Björn Engström
Division of Structural Engineering
Design of 
Structural 
Connections
Björn Engström
Chalmers University of Technology
Göteborg, Sweden
Björn Engström
Division of Structural Engineering
Content
• Design philosophy
– Structural purpose
– Force paths at different levels
– Mechanical behaviour – design aspects
• Basic force transfer mechanisms
– Compression
– Shear 
– Tension
– Bending - torsion
• fib Bulletin on –Structural connections
Björn Engström
Division of Structural Engineering
Design of structural connections
Design aspects:
Björn Engström
Division of Structural Engineering
Structural behaviour for ordinary 
and excessive loads
Björn Engström
Division of Structural Engineering
Appearance and function in the 
service state
Björn Engström
Division of Structural Engineering
Structural fire protection
• Load bearing function
• Separating function
Björn Engström
Division of Structural Engineering
Manufacture
• Production of precast elements
• Handling, storage and transportation of 
precast elements
Björn Engström
Division of Structural Engineering
Mounting of precast systems 
Mounting should be possible
Accessibility
Tolerances
Björn Engström
Division of Structural Engineering
Modular co-ordination
Traditional detail Alternative detail
Björn Engström
Division of Structural Engineering
Demountability
Björn Engström
Division of Structural Engineering
Force paths – structural level
Björn Engström
Division of Structural Engineering
Force paths – structural level
Fixed end
columns
Diaphragm action
Shear panels
Björn Engström
Division of Structural Engineering
Force paths –structural level
Compression
Tension
Tension
Compression
Core
Shear walls
Floor diaphragms
Shear 
Shear
Compression
Tension
Compression
Core
Tension
Shear walls
Floor diaphragms
Shear
Shear
Björn Engström
Division of Structural Engineering
Force paths –
structural subsystems 
In-plane action of precast floor
Björn Engström
Division of Structural Engineering
Force paths –
structural subsystems
In-plane action of precast wall
Björn Engström
Division of Structural Engineering
The force paths – local level
Björn Engström
Division of Structural Engineering
Alternative designs – force paths
Björn Engström
Division of Structural Engineering
Alternative 
designs –
force paths
Björn Engström
Division of Structural Engineering
Design of the whole connection
The connection as part of the structural 
system
Björn Engström
Division of Structural Engineering
Design and detailing
for safe force paths
Björn Engström
Division of Structural Engineering
Flow of forces 
through the 
connection and 
further away
Björn Engström
Division of Structural Engineering
Mechanical behaviour
Björn Engström
Division of Structural Engineering
Mechanical response
Björn Engström
Division of Structural Engineering
Need for movement
Björn Engström
Division of Structural Engineering
Balanced design for ductility
Björn Engström
Division of Structural Engineering
Anchorage for ductility
Avoid anchorage failures
Provide anchorage for rupture of the steel
Björn Engström
Division of Structural Engineering
Unintended restraint
Björn Engström
Division of Structural Engineering
Avoid unfavourable crack locations
Unfavourable
Preferred
Björn Engström
Division of Structural Engineering
Alternative solutions
Björn Engström
Division of Structural Engineering
Unintended composite action
Björn Engström
Division of Structural Engineering
Force transfer in connections
Björn Engström
Division of Structural Engineering
Basic force transfer mechanisms
 
w 
NN 
Compression
Tension
Shear
Björn Engström
Division of Structural Engineering
Transfer of compression
local compression,
compressive strength
in confined concrete
stress dispersion
splitting effects
tension
Björn Engström
Division of Structural Engineering
Compression through several layers
Björn Engström
Division of Structural Engineering
Design of bearings
Björn Engström
Division of Structural Engineering
Design of soft bearings
Consider vertical resistance
Limit shear deformation for horizontal loads
Compression over the entire face of the bearing pad
Avoid direct contact in case of rotation
Avoid that the bearing protrudes outside the edges
Björn Engström
Division of Structural Engineering
Design examples
Wall connection 
with mortar joint Beam support 
with soft bearing
Björn Engström
Division of Structural Engineering
Design examples
Beam column connection
with steel plates
Hollow core floor wall connection
Björn Engström
Division of Structural Engineering
Bolted connections
Björn Engström
Division of Structural Engineering
Failure modes of bolted 
connection
Shear failure of bolt
Splitting of concrete
Combined bending 
in bolt and crushing of 
concrete
Björn Engström
Division of Structural Engineering
Avoid splitting failure
 
 
 
Q 
Björn Engström
Division of Structural Engineering
Design of splitting reinforcement
 
 
 
Compare with local 
compression
Björn Engström
Division of Structural Engineering
Dowel action – one-sided
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 syccR ffV ⋅φ= 2
 
 
φ⋅
=
cc
R
f
Vx
30
 
Failure 
mechanism 
High 
compression
High 
bending 
stress
Q Q
x0
Bending failure in bolt
crushing of concrete
Björn Engström
Division of Structural Engineering
Effect of eccentricity
1
0.18322
k e1 e( )
k e2 e( )
2.50 ζ
0 0.5 1 1.5 2 2.5
0
0.2
0.4
0.6
0.8
1
eccentricity factor ke
1
0,8
0.6
0,4
0,2
0 0 0,5 1,0 1,5 2,0 2,5
e/φ
 
 
 sycceR ffkV ⋅φ= 2 
 
 
φ⋅
=
cc
R
f
Vx
30 
 
Q 
x0
e 
20/500
50/320
fck/fyk
Björn Engström
Division of Structural Engineering
Dowel action – two-sided
Slip
Slip
 
 syccR ffV ⋅φ= 2 
 
φ⋅
=
cc
R
f
Vx
30 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
x0
x0
2e
fcc
fcc
Björn Engström
Division of Structural Engineering
Different conditions
Failure 
mechanism
 
 symincc ffV ⋅φ= ,
2
1 
 
φ⋅
=
mincc
R
f
Vx
.
, 310 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
x0,1
2e
fcc,max
fcc,min 
 
 symincc ffV ⋅φ= ,
2
1 
 
φ⋅
=
mincc
R
f
Vx
.
, 310 
 
 
 
 
 
 
 
 
 
 
 
symaxccR ffV ⋅φ= ,
2 
 
φ⋅
=
max,
,
cc
R
f
Vx
320 
x0,2 
x0,1
2e 
fcc,max
fcc,min
Björn Engström
Division of Structural Engineering
Response in shear
 
 
Shear slip 
Shear force 
First plastic hinge
Second plastic hinge ⇒ plastic mechanism 
 
 symincc ffV ⋅φ= ,
2
1 
 
φ⋅
=
mincc
R
f
Vx
.
, 310 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
x0,1
2e 
fcc,max
fcc,min
Björn Engström
Division of Structural Engineering
Effect of restraint 
 
 
syccrR ffkV ⋅φ⋅= 2 
 
φ⋅
=
cc
R
f
Vx
30 
 
 21 ≤≤ rk 
 
 
 
 
 
 
 
 
 
 
 
fcc
fcc
My,red 
x0
Björn Engström
Division of Structural Engineering
Restraint and eccentricity
 
 syccreR ffkV ⋅φ⋅= 2
, 
 
φ⋅
=
cc
R
f
Vx
30 
 
ε−ε+= 22
rre kk , 
 
 
 
 
 
 
 
 
 
 
 
 
 
fcc
x0 
e 
fcc
Björn Engström
Division of Structural Engineering
Effect of anchorage
 
 
 
 redsccssR ffAV ,)( ⋅φ+σ⋅µ= 2 
 
ssredr ff σ−=, 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
fcc
x0 
x0 
fcc
Björn Engström
Division of Structural Engineering
What happened here?
I II III
Björn Engström
Division of Structural Engineering
Shear in joints
Björn Engström
Division of Structural Engineering
Shear friction
Shear slip
Crack
width
Crack width
Shear slip
Björn Engström
Division of Structural Engineering
Self-generated friction
Björn Engström
Division of Structural Engineering
Influence of bond and anchorage
 
s
w Fv
Fv
deformed bars
strain localisation
high steel stress
yields for 
small slip,
friction dominates
Björn Engström
Division of Structural Engineering
Influence of bond and anchorage
shearslip
joint separation
induced
tension
plain bars
uniform strain
low steel stress
 
s
w Fv
Fv
yields for 
large slip,
friction + dowel
Björn Engström
Division of Structural Engineering
Compare with bolted connection
 
 
 redsccssR ffAV ,)( ⋅φ+σ⋅µ= 2 
 
ssredr ff σ−=, 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
fcc
x0
x0
fcc
 
s
w Fv
Fv 
Shear friction in joint
Plain bars with end anchors
Bolted connection
Plain bolt with end anchors
Björn Engström
Division of Structural Engineering
Different responses
External bars Internal reinforcement
Björn Engström
Division of Structural Engineering
When will the transverse bars yield?
 
s
w Fv
Fv 
Depends on:
joint roughness
bond resistance of 
transverse bar
Björn Engström
Division of Structural Engineering
Maximum crack width vs. 
end slip response of transverse bar
Maximum crack width
Bar yields in shear 
friction
Force in bar Force in bar
Maximum crack width
Bar yields not in shear friction
Force in bar
Crack width Crack width
Björn Engström
Division of Structural Engineering
Increased joint separation
 
52
6
Joint profile with wave-
shaped undulations
Björn Engström
Division of Structural Engineering
Joints with shear keys
with shear keys
plain joints
shear stress
slip
Björn Engström
Division of Structural Engineering
Shear transfer – clamping is needed
Björn Engström
Division of Structural Engineering
Distributed ties provides clamping
Björn Engström
Division of Structural Engineering
Concentrated ties provide clamping
Adequate between elements with high in-plane 
stiffness that are arranged in the same plane
Björn Engström
Division of Structural Engineering
Distributed ties are needed here
Inclined forces separate
the elements arranged 
at a corner Example of distributed ties
between floor and wall
Björn Engström
Division of Structural Engineering
Shear resistance of joints depends 
on overall design of the subsystem
Björn Engström
Division of Structural Engineering
Design examples
Frictional resistance of concrete
interface
 
High 
compression High 
bending 
stress 
Fv
Response of plain dowel
Björn Engström
Division of Structural Engineering
Connections between wall 
elements
monolithic
with shear keys
plain
monolithic plain with 
shear-keys
Björn Engström
Division of Structural Engineering
Connections between floor 
elements
Uncracked joint
Cracked joints
Vertical shear
capacity
Björn Engström
Division of Structural Engineering
Applications
longitudinal tie 
transversal ties 
transversal ties
reinforcement 
in concrete 
filled sleeves 
joint fill 
cast in-situ 
concrete 
Shear transfer in hollow
core floor
 
1 
beff 
2 
3 
4 
6 7 
5 
Shear transfer in composite
beams
 
2 3 4 
beff 
1 
Björn Engström
Division of Structural Engineering
Transfer of tension
 
l ty l t,pl
suF plτ 
yτ 
2 φ
 
Anchorage with bond
Anchor head
Björn Engström
Division of Structural Engineering
Headed bar
Concrete capacity
design approach
Björn Engström
Division of Structural Engineering
Design of connection zone
The force must go further
Local compression Anchorage of headed bar
Björn Engström
Division of Structural Engineering
Hollow core floor connection 
Tensile capacity is
needed for:
diaphragm action 
in floor
shear friction 
resistance of joints
Björn Engström
Division of Structural Engineering
Bond stress development
Björn Engström
Division of Structural Engineering
Bond stress development
Björn Engström
Division of Structural Engineering
Inclined bond forces
α
α
 
α 
b τ 
tanα bτ .
N
Björn Engström
Division of Structural Engineering
Splitting cracks
Björn Engström
Division of Structural Engineering
Anchorage failures
N Nmax
N N max 
Splitting
Pull-out
Björn Engström
Division of Structural Engineering
Tensile force development
Influence of embedment length
0
20
40
60
80
100
120
140
0 100 200 300 400 500
Position x [mm]
Tensile force
[kN]
N220
N290a
N500
H90b
H170
H210
H250
Tensile capacity
Yield capacity
Björn Engström
Division of Structural Engineering
Bond stress - slip relation
.
.
.
.
.
.
.
..
.
.
.
. .
.
. . . . .
.
..
.
Slip
Force
Bond, τb40 
mm
.
.
.
.
.
.
.
..
.
.
.
. .
.
. . . . .
.
..
.
Slip
Force
Bond, τb40 
mm
0
5
10
15
20
25
30
35
40
45
50
0 5 10 15 20 25 30
Passive end-slip [mm]
Bond stress 
[MPa]
HSC
NSC
Björn Engström
Division of Structural Engineering
End slip
 
Slip 
Steel bar in tension Steel bar 
Reference point 
 F 
Björn Engström
Division of Structural Engineering
Elastic response
1.58184
0
w 6 σ s
w 8 σ s
w 10 σ s
w 16 σ s
w 20 σ s
w 25 σ s
w 32 σ s
5 108.0 σ s
0 1 108 2 108 3 108 4 108 5 108
0
0.5
1
1.5
2
Steel stress [MPa]
Crack width [mm]
0 100 200 300 400 500
2,0
1,5
1,0
0,5
0
φ32
φ25
φ20
φ16
φ12
φ10
φ8
φ6
Björn Engström
Division of Structural Engineering
Yield penetration
 
lty lt,pl 
Fsu
τpl 
2φ 
τy
Plastic zone
Elastic zone
Björn Engström
Division of Structural Engineering
Response of connections
 
w 
NN 
 N 
F su 
w y
F sy 
w u w w u0,5 
Rupture
of bar
Björn Engström
Division of Structural Engineering
This information was needed
 
s
w Fv
Fv 
Depends on:
joint roughness
bond resistance of 
transverse bar
When will the 
transverse bars 
yield?
Björn Engström
Division of Structural Engineering
Maximum crack width vs. 
end slip response of transverse bar
Maximum crack width
Bar yields in shear 
friction
Force in bar Force in bar
Maximum crack width
Bar yields not in shear friction
Force in bar
Crack width Crack width
Björn Engström
Division of Structural Engineering
Examples
 
101
109
N [kN]
send [mm]
send,y = 
0,468 
0,5send,u =
0,795 
send,u = 
1,59 
Prediction of end-slip
response of anchor bar
Björn Engström
Division of Structural Engineering
Examples
Design of anchorage allowing
for full yield penetration
Effect of local weakening
Björn Engström
Division of Structural Engineering
Examples
 
w 
N N 
Estimation of tie bar stiffness
Design of loop 
connection
Björn Engström
Division of Structural Engineering
Prevention of progressive 
collapse
• Withstand accidental 
loading
• Reducing the risk of 
accidental loading
• Increase redundancy and 
prevent propagation of 
initial damage
Björn Engström
Division of Structural Engineering
Analysis of collapse mechanisms
l
A B
d
Q
[ m ]
6,0
4,5
 
5,0 5,0
3,0
3,0
3,0
 N
F su 
w y
F sy 
w u w w u 0,5
Tie force
Crack width
Björn Engström
Division of Structural Engineering
Transfer of bending moment
Beam column
connections
Björn Engström
Division of Structural Engineering
Transfer of bending moment
Column splice
connection
Column base
connections
Björn Engström
Division of Structural Engineering
Transfer of bending moment
Floor connections: 
no restraint, unintended restraint, full restraint, partial 
continuity in the service state
Björn Engström
Division of Structural Engineering
Example
60
100
30
Thin plastic
sheet
2 rebars d=12
 L = 5300
Rebars d 10 
c/c 300, 
L = 200+300
200
100
70Plywood board
30x50x60
under webs,
2 pc./slab end
100
50
40
100
Fs
w
d
ϕ
Moment – rotation response of connection at end support
Björn Engström
Division of Structural Engineering
Transfer of torsional moment
Simply supported Firmly connected
Torsional restraint
at beam support
 
 q 
Björn Engström
Division of Structural Engineering
fib Bulletin on 
Structural Connections
• Encourage good practice in design of 
structural connections
• Design philosophy
• Connections ⇔ Structural system
• Understanding of basic force transfer 
mechanisms

Mais conteúdos dessa disciplina