motor Data for Dynamic Acceleration MS Element Mtr Model * Load Model H Mtr 1 Single 2, HV-HS-LT, MV500HP2P FAN 0.4 Mtr 2 Charac., LV-HS-HT, LV200HP2P a k**3 0.2 Syn 1 Single 2, HV-HS-HT, MV1000HP2P Recip. Comp .5 * In Motor Parameter Update Dialog, uncheck all boxes. • Starting Category Element Mtr Model Normal Mtr 1, Mtr 4 Back Up Mtr 2, Mtr 3 ETAP Workshop Notes 5.0 Page 1 of 5 Motor Starting Study Exercise 2. Exercise 2: Motor Starting Case 1 • Set up Study Case: MSCase-1 • Using Design Load, No load diversity factor. • Run simulation for 15 Seconds. • Include XFMR LTC in Pre-starting Load Flow, not during simulation. • Acceleration motor model based on Mechanical Load. • Use default settings on Adjustment and Alert Pages. Check all alert options with minimum violation span = 0.2 second. • Use Normal configuration. • Action sequence: Study Case: MSCase-1 Time Parameter Setting 0.2 second Start Mtr 5, at 60% load and ramp load from 60% to 100 % in 3 seconds. Switch on static load Load 2, Loading Category: Design 3 second Start all motors in the system belong to Normal Category • Run Static Motor Starting • Check results from OLV display, plot and report. • Is system voltage ok? Is the problem real or is it related to user entered acceleration time and sequencing? • Run Dynamic Motor Starting • Check results from OLV display, plot and report. • Is system voltage ok? • Can all the motors be started? • Solution to solve problem with motors failing to start (to increase acceleration torque): • Change starting sequence • Change pre-starting voltage • Use XFMR LTC • Use Starting device – What type of starter should be used here? (Cap) • Use larger motor • Try to change Mtr4 Starting Load from 60% to 40% -- Can Mtr 4 be started? • Check for low voltage problem – Is there a voltage problem? How to solve it? ETAP Workshop Notes 5.0 Page 2 of 5 Motor Starting Study Exercise 3. Exercise 3: Starting Devices • Run Dynamic Motor Starting • Configuration: Tie-Open, Study Case: MSCase-1 ( Change simulation duration to 15 seconds) • Check bus voltage for starting motors. (Mtr1 V = 5000 kVA 3 second Switch to Winter Load Category Exclude MV loads >= 1200 kVA Exclude MV loads >= 1000 kVA • Run Dynamic Motor Starting with MSCase-4 • Check results from OLV display, plot and report. • Check bus load change. • Check if any motors are started or stopped. ETAP Workshop Notes 5.0 Page 5 of 5 Element Accel T No Load Accel T Full Load St Load* Final Load T Begin T Final Mtr 1 2 4 100 100 0 0 Mtr 2 1 2 100 100 0 0 Syn 1 2 4 25 90 1 5 Element Mtr Model * Load Model H Mtr 1 Single 2, HV-HS-LT, MV500HP2P FAN 0.4 Mtr 2 Charac., LV-HS-HT, LV200HP2P a k**3 0.2 Syn 1 Single 2, HV-HS-HT, MV1000HP2P Recip. Comp .5 Element Mtr Model Normal Mtr 1, Mtr 4 Back Up Mtr 2, Mtr 3 Study Case: MSCase-1 Time Parameter Setting 0.2 second Start Mtr 5, at 60% load and ramp load from 60% to 100 % in 3 seconds. Switch on static load Load 2, Loading Category: Design 3 second Start all motors in the system belong to Normal Category Starting Device Current Control Capacitor at Bus/Terminal Speed Setting Type Speed Setting Type 0 400% Fixed 0 1000 kvar Fixed 2 400% Fixed 95 Remove 2 200 or 250% Ramp 95 400% Fixed 95 Remove Study Case: MSCase-2 Time Parameter Setting 0.2 second Start all motors in the system belongs to Backup Category Switch on static load Load 1, Design category 3 second Start OpenMOV and ClosedMOV Study Case: MSCase-3 Time Parameter Setting 0.2 second Switch on static load Load 1, Design category 3 second Start OpenMOV and ClosedMOV 5 second Start all motors in the system belonging to Backup Category Study Case: MSCase-4 Time Parameter Setting 0.2 second Switch to Normal Load Category Exclude MV loads >= 5000 kVA 3 second Switch to Winter Load Category Exclude MV loads >= 1200 kVA Exclude MV loads >= 1000 kVA