Prévia do material em texto
PAMUKKALE ÜNİVERSİTESİ Mühendislik Bilimleri Dergisi | PAMUKKALE UNIVERSITY Journal of Engineering Sciences Araştırma makalesi | Research paper Cilt | Vol: XX • Sayı | No: X • ss | pp: XXXX-XXXX • Yıl | Year: 20XX 1 This article published under the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 (CC BY-NC-SA) licence. Numerical evaluation of the bending performance of precast beam-column connections Fırat Kıpçak A R T I C L E I N F O A B S T R A C T Dates: Received: 25.01.2026 Accepted: 04.05.2026 Doi: 10.65206/pajes.1871118 Corresponding author: (firatkipcak@yyu.edu.tr) Author addresses: Department of Construction, Van Vocational School, Van Yüzüncü Yıl University, Van, 65040, Türkiye (firatkipcak@yyu.edu.tr) Context—Precast beam-column connections directly affect the behavior of structure. These connections form the resistance of the structural system by transferring forces between elements. In recent years, there has been an increase in the use of precast structures. Performance issues observed during earthquakes have revealed the need for further research in this field. In the earthquakes that occurred in our country in 2023, it was determined that pin connections in precast structures were damaged. Objective—The weakest points in the structure were found to be the connections in response to seismic effects. This situation was found to be significant in the structure. The damage occurring in the connections was seen to cause major damage throughout the structure. This made it necessary to reevaluate the connections. The study numerically investigated the bending performance of six different connection types: monolithic, semi-prefabricated, single-pin, double-J-pin, double-pin, and both single-pin and cleat angle. Method—Connection types found in the literature and commonly used today were investigated. The structural performance, failure behavior, load and displacement capacities, and damage mechanisms of the connection types were investigated under vertical load using ABAQUS software. For this purpose, six connection types were considered. Nonlinear behaviors were considered to ensure the correct use of concrete and steel materials. In this context, separate material properties were defined for the pin, cleat angle, plate, and bolt steel materials and evaluated in the study. Results—The capacity increased as the number of connection elements increased from precast to monolithic connection. The semi-prefabricated connection reached the highest capacity with the support of the gusset. The significance effect of the cleat angle used in the connection was observed. The side bolt connecting the column was observed to behave like a monolithic connection until it reached the shear capacity. The use of gussets was effective in precast connections. More damage was observed in concrete elements in monolithic structures. Conclusion—The capacity was increased thanks to a cleat angle to the single-pin connection and the high ratio of the gusset distance to the beam. Using a cleat angle to pin connections increased capacity by 2.18 times. Using two pins increased capacity by 1.21 times compared to using a single pin. Key Words—Beam-Column Connection, Cleat Angle Connection, Dowel Connection, Precast Concrete. https://orcid.org/0000-0003-3849-7545 F. Kıpçak Pamukkale University Journal of Engineering Sciences, XX(X), XXXX-XXXX, 20XX 2 I. INTRODUCTION recast structures are structural systems whose load-bearing elements are manufactured under controlled conditions. These structures are often preferred in industrial settings due to advantages such as ensuring quality control and shortening construction time. Precast structures are also preferred for factory buildings, sports structures, and multi-story building types. With the recent widespread use of precast structures, the number of studies on connection details has increased [1]–[3]. The fact that the elements are not connected with monolithic concrete reduces the earthquake resistance of precast structures. One of the most critical factors determining the behavior of these systems under seismic loads is the design of the connection details. Weak connections directly affect structural safety. The separate fabrication of structural members complicates the safe and continuous transfer of vertical and horizontal loads [4]. In this context, connection details are considered important sections where energy consumption, stiffness, and damage mechanisms are concentrated. In recent years, the damage caused to beam-column connection details because of earthquakes in Türkiye has been found to reduce structural performance. The lack of adequate safety in the design of connections can lead to brittle fracture mechanisms and sudden collapses. Recent studies focusing on the lack of connections in prefabricated industrial buildings have attracted attention to these problems [5]. In the earthquakes that occurred in Kahramanmaraş-Pazarcık and Elbistan on February 6, 2023, it was determined that significant damage and collapses occurred in a significant portion of precast structures because of damage to the connections [5]–[8]. Observed connection failures have raised questions about the adequacy of existing precast connection designs in terms of rigidity, strength, and ductility capacity [2], [9], [10]. In reinforced concrete systems, beam-column connections are classified as fully rigid, semi-rigid, and hinged connections depending on the moment transfer mechanism. In monolithic systems, connections generally have moment-transferring and fully rigid characteristics. In these systems, when the moment capacity is exceeded with increasing load, a plastic hinge occurs. However, in precast structures, connections change from fully rigid to hinged depending on the connection elements. In semi- prefabricated connections, the continuity of the structural elements is ensured after construction by casting concrete or grout on place [11]. In precast connections, mechanical fasteners (bolts, plates, cleat angle, etc.) are used. These elements are highly preferred due to the fast construction time and ease of repair after an earthquake. These connections were considered in the study because they contain uncertainties in terms of moment transfer capacity. Pin connections are a widely used connection type in our country. Load transfer is provided by the tensile and shear capacities of the pins and the interaction between the plate and concrete. In literature, pin connections are considered to be semi-rigid connections that partially transfer moments [4]. The number of pins in the connection such as pin diameter, prestressing force, concrete cover thickness, reinforcement arrangement and steel elements directly affect the behavior and capacity. In pinned connections, the prestressing force may increase the initial stiffness of the connection but may not significantly change its ultimate strength [12]. Previous studies have reported that insufficient concrete cover thickness relative to the pin diameter leads to a transition in fracture behavior from ductile to brittle [11], [13]. The other parameter, the grout, has been observed in literature research to reduce rotational and impact effects by restricting the movement of the beam [14]. The reinforcement around the pin has been observed to reduce the risk of brittle fracture by preventing the crushing of concrete [14]. Another factor affecting connection performance is the elastomeric pads used under the beams in shear beams, which reduce fractures on the column and beam contact surfaces [5]. Under various loads, connections that reduce material discontinuities to a minimum and enable load transfer are required. Recent research has led to the development of connection types such as cleat angle, steel plate supports, or fixedbehavior to enhance the performance of pinned connections [15]–[18]. This approach aimed to achieve reinforced connections. These connections aimed to reduce stress and damage accumulation, thereby increasing capacities. A literature review has determined that studies on the behavior of combinations are limited [16]–[18]. Most studies have focused on determining general behavior. Due to the large number of parameters affecting the combination and the high cost of experiments, comprehensive comparisons are often not possible. A limited number of studies have been reported on the comparison between monolithic connections and reinforced precast connections. There is a lack of numerical studies that systematically examine the cleat angle and pin variables. Cleat angle, a simple but effective steel reinforcement, changes the connection behavior and contributes to in-plane bending and out-of-plane overturning resistance [16]–[18]. Studies conducted on this subject have shown that connections play a major role in the durability and performance of structures. Also, reinforcement methods have been reported to improve overall performance [13], [16], [19]. In some studies, connection behavior has been evaluated only with experimental results, and detailed data such as stress distributions, damage mechanisms, and deformation changes have not been obtained. In contrast to experimental studies, capacity and mechanical results can be easily obtained through numerical studies [20]–[23]. A numerical perspective on the performance of reinforced concrete beam-column connections under monotonic loading was presented. The finite element method was considered, and numerical analyses were performed using ABAQUS software in the study. Elastoplastic properties were defined for concrete and steel materials. The Concrete Damage Plasticity (CDP) model was used for concrete. This allowed for a realistic determination of the stress change and damage development of concrete under compression and tension. Steel connection elements and reinforcements are defined as elastic up to yield strength and then as plastic. The main contribution of this study is as follows: An investigation of the flexural behavior of fix different connection types used for precast beam-column joints. The study includes not only conventional pinned connections but also other precast connections. These include monolithic, semi-prefabricated, single-pin, double J-pin, double-pin, and single-pin connections with cleat angles for beam-column joints. Changes in the stiffness and stress distribution of the reinforced connections under the same loading conditions were evaluated. Compression and tension damage occurring in the concrete at the connection regions and stress/deformation in the steel connections and reinforcements were observed. Stress distributions in the connection elements, plastic deformations, stiffness changes, and damage information, which are difficult to obtain in experimental studies, were obtained in detail in the numerical study. The study contributes to the literature and provides important results regarding connection details during the design process. Some notable findings have been observed. The semi-prefabricated connection performed remarkably high due to its support from the gusset. Increasing the number of pins in the connection was more effective than extending a single pin into the column. The cleat angle connection demonstrated high effectiveness. Detailed conclusions are presented in the findings section. II. NUMERICAL INVESTIGATION A. Beam-Column Connection Models Literature research has clearly demonstrated that precast connections involve some uncertainties [10], [24]. In this context, P F. Kıpçak Pamukkale University Journal of Engineering Sciences, XX(X), XXXX-XXXX, 20XX 3 the load-displacement capacities and fracture mechanics of six different types of connections commonly seen in practice were numerically investigated. Pin-connected, semi-prefabricated methods, cleat angle connections were considered [2], [15], [25], [26]. Details of the combinations are provided in Fig. 1. The term “semi-prefabricated connection” refers to connection details in which part of the connection between precast elements is completed through in-situ applications (e.g., grout or cast-in- place concrete). As the focus of this study is connection behavior, the term “semi-prefabricated connection” was used for the SP model and refers to two separate concrete sections that are gradually separated at the point where the beam connects to the column. In this study, the term “reinforced connections” refers to additional structural steel elements used to improve load transfer at the connection and increase strength and stiffness. The use of steel plates, cleat angle elements, and an increased number of pins were considered as reinforcement strategies to enhance connection performance. The properties of the beam- column connection model were given in Table 1. The REF-coded monolithic combination was considered as a reference. In the reference combination, the continuity of the reinforcement produced with monolithic concrete was ensured in the beams and column. This model does not require a gusset. There is interlocking between the column longitudinal reinforcement and the beam reinforcement. The beam reinforcement is bent to form a right angle within the column. The joint is a rigid type. The SP coded model is a semi-prefabricated beam-column connection. This is a common model in the production of prefabricated elements. Half of the reinforced concrete element is precast and transported to the construction site, while the remaining part is completed in situ by casting concrete. The reinforcement in this model is made in the same way as in the reference model. Cold joints have been provided between concrete elements. In this model, the rigidity and performance of the step-shaped connection were measured. In the model coded 2JP, only two J- shaped pinned joints extending into the gusset were determined. The pins were fixed to the beam with the main plate, additional plate, and nut. Additionally, the height within the beam was filled with grout mortar. This was attempted to prevent small displacements and rotations. In this model, two pins were used to restrict rotation. In the PG coded model, a single pin was designed to extend into the gusset and column. This type of connection is commonly used. It is a pinned connection with a dowel [5]. Grout mortar was used between the pin and the beam. The extension of the pin to the column in the connection is designed to reduce bonding effect, particularly from short gussets to a low level. Another model commonly used in practice is the two-pin PG model. In this model, two pins are used to restrict out-of-plane rotation and displacement on the support. In this study, the two-pin condition was considered using the 2PG model. The main and additional plate connecting the pin to the beam was used. Rotation and translation are restricted by only one pin. The PA code connection is a single-pin connection extending to the column and a connection with an added cleat angle. A cleat angle was added to this connection to strengthen the PG connection. The cleat angle is fixed inside the column with side bolts, additional plates, and nuts. In this connection, rotational and lateral movements have been attempted to be more effectively restricted. This has been attempted to achieve a rigid connection close to a monolithic connection. The reinforcement effects were investigated in this connection. The reference points shown in Fig. 1 define the boundary conditions. At reference point RF-1, there is a fixed support; at RF-3, it is movable vertically but restrained in rotation and displacement in other directions; at RF-2, displacement is restrained, and only vertical displacement is allowed.Capacity graphs were obtained by comparing the vertical reaction force at point RF-1 with the displacement data at point RF-2. B. Type of Analysis and Material Properties In finite element analyses, both elastic and plastic properties are used to define the mechanical properties of concrete. The CDP model, which is widely accepted in literature, was taken into (a) (b) (c) (d) (e) (f) Figure 1. Beam-column connection models: (a) REF, (b) SP, (c) 2JP, (d) PG, (e) 2PG, (f) PA. Table 1. Beam-column connection models Connection Type Model properties REF The reference model is a monolithic connection with concrete and mortar continuity SP Different from the reference model, the concrete beam and column are modeled as two separate elements at their connection point. The connection is achieved through a cold joint 2JP This is a hinged connection with two J-type pins, limited within the gusset PG This is a single-pin hinged connection, arranged to extend from the gusset toward the column 2PG Different from the PG model, two pins were used. PA This is a hinged connection with a single pin, supplemented by a cleat angle, where the gusset is arranged to extend toward the column. F. Kıpçak Pamukkale University Journal of Engineering Sciences, XX(X), XXXX-XXXX, 20XX 4 account. Compression crushing and tension softening mechanisms can be defined using the CDP model [4], [19], [23], [27]. Elastic behavior is defined by the elastic modulus and Poisson's ratio, while CDP parameters are used for plastic properties. Different experimental studies have shown that the use of the CDP model in numerical analyses is appropriate [28], [29]. For the CDP model, data from stress-strain and damage- inelastic strain curves are primarily used. Additionally, five different plastic parameters are considered in the model. The concrete compression strength is taken as 𝑓𝑐𝑘 = 35 MPa. The modulus of elasticity (𝐸𝑐 = 5000√𝑓𝑐𝑘) was obtained from the equation and calculated as 𝐸𝑐 = 29580 MPa [30]. The Poisson's ratio is typically taken as 𝜐 = 0.2 and the design density as ϒ = 2500 kg/m³. The uniaxial tension strength (𝑓𝑐𝑡𝑘 = 0.35√𝑓𝑐𝑘) was calculated as 2.07 MPa. In addition, the equation 0.4fc provided in TS500 [31] was used to calculate the elastic compressive strength of the concrete, which resulted with 14 MPa. The concrete model defined in the Chinese Code-GB50010 regulation was used for the compression and tension behavior of the concrete [32]. This regulation allows for the calculation of stress and strain values for concrete with a known modulus of elasticity, in accordance with the targeted compressive and tension strength. Detailed equations for the calculated values are provided in Appendix C of the regulation and are therefore not provided here. When comparing the regulation with Eurocode-2 and experimental studies in different investigations, the Chinese Code-GB50010 regulation has been found to give consistent results [32], [33]. Accordingly, the values obtained and defined during the analysis process are given in Fig. 2. Figure 2a shows the concrete stress-strain curve defined in the Chinese Code- GB50010. In the graph, 𝑓𝑐.𝑟 represents the peak compressive strength of concrete, 0.5𝑓𝑐.𝑟 represents 50% of the peak compressive strength, 𝑓𝑐.𝑟 represents the strain at peak compressive strength, 𝜀𝑐𝑢 represents the strain at 50% of the compressive strength, 𝑓𝑡.𝑟 represents the peak tensile strength of the concrete, and 𝜀𝑡.𝑟 represents the strain at peak tensile strength. For compression behavior, multi-point values were obtained to capture the parabolic peak strength region and the after-peak region. The point after the peak was considered as the start of damage. Damage increased as deformations increased after the peak (Fig. 2). For the behavior of concrete under tension, a linear curve up to the elastic limit and a subsequent decrease curve involving cracking-softening and increasing strain was calculated (Fig. 2). In order to define the curves obtained from the equations in the Abaqus software, the elastic part was defined by the elastic modulus and Poisson's ratio, while the plastic part was defined by the stress-inelastic strain curves. Damage parameters inelastic strain curves were defined to determine the damage level following peak stress. For this purpose, the compression damage (dc) and tension damage (dt) parameters were calculated within the range of 0 to 1 [27], [34]. Here, 0 = undamaged, 1 = fully damaged state. Inelastic deformation is calculated by taking the difference between total deformation and elastic deformation. The main plastic parameters determined for the CDP model in this study are the dilation angle (ψ), eccentricity (e), the ratio of the yield strength under biaxial compression to the yield strength under uniaxial compression (f = 𝑓𝑏0/𝑓𝑐0), the ratio of tension and compression meridians (Kc), and the viscosity (μ) parameter. Here, the reference stress corresponds to the stress level at which inelastic (plastic) deformations begin, rather than a distinct yield point as in steel. For the dilatation angle, a range of 30°–40° is recommended for normal-weight and normal-strength concrete. In this study, this value was considered as ψ = 35𝑜. This value provided quite consistent results for the concrete specimens experimentally investigated in the study by Rewers [29]. To improve viscosity convergence, a very small value such as 0 or 10−5 is generally used. Since using a high viscosity value changes the results, sensitivity analyses are often necessary. Eccentricity was defined as 0.1, f = 𝑓𝑏0/𝑓𝑐0 = 1.16, Kc = 2/3, and viscosity was defined as 0. These values have been assumed as default for normal- strength concrete in many experimental studies, and the analysis results have been reported to be consistent [27]–[29], [35]. The CDP model accurately captures behaviors such as loss of stiffness in concrete, energy consumption, and permanent deformations. Consequently, when the specified data for fc = 35 MPa was defined in Abaqus, the behavior of concrete under both monotonic and cyclic loading could be modeled consistently. Structural steel and reinforcing steel are materials that conform to TS 708, TS EN 10025, and Eurocode 3 standards, with yield strengths of 235 MPa (S235) and 420 MPa (B420C), respectively [36], [37]. The stress-strain values for S235 steel were calculated using the equations provided by Yun and Gardner [38]. The nut steel was also a grade 8.8 material. For the grade 8.8 nut steel, the data obtained from experiments conducted at 25°C on an M24 bolt/nut in the 8.8 steel grade used by Saedi Daryan and Ketabdari in 2019 was used [39]. This material complies with the Regulation on the Design Rules of Calculation and Construction Requirements of Steel Structures Codes-2016 (DRCCRS-2016) [40]. Furthermore, the stress-strain values of the reinforcing steel comply with the B420C steel specified in the Turkish Building Earthquake Regulation (TBEC-2018) [41]. Steel material properties are quite important for obtaining the accurate behavior of reinforced concrete. In particular, the stress-strain curve after yield stress gives accurate behavior. While linear behavior is observed in the linear elastic region, hardening and softening regions are obtained with increasing stress after yield stress (Fig. 3). The Poisson's ratio was taken as 𝑣 = 0.30 for all steels. The elastic modulus was defined as 200 GPa for B420C steel and 210 GPa for S235 and 8.8 steels. B420C steel is ductile, (a) (b) (c) Figure 2. Concrete material curves. (a) The concrete curve defined in the Chinese GB 50010 regulation (b) Compressive behavior defined in Abaqus (c) Tensile behavior defined in Abaqus. F. Kıpçak Pamukkale University Journal of Engineering Sciences, XX(X),XXXX-XXXX, 20XX 5 while 8.8 and S235 steels have brittle properties. All steels are described using a multi-linear elastic-plastic model. Elastic behavior is defined by the elastic modulus, while plastic behavior is defined by inelastic deformation. Steel elements in Abaqus finite element software exhibit both extension under load and necking behavior, as they do in reality. In this context, defining engineering stress–strain values directly in Abaqus may lead to inaccurate results. Therefore, true stress and true inelastic strain values were adopted for steel material definition. To accurately represent the tensile behavior of steel, engineering stress–strain curves must be converted into true stress–strain curves [4]. This converted data is used to determine the plastic behavior of steel. The values defined for steels in this regard are given in Fig. 3. The unit volume mass for all steels was taken as 7.85 (t/m³). The displacement values for triaxial stress, strain ratio, and damage assessment at the point of failure/rupture were defined as 0. However, the fracture strain included in the ductile damage material definitions was defined as 0.18811 for S235 steel, 0.07486 for B420C steel, and 0.19273 for 8.8 steel. Abaqus solves plastic behavior using the equivalent stress yield criterion and the assumption of isotropic hardening [27]. This approach accurately calculates the behavior of steels under multi-axis stress. Defining steel in this manner in Abaqus is widely preferred in various studies because it provides computationally efficient results that are consistent with experimental validations [4], [23], [27], [38]. C. Element Details and Mesh Sizes The dimensions and reinforcement details for the columns and beams are shown in Fig. 4. Figure 5 shows the geometric details of the elements and the mesh pattern. The column was modeled according to the minimum element size defined in TBDY-2018. The beam was modeled with dimensions suitable for the column and a length of 1000 mm. The column and beam elements and the gusset section have ratios commonly used in practice. The mesh size for these elements is 50 mm. A finer mesh was used in the part where the pin hole is located. The pin shown in Fig. 5c was used in the single-pin hinged PG and PA models. The mesh size of this element is 10 mm. It extends to the gusset and column with its curved shape. The cleat angle shown in Fig. 5f was used for reinforcement in the PA model. This attempted to achieve a more rigid joint than a hinged joint. The cleat angle mesh size is 15 mm. The main plate shown in Fig. 5g was used only in the 2JP model. Since the distance between the two pins is short, the main plate was made from a single part. The mesh size is 15 mm. The grout mortar shown in Fig. 5h was used in all pinned connections. The grout ensures that the pin remains stable within the beam. The inner surface of the grout was tied with a pin. The outside surface is smooth and exhibits cold joint properties, interacting with the beam. The mesh size is 15 mm. The side bolt was used to connect the cleat angle to the column in the PA model. Side bolt has reinforcement features. The body section is embedded in the column. It is connected with nuts at both ends. The main plate shown in Fig. 5j was used only in the PG model. The mesh size is 15 mm. The J-shaped pin shown in Fig. 5l was used only twice in the 2JP model. The bond effect on the pin placed in the gusset was taken into account. Two pins were used to try to improve the performance of the joint. The main plate, additional plates, and nuts were used to reinforce the beam. The J-pin was extended to the center of the gusset. The mesh size is 10 mm. The nut shown in Fig. 5m was used in each pinned model. The M25 nut was considered sufficient for the design. The mesh size is 6 mm. All concrete and structural steel elements were modeled with the C3D8R element label. The geometric order was defined with a linear, hex-type reduced integration model. All reinforcements were defined with the Truss element label and modeled embedded inside solid elements. In the literature, the height of columns in single-story precast structures is generally 6–8 m, and the minimum column dimensions given in TBDY-2018 were found to be insufficient against the applied loads [42]. However, the column height used in this study was 2.4 m, and it was shorter. According to the purpose of the study, the focus was on the behavior of different connection types. As presented in the Results and Discussion section, the first damage occurred in the connection regions in all models, and the behavior was found to be controlled by the connection. Considering connection sensitivities, the recommendation made in the study by Senel and Palanci [42], which is commonly preferred in practice, particularly for tall and slender structures, to select column and beam elements with larger cross-sections may be proposed. Figure 6 shows the reinforcement details for the elements. These details were arranged to ensure the strength and performance of the structural elements by providing ductile failure. In the REF model, the beam reinforcements were placed inside the column and secured by forming a right angle. In this model, no cuts were made in the reinforcements or concrete. The reinforcements were constructed in the same way in the SP model. However, the concrete was modeled as semi-prefabricated. The concrete part at the beam-column connection interacts with the elements via a cold joint. The structure was modeled as a step-shaped (a) (b) (c) Figure 3. True stress-inelastic strain curves of steel defined in Abaqus (a) B420C reinforcing steel (b) S235 steel (c) 8.8 steel. (a) (b) Figure 4. Element properties (dimensions in mm) (a) Column detail (b) Beam detail. F. Kıpçak Pamukkale University Journal of Engineering Sciences, XX(X), XXXX-XXXX, 20XX 6 connection at the beam contact. In the 2JP model, two holes were made in the beam for pins. The beam reinforcement remains inside the beam solid element. No reinforcement connection was provided between the beam and the column. Similarly, the beam and column elements were modeled in the PG model. A single pin hole was created at the center of the beam. Unlike the PA model, the beam was connected to the column through cleat angle elements. In addition, a side bolt embedded in the column was used to establish the column connection. There are main and additional plates and nuts on the left and right sides of the bolt. Table 2 shows the connection types and their characteristics. Except for the SP and REF models, only friction interaction was defined between all column and beam elements and between steel and concrete elements. In the SP model, cold joints were defined between elements in the semi-prefabricated section and between the beam and the grout mortar. The “hard contact” definition allows for the transfer of pressure between contacting surfaces. It is defined to allow separation after contact. This definition was used to prevent the surfaces from penetrating each other and to achieve physically realistic contact. (a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) Figure 5. Element details and mesh sizes ( in mm): (a) Column-C35 (in REF model), (b) Column-C35 (in SP and all pinned models), (c) Pin-B420C (in PG and PA models), (d) Beam-C35 (in PG and PA models), (e) Beam-C35 (2JP model), (f) Cleat angle-S235 (in PA model), (g) Main plate-S235 (2JP model), (h) Grout mortar-C35 (in all pinned models), (i) Side bolt-B420C (PA model), (j) Main plate-S235 (PG model), (k) Additional plate-S235 (in all pinned models), (l) J Pin-B420C (2JP model), (m) Nut-8.8 (in all pinned models). (a) (b) (c) (d) (e) (f) Figure 6. Element reinforcementdetails: (a) REF, (b) SP, (c) 2JP, (d) PG, (e) 2PG, (f) PA. F. Kıpçak Pamukkale University Journal of Engineering Sciences, XX(X), XXXX-XXXX, 20XX 7 III. RESULTS and DISCUSSION According to the analysis results, the vertical (𝑦) reaction force under the column (point RF-1) and the deflection values at the beam end (point RF-2) were calculated. Based on the results, the graph in Fig. 7 was drawn. A summary table of the analysis results is provided in Table 3. Upon examining the graphs, it is clearly seen that different joint configurations have significant effects on the load-carrying capacity. In the REF monolithic connection, the ultimate force was obtained as 67 kN. This model has no discontinuities in concrete and reinforcement. Fu is the ultimate load capacity. The SP model exhibited an increase of 28 kN compared to the reference model, reaching a final load value of 95 kN. It also showed higher stiffness and ductility values, demonstrating the best overall performance among the investigated models. This behavior can be attributed to the short beam length of 1000 mm. With the addition of gusset plates to the short beam, the bending moment decreased while the vertical reaction force increased. In longer beams, where torsional effects become more significant, the capacity is not expected to exceed that of the monolithic connection (REF model). Because the concrete at the joint was weakened by a gradual cold joint connection. The disadvantageous effect was reduced by placing this region above the gusset. The presence of a stepped structure after the gusset distance ends may reduce the integrity of the connection. Different results may occur in connections where moment is decisive. The SP model showed a relative increase of 41.79%. Significant capacity losses were observed in the 2JP and PG connections compared to the reference model. In the 2JP model, the ultimate force decreased to 40 kN, resulting in a difference of 27 kN and a high relative decrease of 40.3% compared to REF. Similarly, the PG model exhibited the lowest performance with a ultimate force value of 33 kN. The difference reached 34 kN, while the relative difference reached 50.75%. These results demonstrate how pin detailing influences the load-transfer mechanism and structural stiffness. The single-pin connection (PG) was found to significantly reduce load capacity, whereas the use of two pins resulted in a 6 kN increase in capacity. This study did not examine the rotation and out-of-plane overturning mechanism. Considering this behavior, it can be expected that the two-pin connection (2JP) will be more resistant than the single- pin connection (PG). The ultimate capacity of the 2PG model was determined to be 46 kN. This represents a 39% increase compared to the single-pin PG model and a 15% increase compared to the 2JP model. This increase was found to be significant. The pin extending from the gusset to the column was found to be effective at the connection and its effect became evident after a displacement of approximately 20 mm at the beam end. The PA single-pin and cleat angle connection had the closest capacity to the REF connection. An ultimate force of 72 kN was measured in this model. The difference was 5 kN and the relative difference was 7.46% (Table 3). The reason this connection exceeded the REF connection was similar to the situation in the SP connection. Since gussets were also used in this connection, the load transfer caused by the vertical deflection at the beam end was reinforced by the gussets, resulting in a high measurement under the column. This connection exhibited behavior quite similar to the reference model in terms of stiffness and displacement amount (Fig. 7). The load capacity and performance were found to be significantly higher compared to the 2JP and PG connections without a cleat angle. The importance of the cleat angle joint used in the connection was observed. The side bolt connecting the column behaved like a monolithic joint until it reached its shear capacity. In general, the findings obtained from the graphs showed that changes in the connections could cause significant differences in capacity. Figure 8 shows the stress distributions occurred at the RF-2 point of the joints at 5 mm, 20 mm, and 100 mm displacement. All connections reached the ultimate reaction force within the 20 mm to 40 mm range, as seen in Fig. 7. According to the results obtained from the figures, the maximum stress measured in the REF model was 9.32 MPa at 5 mm displacement, 16.45 MPa at 20 mm, and 27.19 MPa at 100 mm. As displacement increases, stress in the concrete elements increases. Stress was found to be concentrated in the lower part of the beam's column contact surface. At 5 mm and 20 mm displacements in the SP model, less stress occurred in the concrete. At 100 mm displacement, 33.01 MPa was measured. Stress was concentrated on the bottom surfaces of the beam and gusset. In the 2PG model, stresses were found to be higher than in the PG model at the three displacement steps. At displacements of 20 and 100 mm, the stresses in the concrete reached the ultimate strength. Therefore, crushing occurred under the beam and above the gusset. Additionally, the stress on the beam surface in contact with the plate was high. In the 2JP model, since the pins were only located within the gusset, the load of the pins was transferred directly to the gusset. Thus, high stress was measured in all three displacement stages according to the REF. In this model, the grout mortar stress capacity was exceeded at 100 mm displacement, and the mortar was crushed. In the PG, the single pin increased the stress. The low capacity of the joint was restricted by the pin tension capacity. Consequently, the stresses generated in the concrete elements were low. Stress intensity increased at the end and bottom of the gusset. The stress concentration created by the cleat angle and side bolt connected to the column in the PA was remarkable (Fig. 8). In this connection, the stress generated in the concrete elements was higher at all three displacement points compared to the REF connection. The stress capacity of the grout mortar was exceeded before reaching the 100 mm displacement point. Stress concentration was observed in the bottom parts of the beam and gusset. The stresses occurring in the connection elements and reinforcements at a 100 mm displacement are shown in Fig. 9. Table 2. Connection types and properties Definition Value Friction interface model Tangential behavior-Friction coefficient 0.8 Normal behavior/Allow separation after contact Hard contact Cold joint interface model Tangential behavior-Friction coefficient 0.8 Shear stress limit (MPa) 0.1 Normal behavior/Allow separation after contact Hard contact Table 3. Summary of the analysis results. Connection Type Ultimate vertical force, (kN) Difference between ultimate vertical force and reference force, (kN) Relative difference between ultimate vertical force and reference force, (%) REF 67 0.00 0.00 SP 95 +28.00 41.79 2JP 40 -27.00 -40.30 PG 33 -34.00 -50.75 2PG 46 -21.00 -31.34 PA 72 +5.00 7.46 Figure 7. Load-deflection graph of the models. F. Kıpçak Pamukkale University Journal of Engineering Sciences, XX(X), XXXX-XXXX, 20XX 8 Connection type 5 mm displacement 20 mm displacement 100 mm displacement REF SP 2JP PG 2PG PA Figure 8. Stress distributions observed at different displacement points at the beam end (RF-2). F. Kıpçak Pamukkale University Journal of Engineering Sciences, XX(X), XXXX-XXXX, 20XX 9 Stresses in the reinforcement at the REF are provided. The ultimate tension stress is 567 MPa after the yield strength of 420 MPa. In the REF model, the reinforcement at the top of the beam was observed to exceed its yield stressat a displacement of 5 mm. This stress was also observed to continue in the reinforcement extending from the beam into the column. The stress distribution formed on the cold joint contact surfaces in the SP model is given. It was observed that stress concentrations increased in the upper part of the gusset, reaching 23.10 MPa. The stress occurring in two J-type pins in the 2JP is given. At a displacement of 5 mm, a maximum stress of 446.88 MPa was observed in the part remaining in the grout mortar. Increased displacement caused the pins to rupture and collapse to occur. The stress in the plate and nuts can be said to have remained relatively low. At 5 mm displacement in the PG joint, the pin began to rupture. The stress limit in the plate and nut was not exceeded. Deformation occurred because of the pin rupturing. After the gusset, the stress in the pin is low in the section extending into the column. This shows that it can also be J-shaped. An increase in stress was observed at the point where the pin was first bent. However, this concentration was not observed in the section extending into the column. In the 2PG model, stress is concentrated at the top of the pins. In this model, stress is relatively low along the height of the grout compared to the PG model, but stress is high in the part extending into the column. The two pins that reached their ultimate strength failed at the same point at the top of the grout. No shearing or failure occurred on the plates or nuts. A maximum stress of 796.04 MPa was observed in the steel connecting elements in the PA. This stress was observed in the nuts. The stress in the pins is lower than the critical stress at 5 mm (567 MPa). Significant deformation was observed in the cleat angle. In this connection, the stress in the side bolt connecting the column was found to be quite high. Due to the collapse at the beam end, the cleat angle moved upward, and shear stress was effective in the side bolt. This situation has demonstrated that the simple additional connection was quite effective on the capacity. When the shear capacity of the side bolt was exceeded, the connection failed. The pin connecting to the gusset did not fail at the same time. With the increase in deflection at the beam end, the pin failed and the connection collapsed without any joints remaining. Although there was relatively low stress in the remaining section of the pin within the gusset, it was observed that the pin strengthened the connection between the column and the gusset. Figure 10 shows the displacement-compression and tension damage distributions of the models. The first vertical row shows the behavior at the beam end at 100 mm deflection. The compression and tension damage developments at the beam end at 5 mm deflection are shown in the second and third vertical row, respectively. In the figures, the concrete material is assumed to undergo crushing under compression and cracking under tension when the damage value exceeds 0.85. As shown in Fig. 10, significant tension damage occurred in the beam top and column connection areas before compression damage developed in the REF connection. At 100 mm displacement, significant rotation occurred in the connection, and the column was severely damaged. In the SP model, at 100 mm displacement, the beam fractured and displaced, while the column and gusset had less damage. Tension damage spread over a large area on the top of the beam. Transverse tension damage occurred at the top of the column. The 2JP model failed at 100 mm displacement due to the beam rotating and the pins breaking. At 5 mm displacement, there was no compression damage, but a row of transverse tension damage occurred at the top of the beam. The PG failed due to the rupture of a single pin. At 5 mm displacement, the compression damage did not exceed 0.85. However, tension damage occurred in the top part of the gusset. In this section, concrete damage was found to be low. In the 2PG model, similar to the PG model, failure occurred due to the rupture of the pins. The pins clearly ruptured above the gusset in the subsequent section of the analysis. The pins did not rupture at the height of the grout. The grout was completely damaged and became ineffective. When compression damage was examined, it was determined that there was no damage at the point of 5 mm displacement in the column and beam. In the case of tension damage, damage was evident on the gusset plate and on the beam near the plate. This type of damage was also observed in the 2JP model. In the PA, tension damage was concentrated in both the gusset and the beam. Tension damage was observed in the column section where the cleat angle was connected and in the upper part of the column. As the effectiveness of the steel elements in the connection increased, load transfer increased. Therefore, stresses and damage concentrations increased at lower displacements. IV. CONCLUSION Six different models were analyzed to investigate the behavior between precast beam-column connections in this study. These models were numerically investigated using Abaqus software. The elastic and plastic behaviors of the materials were considered, and load, displacement, deformation, and damage parameters of the connections were evaluated. The results showed that the type of connection directly affected the (a) (b) (c) (d) (e) (f) Figure 9. Stress distribution in connection elements at 100 mm displacement: (a) REF, (b) SP, (c) 2JP, (d) PG, (e) 2PG, (f) PA. F. Kıpçak Pamukkale University Journal of Engineering Sciences, XX(X), XXXX-XXXX, 20XX 10 Connection type Displacement at 100 mm in RF-2 (y-axis, mm) Compression damage ratio at 5 mm (%) Tension damage ratio at 5 mm (%) REF SP 2JP PG 2PG PA Figure 10. Displacement, compression and tension damage distributions. F. Kıpçak Pamukkale University Journal of Engineering Sciences, XX(X), XXXX-XXXX, 20XX 11 performance. Based on the results, the following conclusions were drawn. • The effectiveness of the gusset increased due to the short beam length. In the semi-prefabricated connection, the highest capacity was achieved due to the cold joint on the gusset and presence of gusset. The ultimate load of the monolithic connection was 67 kN, whereas the semi- prefabricated connection reached a load capacity of 95 kN. • The gusset efficiency was found to be effective in the connection with the added cleat angle element. In this connection, the capacity exceeded that of the reference model. • Only combinations using a single pin achieved the lowest capacity. Similar results were obtained with J-shaped pins or pins extending into the column. However, combinations with two pins were found to be relatively higher than those with a single pin. • The cleat angle connection capacity increased 2.18 times compared to a single-pin connection. Stress was found to be quite high in the side bolt. The connection failed first when the side bolt sheared, then when the pin ruptured. • As the number of steel elements increased, efficiency and load transfer increased. Simple but effective solutions were attained with cleat angle. • As the efficiency of the connection increased, stresses in the concrete elements increased and tension damage concentrated. • Using two J-pins increased the capacity by 1.21 times compared to using a single pin. • Extending two pins from the gusset to the column increased the capacity by 1.39 times compared to using a single pin, and by 1.15 times compared to using two J-pins. • The two pins extending from the gusset to the column contributed to the transfer of stress to the column, and the stress in the pins was distributed more uniformly. • In all models, the pins were ruptured from the top of the gusset. No bonding effect was observed in the pins.No shearing or rupture was observed in the plates or nuts. According to the results, pinned connections had a relatively low capacity when cleat angle was not used. In that case, it is recommended that designers use cleat angles and ensure the connection of the beam to the column with side bolts. As expected, there was no loss in the semi-prefabricated connection; on the contrary, the capacity increased. This was due to the use of gussets. The load transferred to the gusset was transferred to the column base through a shorter and inclined gusset structure. In this case, the gusset played a decisive role. Therefore, the use of gussets is recommended to mitigate the disadvantage associated with cold joints in semi-prefabricated connections. Contrary to single-pin connections, two-pin connections are recommended. A slight increase in capacity was observed, and rotational and out-of-plane displacement were partially restricted. Future studies may investigate extending the beam length. Connection behaviors for beams with large spans and located between two separate columns may be studied. In the future, the author plans to experimentally investigate some of these types of connections. AUTHOR STATEMENT Plagiarism Check—The article has been scanned with iThenticate and found to be compliant with the journal's plagiarism policy. Conflict of Interest—There is no conflict of interest with any person/organization. Ethics Committee Approval—Ethics committee approval is not required for this article. Use of Artificial Intelligence Tools—In this study, no artificial intelligence tools were used in article writing. All content reflects the original contribution of the author. Funding—No institutional/financial support was received for this study. Data availability—Permission is not granted to share the data. CRediT Author Contribution—Conceptualization, Methodology, Software, Validation, Formal analysis, Investigation, Resources, Data Curation, Writing – Original Draft, Writing – Review & Editing, Visualization, Supervision, Project Administration, Funding acquisition was all done by the sole author of the article. Acknowledgment—The author declares that no financial, technical, or institutional support was received for the conduct of this study. REFERENCES [1] M. F. Ishak, N. Hashim, “Precast Connection Behaviour Using Finite Element,” IOP Conference Series: Materials Science and Engineering, 849, 012084, 2020. https://doi.org/10.1088/1757-899X/849/1/ 012084. [2] H. M. Atalay, S. Ozden, “Cyclic Behavior of Beam-Column Connections in Precast Structures”, Frontiers in Built Environment, 7, 639778, 2021, https://doi.org/10.3389/fbuil.2021.639778. [3] Ş. M. Şenel, M. Palanci, A. Kalkan, Y. Yılmaz, “Mevcut Prefabrik Binaların Mafsallı Birleşimlerinin Kesme ve Devrilme Güvenliğinin Araştırılması”, Teknik Dergi, 24(119), 6505–6528, 2013, https:// izlik.org/JA36DS63CT. [4] F. Kıpçak, M. Tapan, B. Erdil, “Mafsallı pimli bağlantılarda deprem kaynaklı düzlem dışı göçme durumlarının araştırılması” Beton Prefabrikasyon, 39(155), 11–28, 2025, https://ebrosur.net/prefab/ [5] S. M. Senel, A. H. Kayhan, M. Palanci, A. Demir, “Assessment of Damages in Precast Industrial Buildings in the Aftermath of Pazarcık and Elbistan Earthquakes”, Journal of Earthquake Engineering, 29(16), 3337–3366, 2025. https://doi.org/10.1080/ 13632469.2024.2336206. [6] F. Avcil, E. Işık, R. İzol, A. Büyüksaraç, E. Arkan, M. H. Arslan, C. Aksoylu, O. Eyisüren, E. Harirchian, “Effects of the February 6, 2023, Kahramanmaraş earthquake on structures in Kahramanmaraş city”, Natural Hazards, 120(3), 2953–2991, 2024. https://doi.org/ 10.1007/s11069-023-06314-1. [7] E. Isik, M. R. Shendkar, F. Avcil, A. Büyüksaraç, S. S. Deshpande, “A Study on the Determination of Damage Levels in Reinforced Concrete Structures during the Kahramanmaras Earthquake on February 06, 2023”, E3S Web of Conferences - 2023 International Conference on Sustainable Technologies in Civil and Environmental Engineering, 405, 04029, 2023. https://doi.org/10.1051/e3sconf/ 202340504029. [8] Türkiye Cumhuriyeti Cumhurbaşkanlığı Strateji ve Bütçe Bakanlığı, “2023 Kahramanmaraş ve Hatay Depremleri Raporu”, 2023, Erişim adresi: https://www.sbb.gov.tr/wp-content/uploads/2023/03/ 2023-Kahramanmaras-ve-Hatay-Depremleri-Raporu.pdf. [9] S. C. Girgin, C. Göksoy, E. Daş, İ. S. Mısır, “Seismic performance evaluation of a precast concrete structure with deformation-based limit criterions”, Journal of Structural Engineering & Applied Mechanics, 4(3), 140–150, 2021, https://doi.org/10.31462/jseam. 2021.03140150. [10] B. Zoubek, T. Isakovic, Y. Fahjan, and M. Fischinger, “Cyclic Failure Analysis of the Beam-to-Column Dowel Connections in Precast Industrial Buildings,” Engineering Structure., 52, 179–191, 2013. https://doi.org/10.1016/j.engstruct.2013.02.028. [11] Joint Research Centre: Institute for the Protection and Security of the Citizen, “Design Guidelines for Connections of Precast Structures under Seismic Actions”, P. Negro, G. Toniolo, Eds., Publications Office of the European Union, Luxembourg, 2012. https://doi.org/10.2777/37605. [12] C. Aksoylu, Y. O. Özkılıç, Ş. Yazman, L. Gemi, M. Arslan, “İnceltilmiş Uçlu Önüretimli Aşık Kirişlerinin Yük Taşıma Kapasitelerinin Deneysel ve Numerik Olarak İrdelenmesi ve Çözüm Önerileri”, Teknik Dergi, 32(3), 10823–10858, 2021. https://doi.org/ 10.18400/tekderg.667066. [13] G. Magliulo, C. Di Salvatore, M. Ercolino, “Modeling of the Beam-To- Column Dowel Connection for a Single-Story RC Precast Building”, Frontiers in Built Environment, 7, 627546, 2021, https://doi.org/ 10.3389/fbuil.2021.627546. [14] G. D. Kremmyda, Y. M. Fahjan, I. N. Psycharis, S. G. Tsoukantas, “Numerical Investigation of the Resistance of Precast RC Pinned Beam-to-Column Connections Under Shear Loading”, Earthquake Engineering & Structural Dynamics., 46(9), 1511–1529, 2017, https://doi.org/10.1002/EQE.2868. [15] A. Saviotti, P. Olmati, F. Bontempi, “Finite Element Analysis of Innovative Solutions of Precast Concrete Beam-Column Ductile Connections”, Bridge Maintenance, Safety, Management, Resilience and Sustainability - Proceedings of the Sixth International Conference on Bridge Maintenance, Safety and Management, 2048–2055, 2012. https://doi.org/10.1088/1757-899X/849/1/012084 https://doi.org/10.1088/1757-899X/849/1/012084 https://doi.org/10.3389/fbuil.2021.639778 https://ebrosur.net/prefab/ https://doi.org/10.1080/13632469.2024.2336206 https://doi.org/10.1080/13632469.2024.2336206 https://doi.org/10.1007/s11069-023-06314-1 https://doi.org/10.1007/s11069-023-06314-1 https://doi.org/10.1051/e3sconf/%0b202340504029 https://doi.org/10.1051/e3sconf/%0b202340504029 https://www.sbb.gov.tr/wp-content/uploads/2023/03/%0b2023-Kahramanmaras-ve-Hatay-Depremleri-Raporu.pdf https://www.sbb.gov.tr/wp-content/uploads/2023/03/%0b2023-Kahramanmaras-ve-Hatay-Depremleri-Raporu.pdf https://doi.org/10.31462/jseam.%0b2021.03140150 https://doi.org/10.31462/jseam.%0b2021.03140150 https://doi.org/10.1016/j.engstruct.2013.02.028 https://doi.org/10.2777/37605 https://doi.org/10.18400/tekderg.667066 https://doi.org/10.18400/tekderg.667066 https://doi.org/10.3389/fbuil.2021.627546 https://doi.org/10.3389/fbuil.2021.627546 https://doi.org/10.1002/EQE.2868 F. Kıpçak Pamukkale University Journal of Engineering Sciences, XX(X), XXXX-XXXX, 20XX 12 [16] H. Balineni, D. C. K. Jagarapu, A. Eluru, “Analysis of Dry and Wet Connections in Precast Beam-Column Joint Using ABAQUS Software”, Materials Today–Proceedings, 33, 287–295, 2020. https://doi.org/10.1016/j.matpr.2020.04.073. [17] B. P. V. N. Sai, D. C. K. Agarapu, A. Eluru, “Assay of Moment-Resisting Precast and Monolithic Frames Using ABAQUS Software”, Materials Today–Proceedings, 33, 162–169, 2020. https://doi.org/10.1016/ j.matpr.2020.03.735. [18] P. R. Kalyana Chakravarthy, R. Janani, T. Ilango, “Analysing the Strength Aspectsof Precast Reinforced Beam-Column Connections”, International Journal of Mechanical Engineering and Technology, 9(13), 118–133, 2018, [Online]. Available: http://iaeme.com/Home/issue/IJMET?Volume=9&Issue=13. [19] S. Shukri, N.Taib, N. M. Husain, M. Taib. “Finite Element Analysis On Beam To Column Connection In Ibs Panel”, Carving The Future Built Environment: Environmental, Economic And Social Resilience, vol 2. European Proceedings of Multidisciplinary Sciences, P. A. J. Wahid, P. I. D. A. Aziz Abdul Samad, P. D. S. Sheikh Ahmad, A. P. D. P. Pujinda, Eds., Future Academy, 2017, 447-458. https://doi.org/ 10.15405/epms.2019.12.43. [20] F. Kıpçak, “Numerical Study of the Out-of-Plane Response of Dry- Stack Double-Wythe Brick Walls with Header Bricks”, Buildings, 15(23), 4342, 2025, https://doi.org/10.3390/buildings15234342. [21] F. Kıpçak, B. Erdil, “Effect of Adobe Wall Shapes and Openings on Out-of-Plane Behavior”, Structures, 77, 109090, 2025, https://doi.org/10.1016/j.istruc.2025.109090. [22] F. Kıpçak, B. Erdil, “Yığma yapıların düzlem dışı davranışlarına yan duvarın ve yan duvar boşluğunun etkisi”, Niğde Ömer Halisdemir Üniversitesi Mühendislik Bilimleri Dergisi, 12(3), 853–860, 2023. https://doi.org/10.28948/ngumuh.1268912. [23] F. Kıpçak, B. Erdil, M. Tapan, A. Karaşin, “The Effect of Voids on Flexural Capacity of Reinforced Concrete Slabs”, Periodica Polytechnica–Civil Engineering, 67(4), 1048–1065, 2023, https://doi.org/10.3311/PPci.21988. [24] B. Zoubek, M. Fischinger, T. Isakovic, “Estimation of the Cyclic Capacity of Beam-to-Column Dowel Connections in Precast Industrial Buildings”, Bulletin of Earthquake Engineering, 13(7), 2145–2168, 2015. https://doi.org/10.1007/s10518-014-9711-0. [25] S. Kallam, S. B. Borghate, “Nonlinear Numerical Evaluation of Dry Precast Beam Column Connection with Embedded Bolts”, Latin American Journal of Solids and Structures, 19(7), e464, 2022. https://doi.org/10.1590/1679-78257314. [26] G. D. Kremmyda, Y. M. Fahjan, S. G. Tsoukantas, “Nonlinear FE Analysis of Precast RC Pinned Beam-to-Column Connections Under Monotonic and Cyclic Shear Loading”, Bulletin of Earthquake Engineering, 12(4), 1615–1638, 2014, https://doi.org/10.1007/ s10518-013-9560-2. [27] Simulia, ABAQUS 6.14 user’s manuals. Dassault Systems Simulia Corporation, 2016, http://130.149.89.49:2080/v2016/pdf_books/ ANALYSIS_2.pdf . [28] A. S. Genikomsou, M. A. Polak, “Finite Element Analysis of Punching Shear of Concrete Slabs Using Damaged Plasticity Model in ABAQUS”, Engineering Structures, 98, 38–48, 2015, https://doi.org/ 10.1016/j.engstruct.2015.04.016. [29] I. Rewers, “Numerical Analysis of RC beam with High Strength Steel Reinforcement using CDP model”, IOP Conference Series: Materials Science and Engineering, 471, 022025, 2019. https://doi.org/ 10.1088/1757-899X/471/2/022025. [30] T.C. Çevre Şehircilik ve İklim Değişikliği Bakanlığı, “Riskli Yapıların Tespit Edilmesine İlişkin Esaslar”, 2023, https://webdosya. csb.gov.tr/db/altyapi/icerikler/r-skl--yapilarin-tesp-t-ed-lmes-ne- il-sk-n-esaslar-20190218134628.pdf. [31] Betonarme Yapıların Tasarım ve Yapım Kuralları (Requirements for Design and Construction of Reinforced Concrete Structures), TS 500/2000, Ankara, Turkey, 2000, https://www.resmigazete.gov. tr/eskiler/2000/07/20000712M1-23.pdf. [32] Code for Design of Concrete Structures, Chinese Code-GB50010, Chinese: National Standard of the People’s Republic of China, 2010, https://www.chinesestandard.net/PDF/English.aspx/GB50010- 2015. [33] Y. Guo, G. Gong, C. Chin, C. Zhang, “Structural Design of Concrete to EC2 and GB50010-2010: A Comparison”, MATEC Web of Conferences–2018 International Forum on Construction, Aviation and Environmental Engineering-Internet of Things (IFCAE-IOT 2018), 175, 01039, 2018. https://doi.org/10.1051/matecconf/ 201817501039. [34] G. Kaklauskas, V. Gribniak, P. L. Ng, E. Gudonis, R. Jakubovskis, “Generalised tension-stiffening relationship conforming to Chinese Design Code GB 50010-2010”, International Conference on Performance-based and Life-cycle Structural Engineering, Brisbane, QLD, Australia, 9-11 December 2015, 630–639. https://doi.org/ 10.14264/UQL.2016.1180. [35] L. Guo, R. Mao, Z. Liu, S. Li, G. Wu, Z. Wang, “Dynamic Large Deflection Response of RC Beams under Low-Speed Impact Loading”, Shock and Vibration, 2020, 8812890, 2020. https://doi.org/10.1155/2020/8812890. [36] Çelik-Betonarme İçin Donatı Çeliği (Steel for the Reinforcement of Concrete - Reinforcing Steel), TS 708, Ankara, Turkey, 2010. https://regbar.com/wp-content/uploads/2019/09/TS_708- 2010.pdf” [37] Eurocode 3: Design of steel structures – Part 1-1: General rules and rules for buildings, EN 1993-1-1, European Committee for Standardization [CEN], 2005, https://www.phd.eng.br/wp-content /uploads/2015/12/en.1993.1.1.2005.pdf [38] X. Yun, L. Gardner, “Stress-Strain Curves for Hot-Rolled Steels”, Journal of Constructional Steel Research, 133, 36–46, 2017. https://doi.org/10.1016/j.jcsr.2017.01.024. [39] A. S. Daryan, H. Ketabdari, “Mechanical Properties of Steel Bolts with Different Diameters after Exposure to High Temperatures”, Journal of Materials in Civil Engineering, 31(10), 04019221, 2019. https://doi.org/10.1061/(asce)mt.1943-5533.0002865. [40] Çelik Yapıların Tasarım, Hesap ve Yapım Esaslarına Dair Yönetmelik. Resmi Gazete (Sayı: 29614), Yayın Tarihi (04/02/2016), https://www.resmigazete.gov.tr/eskiler/2018/02 /20180215M1-4-1.pdf. [41] Türkiye Bina Deprem Yönetmeliği, Resmi Gazete (Sayı:30364), Yayın Tarihi: 18.03.2018, https://www.resmigazete.gov.tr/ eskiler/2018/03/20180318M1-2-1.pdf. [42] S. M. Senel, M. Palanci, “Structural Aspects and Seismic Performance of 1-Story Precast Buildings in Turkey”, Journal of Performance of Constructed Facilities, 27(4), 437–449, 2013. https://doi.org/ 10.1061/(ASCE)CF.1943-5509.0000316. https://doi.org/10.1016/j.matpr.2020.04.073 https://doi.org/10.1016/j.matpr.2020.03.735 https://doi.org/10.1016/j.matpr.2020.03.735 http://iaeme.com/Home/issue/IJMET?Volume=9&Issue=13 https://doi.org/10.15405/epms.2019.12.43 https://doi.org/10.15405/epms.2019.12.43 https://doi.org/10.3390/buildings15234342 https://doi.org/10.1016/j.istruc.2025.109090 https://doi.org/10.28948/ngumuh.1268912 https://doi.org/10.3311/PPci.21988 https://doi.org/10.1007/s10518-014-9711-0 https://doi.org/10.1590/1679-78257314 https://doi.org/10.1007/s10518-013-9560-2 https://doi.org/10.1007/s10518-013-9560-2 http://130.149.89.49:2080/v2016/pdf_books/ANALYSIS_2.pdf http://130.149.89.49:2080/v2016/pdf_books/ANALYSIS_2.pdf https://doi.org/10.1016/j.engstruct.2015.04.016 https://doi.org/10.1016/j.engstruct.2015.04.016 https://doi.org/10.1088/1757-899X/471/2/022025 https://doi.org/10.1088/1757-899X/471/2/022025 https://webdosya.csb.gov.tr/db/altyapi/icerikler/r-skl--yapilarin-tesp-t-ed-lmes-ne-il-sk-n-esaslar-20190218134628.pdf https://webdosya.csb.gov.tr/db/altyapi/icerikler/r-skl--yapilarin-tesp-t-ed-lmes-ne-il-sk-n-esaslar-20190218134628.pdf https://webdosya.csb.gov.tr/db/altyapi/icerikler/r-skl--yapilarin-tesp-t-ed-lmes-ne-il-sk-n-esaslar-20190218134628.pdf https://www.resmigazete.gov.tr/eskiler/2000/07/20000712M1-23.pdf https://www.resmigazete.gov.tr/eskiler/2000/07/20000712M1-23.pdf https://www.chinesestandard.net/PDF/English.aspx/GB50010-2015 https://www.chinesestandard.net/PDF/English.aspx/GB50010-2015 https://doi.org/10.1051/matecconf/201817501039 https://doi.org/10.1051/matecconf/201817501039 https://doi.org/10.14264/UQL.2016.1180 https://doi.org/10.14264/UQL.2016.1180 https://doi.org/10.1155/2020/8812890 https://regbar.com/wp-content/uploads/2019/09/TS_708-2010.pdf https://regbar.com/wp-content/uploads/2019/09/TS_708-2010.pdf https://www.phd.eng.br/wp-content/uploads/2015/12/en.1993.1.1.2005.pdf https://www.phd.eng.br/wp-content/uploads/2015/12/en.1993.1.1.2005.pdf https://doi.org/10.1016/j.jcsr.2017.01.024 https://doi.org/10.1061/(asce)mt.1943-5533.0002865https://www.resmigazete.gov.tr/eskiler/2018/02/20180215M1-4-1.pdf https://www.resmigazete.gov.tr/eskiler/2018/02/20180215M1-4-1.pdf https://www.resmigazete.gov.tr/%0beskiler/2018/03/20180318M1-2-1.pdf https://www.resmigazete.gov.tr/%0beskiler/2018/03/20180318M1-2-1.pdf https://doi.org/10.1061/(ASCE)CF.1943-5509.0000316 https://doi.org/10.1061/(ASCE)CF.1943-5509.0000316