A maior rede de estudos do Brasil

Grátis
9 pág.
protese sobre implante Capitulo3

Pré-visualização | Página 5 de 5

sine qua non na obtenção de re-
sultados de excelência. Não se pode esgotar o assunto, nem
tampouco era a premissa deste capítulo, sugerindo-se ao lei-
tor um estudo detalhado de livros e a interação com bases de
sua experiência e tópicos de disciplinas interligadas.
Referências
1. Assif D, Fenton A, Zarb G et al. Comparative accuracy of implant im-
pression procedures. Int J Periodont Res Dent 1992;12:113-21.
2. Augsburger RM, Sodberg KB, Pelzner RB et al. Accuracy of casts from
three impression materials and effect of a gypsum hardener Oper Dent
1981; 6:70-4.
3. Brånemark PI, Zarb GA, Albrektsson T. Tissue-integrated prostheses –
osseointegration in clinical dentistry. Chicago: Quintessence; 1985,
4. Barrett MG, De Rijk WG, Burgess JO. The accuracy of six impression tech-
niques for osseointegrated implants. J Prosthodont 1993;2(2):75-82.
5. Carr AB, Stewart RB. Full arch implant framework casting accuracy: preli-
minary in vitro observations for in vivo testing. J Prosthodont 1993; 2:2-8.
6. Carr A. A comparison of impression techniques for five implant man-
dibular models. Int J Oral Maxillofac Impl 1991; 6(4):448-55.
7. Celletti R, Pameijer CH, Bracchetti G, Conath K, Persichetti G, Visani I.
Histologic evaluation of osseointegrated implants restored in nonaxi-
al functional occlusion with preangled abutments. Int J Period and Rest
Dent 1995; 15:562.
8. Craig RG. A review of properties of rubber impression materials. J Mich
Dent Assoc 1977;59:254.
9. Craig RG, O´Brien WJ, Power JM. Restorative dental materials. 5 ed. St
Louis: Mosby;1993. p. 283-335.
10. Finger W, Obsawa M. Accuracy stone casts produced from selected
addition type silicone impressions. Scand J Dent Res 1983;91:61.
11. Goll GE. Production of accurately fitting full arch implant frameworks.
Clinical Procedures. J Prosthet Dent 1991;66(Pt1):377-86..
12. Hobo S, Ichida E, Garcia LT. Osseointegration and occlusal rehabilita-
tion. Tokio: Quintessence; 1989. p.209-38.
13. Hosada J, Fusayama T. Distortion of irreversible hydrocolloid and mer-
captan rubber base impressions. J Prosthet Dent 1961;11:318-33.
14. Jorgesen KD. A new method of recording the elastic recovery of dental
impression materials. Scand J Dent Res 1976; 84:175.
15. Lewinstein I, Craig RG. Accuracy of impression materials measured
with vertical height gauge. J Oral Rehab 1990;17:303-10.
16. Linke BA, Nichols JI, Faucher RR. Distortion analysis of stone casts
made from impression materials. J Prosthet Dent 1985;54:794-802.
17. Lacy AH, Fukui H, Bellman T. et al. Time dependent accuracy of elas-
tomer impression materials. Part II: polyethers, polysulfides and poly
vinylsiloxanes J Prosthet Dent 1981; 45:329-33.
18. Misch CE. Implantología Contemporánea. Madrid: Mosby/Doyma Li-
bros ;1995.
19. Misch CE. Implantes dentários contemporâneos. 2 ed. São Paulo: Edi-
tora Santos; 2000. p. 576-85.
20. Misch CE. Prótese sobre implantes. 1ed. São paulo: Editora Santos;
2006. p.414-20.
21. Möllersten L, Lockowandt P, Linden LA. Comparison of strength and
failure mode of seven implant systems: an in vitro test. J. Prosth. Dent
1997;78: 582.
22. Rangert B. Practical guidelines based on biomechanical principles. In:
Palacci P, Ercsson I, Engstrand P, Rangert B. Optimal implant positio-
ning & soft tissue management for the Brånemark system. Cap. 2. Ger-
many: Quintessence; 1995. p.21-33.
23. Reisbick MII, Maeyas J. - The accuracy of highly filed elastomer impression
materials. J Prosthet Dent 1975;33:67-72.
24. Sendyk CL, Sendyk WR. Planejamento e biomecânica em prótese sobre
implantes osseointegrados. In: Gomes L.A. Implantes osseointegrados
– técnica e arte. Cap. 2. São Paulo: Editora Santos; 2002. p:11-32.
25. Spector MR, Donovan TE, Nicholls JI. An evaluation of impression techni-
ques for osseointegrated implants. J Prosthet Dent 1990;63:446-667..
26. Stockhouse JA. A comparison of elastic impression materials. J Pros-
thet Dent 1975;39:305-13.
27. Weigl P. Occlusal concept for implants with greater mechanical stability.
PraWissimo Journal – Practical aspects – Science – Implantology 2001
Feb: 17-25.