Buscar

Análise de Falhas

Prévia do material em texto

TxFalha
	
		Análise Falhas									PINTO/Luis H.
+ 55 41 3380-2250
luisterbeck@yahoo.com.br
			Nome do equipamento	COMPRESSOR A PARAFUSOS
			Quantidade de equip. avaliados		6	[eqpts]
			Taxa de utilização		16	[horas/dia]
					360	[dias/ano]
					5,760	[horas]
			Intervalo de análise	Início	01-01-03
				Fim	01-01-06
				Duração	17,536	[horas]
			Intervalo de confiança		5	[%]
			Componente/função	nj
[comp/eqpt]	kj
[falhas]	lj
[horas-1]		MTTFj		t¨%
						Mínimo	Máximo	Mínimo	Máximo	1%	10%	25%	50%
		1	MANCAIS FLUTUANTES	4	8	9.78E-06	3.43E-05	29,181	102,266	293	3,074	8,395	20,227
		2	SELO DE VEDAÇÃO	3	7	1.09E-05	4.14E-05	24,170	91,391	243	2,547	6,953	16,753
		3	VÁLVULA DE CONTROLE	1	3	1.04E-05	6.87E-05	14,563	96,541	146	1,534	4,190	10,095
		4	CONJUNTO DE PARAFUSOS	3	1	7.67E-07	1.17E-05	85,567	1,303,202	860	9,015	24,616	59,311
		5	MOTOR ELÉTRICO	1	1	2.30E-06	3.51E-05	28,522	434,401	287	3,005	8,205	19,770
		6	CONVERSOR DE FREQUÊNCIA	1	2	5.88E-06	5.30E-05	18,884	170,068	190	1,990	5,433	13,090
		7	BOMBA HIDRÁULICA	2	3	5.18E-06	3.43E-05	29,127	193,081	293	3,069	8,379	20,189
		8	CONTROLADOR DE SOBRE-TEMPERATURA	1	1	2.30E-06	3.51E-05	28,522	434,401	287	3,005	8,205	19,770
		9	CONJUNTO DE ENGRENAGENS	3	1	7.67E-07	1.17E-05	85,567	1,303,202	860	9,015	24,616	59,311
		10				nc	nc	nc	nc	nc	nc	nc	nc
		11				nc	nc	nc	nc	nc	nc	nc	nc
		12				nc	nc	nc	nc	nc	nc	nc	nc
		13				nc	nc	nc	nc	nc	nc	nc	nc
		14				nc	nc	nc	nc	nc	nc	nc	nc
		15				nc	nc	nc	nc	nc	nc	nc	nc
		16				nc	nc	nc	nc	nc	nc	nc	nc
		17				nc	nc	nc	nc	nc	nc	nc	nc
		18				nc	nc	nc	nc	nc	nc	nc	nc
		19				nc	nc	nc	nc	nc	nc	nc	nc
		20				nc	nc	nc	nc	nc	nc	nc	nc
Número de componentes similares instalados em cada equipamento
Número total de falhas observadas para o componente/função durante o intervalo de análise
Taxa de falhas individal
Mean Time To Fail individual
Tempo médio observado para a falha de k% da amostra de componentes
Intervalo de confiança estatístico
Análise
	
		Análise de Disponibilidade e Custo de Manutenção													PINTO/Luis H.
+ 55 41 3380-2250
luisterbeck@yahoo.com.br
		Nome do equipamento			COMPRESSOR A PARAFUSOS
		Período de análise		1	5,760	[horas]
			Componente/função	nj	MTTFj
[horas]	MTTRj
[horas]	lj
[horas-1]	kj
[falhas]	TTRj
[horas]	A%j
[%]		$LABOR
[$/horas]	$MAT.
[$/horas]	$LABOR
[$]	$MAT.
[$]	$TOTAL
[$]			TTRj
[horas]	Pareto%
[%]	Componente/função		$TOTAL
[$]	Pareto%
[%]	Componente/função
		1	MANCAIS FLUTUANTES	4	29,181	16.0	3.4E-05	0.8	12.6	99.781%	MANCAIS FLUTUANTES	26.00	6,175.00	328.46	4,875.54	5,204.00	MANCAIS FLUTUANTES		12.6	38.815%	MANCAIS FLUTUANTES		5,204.00	25.048%	MANCAIS FLUTUANTES
		2	SELO DE VEDAÇÃO	3	24,170	8.2	4.1E-05	0.7	5.9	99.898%	SELO DE VEDAÇÃO	26.00	3,200.00	152.42	2,287.79	2,440.21	SELO DE VEDAÇÃO		7.3	61.152%	CONJUNTO DE PARAFUSOS		4,526.75	46.836%	CONVERSOR DE FREQUÊNCIA
		3	VÁLVULA DE CONTROLE	1	14,563	2.5	6.9E-05	0.4	1.0	99.983%	VÁLVULA DE CONTROLE	26.00	2,450.00	25.71	969.00	994.71	VÁLVULA DE CONTROLE		5.9	79.165%	SELO DE VEDAÇÃO		2,652.77	59.604%	CONJUNTO DE PARAFUSOS
		4	CONJUNTO DE PARAFUSOS	3	85,567	36.0	1.2E-05	0.2	7.3	99.874%	CONJUNTO DE PARAFUSOS	26.00	12,200.00	189.02	2,463.75	2,652.77	CONJUNTO DE PARAFUSOS		2.5	86.921%	MOTOR ELÉTRICO		2,440.21	71.349%	SELO DE VEDAÇÃO
		5	MOTOR ELÉTRICO	1	28,522	12.5	3.5E-05	0.2	2.5	99.956%	MOTOR ELÉTRICO	26.00	7,350.00	65.63	1,484.31	1,549.94	MOTOR ELÉTRICO		1.1	90.201%	CONVERSOR DE FREQUÊNCIA		1,616.99	79.132%	CONJUNTO DE ENGRENAGENS
		6	CONVERSOR DE FREQUÊNCIA	1	18,884	3.5	5.3E-05	0.3	1.1	99.981%	CONVERSOR DE FREQUÊNCIA	26.00	14,750.00	27.76	4,498.99	4,526.75	CONVERSOR DE FREQUÊNCIA		1.0	93.239%	VÁLVULA DE CONTROLE		1,549.94	86.592%	MOTOR ELÉTRICO
		7	BOMBA HIDRÁULICA	2	29,127	2.5	3.4E-05	0.4	1.0	99.983%	BOMBA HIDRÁULICA	26.00	3,550.00	25.71	1,404.07	1,429.77	BOMBA HIDRÁULICA		1.0	96.277%	VÁLVULA DE CONTROLE		1,429.77	93.473%	BOMBA HIDRÁULICA
		8	CONTROLADOR DE SOBRE-TEMPERATURA	1	28,522	1.5	3.5E-05	0.2	0.3	99.995%	CONTROLADOR DE SOBRE-TEMPERATURA	26.00	1,750.00	7.88	353.41	361.28	CONTROLADOR DE SOBRE-TEMPERATURA		0.9	99.069%	CONJUNTO DE ENGRENAGENS		994.71	98.261%	VÁLVULA DE CONTROLE
		9	CONJUNTO DE ENGRENAGENS	3	85,567	4.5	1.2E-05	0.2	0.9	99.984%	CONJUNTO DE ENGRENAGENS	26.00	7,890.00	23.63	1,593.36	1,616.99	CONJUNTO DE ENGRENAGENS		0.3	100.000%	CONTROLADOR DE SOBRE-TEMPERATURA		361.28	100.000%	CONTROLADOR DE SOBRE-TEMPERATURA
		10	nc	nc	nc		nc	nc	nc	nc	nc			nc	nc	nc	nc		nc	100.000%	nc		nc	100.000%	nc
		11	nc	nc	nc		nc	nc	nc	nc	nc			nc	nc	nc	nc		nc	100.000%	nc		nc	100.000%	nc
		12	nc	nc	nc		nc	nc	nc	nc	nc			nc	nc	nc	nc		nc	100.000%	nc		nc	100.000%	nc
		13	nc	nc	nc		nc	nc	nc	nc	nc			nc	nc	nc	nc		nc	100.000%	nc		nc	100.000%	nc
		14	nc	nc	nc		nc	nc	nc	nc	nc			nc	nc	nc	nc		nc	100.000%	nc		nc	100.000%	nc
		15	nc	nc	nc		nc	nc	nc	nc	nc			nc	nc	nc	nc		nc	100.000%	nc		nc	100.000%	nc
		16	nc	nc	nc		nc	nc	nc	nc	nc			nc	nc	nc	nc		nc	100.000%	nc		nc	100.000%	nc
		17	nc	nc	nc		nc	nc	nc	nc	nc			nc	nc	nc	nc		nc	100.000%	nc		nc	100.000%	nc
		18	nc	nc	nc		nc	nc	nc	nc	nc			nc	nc	nc	nc		nc	100.000%	nc		nc	100.000%	nc
		19	nc	nc	nc		nc	nc	nc	nc	nc			nc	nc	nc	nc		nc	100.000%	nc		nc	100.000%	nc
		20	nc	nc	nc		nc	nc	nc	nc	nc			nc	nc	nc	nc		nc	100.000%	nc		nc	100.000%	nc
		Sistema			3,076.1	9.5	3.3E-04	3.4	32.5	99.435%				846.21	19,930.21	20,776.43
TTR
	MANCAIS FLUTUANTES	0.3881502043
	CONJUNTO DE PARAFUSOS	0.6115241716
	SELO DE VEDAÇÃO	0.7916490588
	MOTOR ELÉTRICO	0.8692094641
	CONVERSOR DE FREQUÊNCIA	0.902010291
	VÁLVULA DE CONTROLE	0.9323906482
	VÁLVULA DE CONTROLE	0.9627710055
	CONJUNTO DE ENGRENAGENS	0.9906927514
	CONTROLADOR DE SOBRE-TEMPERATURA	1
	nc	1
	nc	1
	nc	1
	nc	1
	nc	1
	nc	1
	nc	1
	nc	1
	nc	1
	nc	1
	nc	1
TTRj
[horas]
Pareto%
[%]
TTRj - [horas]
Pareto de TTR
12.6329888619
7.2700743402
5.8624616688
2.5243313681
1.0675570343
0.9887788542
0.9887788542
0.9087592925
0.3029197642
0
0
0
0
0
0
0
0
0
0
0
$
	MANCAIS FLUTUANTES	0.2504762876
	CONVERSOR DE FREQUÊNCIA	0.4683552925
	CONJUNTO DE PARAFUSOS	0.5960369954
	SELO DE VEDAÇÃO	0.7134880921
	CONJUNTO DE ENGRENAGENS	0.7913159998
	MOTOR ELÉTRICO	0.865916873
	BOMBA HIDRÁULICA	0.934734016
	VÁLVULA DE CONTROLE	0.9826109496
	CONTROLADOR DE SOBRE-TEMPERATURA	1
	nc	1
	nc	1
	nc	1
	nc	1
	nc	1
	nc	1
	nc	1
	nc	1
	nc	1
	nc	1
	nc	1
$TOTAL
[$]
Pareto%
[%]
$TOTAL - [$]
Pareto de Custos Totais de Manutenção
5204.0018492791
4526.7468417301
2652.7693481229
2440.213922934
1616.9857011586
1549.9394600216
1429.774223214
994.7115273535
361.2823054044
0
0
0
0
0
0
0
0
0
0
0

Continue navegando