Commissioning & Standard Programming 
with CCT : Learner Guide 
10236DV001 
Our Policy prohibits printing. Save GREEN. 1
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
How to use your Learning Guide 
Your Learning Guide is intended to facilitate your participation and learning both during the course and after your finish the 
facilitated three day session. 
During the Facilitated Session: 
During the session you might want to consider having two monitors available. On the one monitor you can view the 
WebEx presentation and on the other you can have your Learning Guide open to quickly access Lab Activities, review 
previously delivered slides while working with hands-on activities, or use online links to quickly download videos or other 
resources. 
You will notice that your Learning Guide has a “home icon” (see image below) on the top of each page. Clicking on the 
icon will return you to the Table of Contents so you can easily navigate to specific sections of your Guide. 
2
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
After the Facilitated Session: 
After you have completed the facilitated three-day session, you may continue to use your Learning Guide to review 
pertinent materials while on the job. Optionally, you may decide to watch a video to refresh your memory regarding 
specific processes. Finally, you may want to simply remind yourself of resources available to you for performing 
necessary tasks. 
3
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Getting Ready: What to Do Before the Course 
You will be participating in this course using a WebEx connection so it can be taken from your office or home location 
so it can be taken from your office or home location; just make sure you have a good Internet network connection and 
phone connection. There are steps, however, that you need to complete to ensure an optimal experience. These 
include: (1) ensuring you have good computer and phone connections; (2) making sure that you have the proper 
equipment; and (3) downloading all course materials. 
Ensuring Your Computer and Phone Connections: 
Please connect on the Phone Conference and WebEx, at least 15 minutes before the start time, to ensure proper 
connections before the course begins. 
Telephone Number for the phone conference: 
1-414-214-4100
Internet Browser Address for the WebEx website: 
Jci.Webex.Com (Note that there is no www or http:// in front of jci.webex.com) 
Look for the Class called “10236: CCT Class” 
Select Join, and then enter your name, email and your WebEx Password 
 Note: You will receive an email from your instructor about a week before the class with the webex and 
 telephone conference passwords. 
4
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Note: If Join is not immediately available, wait a few minutes, then refresh the web page and look for Join 
again. 
Meeting the Computer Requirements: 
Your computer must have current release of CCT which is Version 10.1 or greater installed. Your CCT Version 
number can be found by selecting CCT’s Help menu and then select Tool About. 
Remember, as part of the class you will need an FEC or FAC, a VMA, a BTCVT and a Netsensor is recommended. 
That was a prerequisite you also needed in the precourse which you have already completed. 
Downloading Course Materials: 
Prior to the start of the course go to the BE Class Support Center at: 
https://my.jci.com/sites/BESalesOpsLearn/Pages/Homepage.aspx Scroll down and navigate to the C-10236 link 
Download the Course Learner Guide, the CAFs for the course and the videos. (Basically, everything under that C- 10236 
directory) 
You probably want to store these on the hard drive in a directory since you may want to refer to them in the future, so 
in your my documents directory (or another place you have chosen) make a directory called 10236 and store all 
these downloads there) 
Remember that the class will start at 8:00 AM Central time and conclude at 5:00 PM Central time each 
day [Make sure you recalculate the start time for “your” local time zone.]
5
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Commissioning & Standard 
Programming with CCT 
A Single Controller 
6
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Throughout the Course you will see Some or all of These Icons Which are Used to Represent Types of 
Activities, Actions, Resources, Media Inserts or Other Features. 
Understanding Course Icons 
Activity Resources Video 
Tools Scenario Ask an Expert 
7
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Accessing Handouts and Support Materials 
Scroll down and click on the 
C-10236 folder.
Go to the BE Class Support Center at 
https://my.jci.com/sites/BESalesOpsLearn/CrSp/SitePages/Home.aspx 
8
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Using your WebEx Annotation Tools 
Pointer Type 
Text 
Draw 
Lines or 
Shapes 
Pen Select 
Color 
Clear 
Annotations 
9
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Prior to participating in this course today you completed the 
e-learning course: “Introduction to the Controller Configuration
Tool” and passed the associated skills and knowledge 
assessment. 
10
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
CCT Basics: Online Learning Summary 
 (Key points) 
As you may recall from “Introduction to the Controller Configuration Tool”: 
 There is a family of Metasys® Equipment Controllers that operate with
Network Automation Engines (NAEs).
 The Programming Tool is software used with the programmable MS/TP or
N2 controllers which has three operating modes.
 By using Show Involvement you can associate outputs with the modules
controlling them.
 You can identify where Bluetooth® is or can be
used, define the port and set up serial linkage
to a Bluetooth® device.
11
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. Our Policy prohibits printing. Save GREEN. 
Uploading and 
Downloading a Single 
Controller 
Troubleshooting 
Software 
Connections 
Lab: Downloading 
and Uploading a 
Single Controller 
Uploading and 
Downloading Multiple 
Controllers 
 Lab: 
Commissioning an 
FCU 
 Lab: VAV Box Flow 
Test 
Modifying Inputs 
and Outputs 
Commissioning 
Programs 
Lab: Commissioning 
a VAV 
Lab: Input and Output 
Commissioning 
Day 1 Day 2 Day 3Labs Resources Lessons 
Resources 
Lab: Downloading 
and Uploading 
Multiple Controllers 
12
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. Our Policy prohibits printing. Save GREEN. 
Lab: Application 
Creation 
Peer to Peer Application 
Creation 
Sideloop 
 Lab: Data Flow in 
CCT Programs 
Lab: Making 
Alterations to 
Programs in CCT 
State Tables Data Flow and 
Saturation Timers 
Day 1 Day 2 Day 3 Resources 
Labs Resources Lessons 
13
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. Our Policy prohibits printing. Save GREEN. 
Logic Blocks MUX Lab: Logic Module and 
Block Analysis 
Timers 
 Lab: Modify 
Configuration 
 Lab: 
Troubleshooting 
PRAC and 
PID 
Adding and Modifying 
Activity Modules 
Adding and Modifying 
Hybrid 
Activity Modules 
Troubleshooting 
CCT 
Day 1 Day 2 Day 3 Resources 
Labs Resources Lessons 
14
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Scratch Pad 
Day 2 Day 3 Resources Day 1 
Labs Resources Lessons 
Mobile Access Portal 
(MAP) 
15
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
 
 
 
 
 
Course Objectives 
After completing this course you should be able to: 
 Upload and download both single and multiple controllers
 Troubleshoot software connections
 Modify inputs and outputs
 Commission programs
 Create applications
 Make alterations to programs in CCT
 Analyze data flow
 Assess logic blocks
 Modify configurations
 Troubleshoot in CCT
16
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Module One: 
Uploading and Downloading 
A Single Controller 
17
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Module Objectives 
After completing this module you should be able to: 
 Designate the hardware device to receive the download.
 Launch the Load function in the tool, designate the Load
mode, and verify basic settings.
 Compare versions of firmware code in the application and the
target controller.
 Select the operations to perform and initiate the Load.
18
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Module One: Uploading and Downloading a Single Controller 
Time : 70 Minutes 
Selecting the Target Device 
Lab: Uploading and Downloading a Single Controller 
Loading Function Settings 
Device Selection 
 Additional Notes 
19
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Uploading and Downloading a Single Controller 
Selecting the Target Device 
 Identify the target devices and addresses
 Start the tool
 Open the Controller Application File (.caf)
 Review and update hardware definitions and
addresses in the application file
20
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Uploading and Downloading a Single Controller 
Loading Function Settings 
 Click Load. The Load Device wizard appears.
21
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
 Select settings.
 Load Type:
 Upload: Copy .caf from the
controller to the laptop.
 Download: Copy .caf from
the laptop to the controller.
 Uploading and Downloading a Single Controller 
Loading Function Settings (Cont'd.) 
22
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Uploading and Downloading a Single Controller 
Loading Function Settings (Cont'd.) 
Note: Connection Type and Parameter settings from the last connection used 
are recalled. 
 Select Connection Parameters based on the Connection Type.
 Ethernet:
 Host Name/IP Address: Select
from a list of devices. The Browse
[ … ] button allows you to manage a
list of host names/addresses.
 User Name and Password: Enter
the appropriate credentials for the
device to which you are connecting.
 Supervisory Device and Trunk:
This feature allows you to select the
appropriate device and MS/TP trunk
on that device when using an IP
connection.
23
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
 Bluetooth®
 Baud Rate: Should be 38400
for Johnson Controls controllers
 Bluetooth® COM Port: Serial client
port established in Bluetooth®
pairing
Uploading and Downloading a Single Controller 
Loading Function Settings (Cont'd.) 
 Select Connection Parameters based on the Connection Type.
24
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
 BACnet® Router:
 Address: IP address of the
BACnet® router
 UDP Port: Default port number is
47808
 Network Number: The BACnet®
instance of the MS/TP trunk
(0 – 99,999)
Note: Do not use 1001 for the
MS/TP Network Number
 Network Interface: Select an
available network interface adapter
to use (if selected all IP traffic
intended for the BACnet® router
travels through this interface)
Uploading and Downloading a Single Controller 
Loading Function Settings (Cont'd.) 
 Select Connection Parameters based on the Connection Type.
25
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
 ZigBee®
 PAN Offset: Match the PAN offset
used by the ZFR Wireless
coordinator on the wireless network
to which you wish to connect.
Note: wireless / Bluetooth® devices
on your computer may need to be
disabled for the Zigbee® adapter to
function properly.
Uploading and Downloading a Single Controller 
Loading Function Settings (Cont'd.) 
 Select Connection Parameters based on the Connection Type.
26
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
 Discovery:
 Auto: Leave as Auto unless
instructed by Technical Support.
 Manual: You must provide the
address of the MS/TP bus device
to which you wish to connect.
Uploading and Downloading a Single Controller 
Loading Function Settings (Cont'd.) 
 Select Connection Parametersbased on the Connection Type.
27
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Check Your 
Knowledge 
Please vote in the WebEx Poll panel 
a. Ethernet
b. Bluetooth®
c. ZigBee®
d. The last connection setting
used
e. BACnet® Router
Which of the following Connection Types is the default selection? 
28
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
 Upload (shown): Displays all the devices on MS/TP trunk.
 Download: Only devices that have the address of the loaded controller file
can be downloaded.
 All addressable devices connected to the Sensor Actuator bus of the device will also
show up.
Note: Devices must be assigned to hardware for download.
 Select the device to upload or download and click Next.
Uploading and Downloading a Single Controller 
Device Selection 
Click Next. The Device Selection page appears. 
29
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
The Load Summary page appears. 
 If desired, select the check box Close wizard after successful upload.
 Click Finish to begin the upload.
Uploading and Downloading a Single Controller 
Upload Operation 
30
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Upload Operation in progress. 
Uploading and Downloading a Single Controller 
Upload Operation (Cont'd.) 
The Load Device wizard will close 
when the upload is completed if 
that option is selected. 
31
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
When the upload is complete: 
 The uploaded file is displayed in the tool with the file name upload.caf. You
may then select Save or Save As from the File menu to keep a copy of the
uploaded file.
 System information about the uploaded file is displayed in the Status bar.
Uploading and Downloading a Single Controller 
Upload Operation (Cont'd.) 
32
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
If the uploaded file was created with an 
older version of the tool, you will be 
prompted to upgrade the system or switch 
to the release (if 10.0 or greater). Select as 
appropriate for your needs. 
 If you select Upgrade:
 Standard Modules listed will be upgraded.
Any User Modified Modules will not be
upgraded.
 If you select switch:
 Controller Tool will switch to the release of
the upload.
 If you select open Read Only
 You will not be able to make changes to
the file.
Uploading and Downloading a Single Controller 
Upload Operation (Cont'd.) 
33
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Uploading and Downloading a Single Controller Upload Operation 
Let’s see 
this in 
action 
Video: 
Upload a controller 
34
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
When the load type selected is Download To Device, after you click Next on the 
Device Selection screen, the Load Summary page appears. 
 Compare Controller and Tool code versions.
 Boot and Main code are automatically selected if the file was upgraded.
Uploading and Downloading a Single Controller 
Download Operation 
Controller 
Tool 
35
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Select the load operations to be performed and click the Finish button to initiate 
the download. Normally, you would use the default settings. 
Uploading and Downloading a Single Controller 
Download Operation (Cont'd.) 
The fault LED on the controller indicates the controller status during downloads: 
Boot – Light should be blinking. 
Main – Light should be On solid. 
Application – Light is On solid, followed by blinking as the download finishes, then goes off. 
36
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Progress is indicated as the download proceeds. When the Download Operation 
is complete, the Load Device wizard will close if that option was selected. 
Uploading and Downloading a Single Controller 
Download Operation (Cont'd.) 
The fault LED on the controller indicates the controller status during downloads: 
Boot – Light should be blinking. 
Main – Light should be On solid. 
Application – Light is On solid, followed by blinking as the download finishes, then goes off. 
37
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Uploading and Downloading a Single Controller Download 
Operation 
Watch 
how this 
works 
Video: 
Downloading a single 
controller 
38
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
When downloading a controller as an N2 replacement device, there are 
additional considerations and the steps are slightly different. 
 You must connect directly to the SA port of a compatible controller via the
BTCVT (other connection types can not be used).
 The CAF file must be properly configured for N2
compatibility.
 Boot and Main code must be loaded first.
 Select the option to Switch Communication
Mode before application code can be
downloaded.
Uploading and Downloading a Single Controller 
Download as N2 Controller 
Note: Refer to JCI LIT-12012005 - Modernization guide for N2 controllers for 
more information
39
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Make sure you connect directly to the SA port of the controller with a BTCVT. 
Uploading and Downloading a Single Controller 
Download as N2 Controller (Cont’d.) 
Note: In this example, 
the controller code will 
also be upgraded. 
Communication mode 
before download. 
40
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Make sure you connect directly to the SA port of the controller with a BTCVT. 
Uploading and Downloading a Single Controller 
Download as N2 Controller (Cont’d.) 
Communication mode 
after download. 
41
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Check Your 
Knowledge 
Please vote in the WebEx Poll panel 
When the Load Type; Download To Device is selected, what 
screen appears next after you click Next? 
a. System Upgrade Notification
b. Device Selection Screen
c. Load Summary Screen
d. Load Device Wizard42
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
 If you are downloading N2 compatible controllers, you must use the SA bus. In
addition, with the Load Wizard, the Main code initially downloads as MS/TP
(Wired Field Bus), but switches to N2 (N2 Slave Field Bus) when you select
the Switch Communication Mode check box on the Load Summary screen.
 If the communication protocol in the controller does not match the protocol
that is used in the application, you must switch communication modes before
you download an application.
 When you upgrade field controllers with I/O Module devices on the SA Bus,
you may need to upgrade certain devices to the latest release before you
download the application. If this workflow is required, an alert appears that
indicates which device requires an upgrade.
 For some devices, regardless of the download code order you choose, a
message appears prompting you to install the Boot code before applying the
Main code. The upgrade process does not proceed unless you perform this
action.
Uploading and Downloading a Single Controller 
Additional Notes 
Keep in mind the following when downloading a device: 
43
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Keep in mind the following when downloading a device: 
 If you are downloading devices over the Sensor/Actuator (SA) Bus, first
download the individual device to which you are connected and then
download the remaining devices.
 If you need to load Main code into an I/O Module device on the SA Bus, it is
one to two minutes (30%) faster per I/O Module devices if you are directly
connected to the SA Bus with a Bluetooth® connection. The typical download
time is 3-1/2 minutes for an SA Bus download and nearly 5 minutes for an FC
Bus connection.
Uploading and Downloading a Single Controller Additional Notes 
on Downloading a Device (Cont'd.) 
44
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Uploading and Downloading a Single Controller Additional Notes 
on Downloading a Device (Cont'd.) 
Important: The Tool detects and downloads ZFR1811/FX-ZFR1811 radio code even when the field 
controller Main and Boot code match the tool versions but the Radio code version does not match. 
The tool detects the versions of the Boot, Main, and Radio code versions in the field controller if you 
attempt to download an application. If the Boot or Main code version in the controller does not match 
the software version, the tool selects the Boot or Main check box. The Radio code is downloaded with 
the Main code. However, if the Boot and Main code versions in the tool match the code in the field 
controller but the Radio code version does not, the tool does not automatically select the Boot code 
and Main code check boxes. If the Main code check box is not selected, the Radio code is not 
downloaded. 
Keep in mind the following when downloading a device: 
 When downloading a ZFR Wireless Field Bus Coordinator, follow the
procedure in this section; however, you do not need to open an application
before discovering the coordinator.
 When downloading ZFR Wireless Field Bus Routers, refer to the ZFR
Wireless Field Bus Router product documentation for guidelines.
 If a ZFR1810 Coordinator has Main code version earlier than Release 5.0, it
should be upgraded.
 
 
 
 
 
45
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Get ready 
to actively 
participate 
46
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Lab Instructions 
1. Scroll to the Downloading and Uploading a Single Controller Lab in the Learner’s Guide.
2. Follow the step-by-step instructions provided in the lab.
3. After completing the lab be prepared to discuss the results. 
Time : 30 Minutes 
47
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Downloading and Uploading a Single Controller Lab 
 Activity 1 Download a Controller via the Bluetooth® Interface 
 Activity 2 Upload a Controller via the Bluetooth® Interface 
Session Overview 
This session consists of a PowerPoint presentation for downloading a controller using CCT, some demonstrations, and a 
lab to reinforce concepts from the demonstration. 
Objective 
After completion of this lab, you will be able to: 
• Download an FEC controller using the Bluetooth® interface.
Contents 
48
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Requirements 
1. Laptop computer with CCT software
2. Wireless Commissioning Converter (BTCVT)
3. An FC bus with MS/TP controllers connected to it. If you have the FEC test panel, configure it so you can see all of the
controllers on the FC bus. If not, connect as many controllers together on an FC bus so you can work with as many as
possible. Please verify that each controller is set to a different device address.
Downloading a controller takes a program from the computer you are working on and loads it into a controller. The 
program is stored in the controller’s flash memory. 
Downloading and Uploading an FEC Controller 
49
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
How do I do it? Helpful Hints and Notes: 
1. Ensure that your computer is Bluetooth® ready from the
earlier lab.
2. Double-click the CCT icon on your desktop.
3. Connect the BTCVT to an available jack on a controller
in the network.
4. Open the program you wish to download from the CCT
main screen by selecting File > Open.
5. If the file requires an upgrade when it is opened, accept
the upgrade and click File > Save.
6. Confirm the address of the controller by clicking Define
Hardware. Click the Network Settings tab.
If you are not sure, refer to the Bluetooth® wireless lab, or 
consult LIT-12011038. 
 This is the CCT icon 
For our lab, connect to the SA/FC bus jack on the face of 
the IOM2710-0 controller. 
If the controller is not operational, consult the Controller 
Information lab, and find and flip the SA/FC switch to FC. 
For this lab, use the program labeled Fan Coil.caf that you 
downloaded prior to the beginning of the class. 
CCT version changes require controller file upgrades. If 
you are upgrading from 10.0 or 10.1 to 10.2 upgrade the 
file, do not switch the revision level to the older revision. 
The device address must match the switch settings on the 
FEC controller. 
Activity #1: Download a Controller via the Bluetooth® Interface 
50
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing.Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
How do I do it? Helpful Hints and Notes: 
7. If necessary, change the address to 5, and click Close
to save the file again.
8. Click the Load button.
9. Select a connection type of Bluetooth® and make sure
your Bluetooth® serial port is entered
10.Select the Download to Device radio button and click
Next.
11.On the Device Selection screen, click the controller
you wish to download, and then click Next.
Selecting Download places the program from your 
computer in the controller. Choosing Upload brings the 
program from the controller to the computer. 
For our lab, select the controller at address 5. It should 
show up with a local display at address 3. The display is on 
the SA (sub) bus. 
If this controller does not show up, check the address 
switches on the controller. 
You might also confirm that the switch settings on the FEC 
are set to 5. The first and third switches should be on and 
all other switches should be off. 
51
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
How do I do it? Helpful Hints and Notes: 
12.On the Load Summary screen, compare the Main
Code and Boot Code versions in the controller with the
one on the computer. If they are the same, click the
Application box, and then click Finish. If they are
different, click the boxes next to Main, Boot, and
Application, and then click Finish.
13.Click Tools > Controller Information. The principles from the Controller Information lab can be 
used to confirm that the code you just loaded into the FEC 
is operational in controller 5. 
Your equipment should already have the correct Main 
Code. You can select the Main Code download to see how 
it works. You may have to download Main and Boot code in 
some devices. 
Normally, CCT will automatically select the appropriate 
download check boxes. 
52
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Activity #2: Upload a Controller via the Bluetooth® Interface 
How do I do it? Helpful Hints and Notes: 
1. Ensure that your computer is Bluetooth® ready.
2. Double-click the CCT icon on your desktop.
3. Connect the BTCVT to an available jack on a controller
in the network.
4. Click the Load button.
5. Ensure the Bluetooth® is selected and the correct serial
port is entered
6. Select the radio button for load type Upload, and then
click Next.
7. After the discovery is complete, click the controller you
wish to upload, and then click Next.
If you are not sure, refer to the Bluetooth® wireless lab, or 
consult LIT-12011038. 
For our lab, connect to the SA/FC bus jack on the face of 
the IOM2710-0 controller. 
Upload brings the program from the controller to the 
computer. 
The program will examine the bus and give you a list of all 
controllers that might be uploaded. 
 This is the CCT icon. 
For our lab, select the controller at address 5. 
53
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
How do I do it? Helpful Hints and Notes: 
8. On the Load Summary screen, click Finish. There will be a bar progressing across the bottom of your 
screen as the upload progresses. 
The Load Device wizard will close automatically if “Close 
wizard after successful upload” is selected. If it is not 
selected, click Done to close the wizard. 
Your upload is now finished. At this point, you could save the program by selecting File > Save or Save As to place the 
program in the CCT project directory. 
You have successfully completed this lab. 
54
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Discussion 
55
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
 To upload a single controller the target devices and addresses are identified.
 Function settings need to be loaded and connection parameters selected
based on the connection type.
 Only the devices that are on the MS/TP trunk are displayed on the Device
Selection Page and only devices that have the address of the loaded
controller file can be downloaded.
 Uploaded files are displayed as upload.caf and system information about the
uploaded file is displayed in the Status bar.
 There are additional requirements for downloading a
controllers as an N2 replacement
 
 
Module One: Uploading and Downloading a Single Controller 
(Key points) 
56
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Module Two: 
Uploading and Downloading 
Multiple Controllers 
57
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Module Objectives 
 Download .caf and attributes to multiple controllers of the same type.
 Connect to a controller and define read and write attributes.
 Save and load saved attributes.
 Upload and download multiple controllers and attributes.
 Upload a network.
58
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Module Two: Uploading and Downloading Multiple Controllers 
Time : 60 Minutes 
Trunk Utilities Menu 
Lab: Uploading and Downloading Multiple Controllers 
Download to Same Controller Type 
Download to Multiple Different Controllers 
Upload Multiple Controllers 
59
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Uploading and Downloading Multiple Controllers 
Trunk Utilities Menu 
There are different functions available depending upon whether or not there is a 
CAF file open. 
File Open No File Open 
60
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Uploading and Downloading Multiple Controllers Download to 
Same Controller Type 
To download the same CAF file to multiple controllers of the same type: 
 Start with the relevant file opened in the tool.
 Select Tools > Trunk Utilities > Download CAF & Attributes.
 Select the connection type and click Next.
 When Connected, click Discovery to view the controllers on the trunk.
61
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product LiteratureResources 
Continue by selecting the desired devices. The controllers that are to be 
downloaded, must be of the same type, e.g., select multiple VAV controllers. 
Uploading and Downloading Multiple Controllers with the Tool: 
Download to Same Controller Type (Cont'd.) 
62
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
If needed, attributes may be selected, read, and written to the selected 
controllers. Click Next to skip this step and proceed to downloading controllers. 
Uploading and Downloading Multiple Controllers with the Tool: 
Download to Same Controller Type (Cont'd.) 
Select Object/Parameter and 
attribute, then click OK. 
63
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
If needed, attributes may be selected, read, and written to the selected 
controllers. Click Next to skip this step and proceed to downloading controllers. 
 Reading and Writing attributes are much faster than a full upload or download.
 Different values may be written to each selected controller for a particular
attribute.
 The list of attributes and selected controllers may be saved and reused later.
Uploading and Downloading Multiple Controllers with the Tool: 
Download to Same Controller Type (Cont'd.) 
64
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
 Select the controllers to download. Click Finish to proceed.
 If needed, Boot and Main Code may also be downloaded.
 A download template containing the list of controllers can be saved/reused.
Uploading and Downloading Multiple Controllers with the Tool: 
Download to Same Controller Type (Cont'd.) 
Note: If you are connected to the bus through a controller, that controller should 
be upgraded first by itself before upgrading and downloading other controllers. 
65
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Progress is indicated as each controller is downloaded. 
Uploading and Downloading Multiple Controllers with the Tool: 
Download to Same Controller Type (Cont'd.) 
66
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Status is reported as the downloads are completed. 
 Status for selected controllers may be viewed.
 A log of controllers downloaded may also be viewed and/or cleared.
 Either may be copied to the clipboard for inclusion in other project
documentation.
 
Uploading and Downloading Multiple Controllers with the Tool 
Download to Same Controller Type (Cont'd.) 
67
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Uploading and Downloading Multiple Controllers Download to 
Multiple Different Controllers 
You can use the tool to download multiple different controllers with different 
applications, all in one download session. 
 Start the tool with no file open or, close any CAF file you may be working with.
 Select Tools > Trunk Utilities > Download Multiple CAFs.
 Select the connection type.
 Discover the controllers.
Optionally, you may open a previously saved download template.
 Select desired controllers, CAF, and parameter files.
 Optionally, assign names to each controller.
 Controller Boot and Main Code may also be upgraded.
 You may also save your list for later use as a Download template.
 Select Finish to download all the CAF files with a single command.
68
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Let’s take 
a look. 
Uploading and Downloading Multiple Controllers with the Tool 
Download to Multiple Different Controllers (Cont'd.) 
Video: 
Downloading multiple 
controllers from one caf
69
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
After selecting the connection type, click Discovery to view the connected 
controllers. 
Optionally, you may save or browse for and select a previously saved Download 
template. If you chose this option, use the Get Device Info button to verify 
controller code versions. 
Uploading and Downloading Multiple Controllers with the Tool 
Download to Multiple Different Controllers (Cont'd.) 
70
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Select the desired controllers for download. 
 Browse and select .caf and (optionally) attribute files for each selected controller.
 You can also assign names and BACnet® IDs to each controller (optional).
Attribute templates are not required. 
Uploading and Downloading Multiple Controllers with the Tool 
Download to Multiple Different Controllers (Cont'd.) 
71
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Boot and/or Main Code may also be downloaded to upgrade controllers. 
If you are connected to a controller on the SA bus via Bluetooth®, be sure to 
download that controller individually first to help prevent download errors. 
Uploading and Downloading Multiple Controllers with the Tool 
Download to Multiple Different Controllers (Cont'd.) 
72
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Click Finish to begin the download of the selected controllers and attributes. 
 
 
 
 
 
 
Uploading and Downloading Multiple Controllers with the Tool 
Download to Multiple Different Controllers (Cont'd.) 
73
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
The status and progress of the download is displayed as it proceeds. 
 
Uploading and Downloading Multiple Controllers with the Tool 
Download to Multiple Different Controllers (Cont'd.) 
74
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
You can save the list of controllers in a Download template for later use. 
 Status for selected controllers may be viewed.
 A log of controllers downloaded may also be viewed and/or cleared.
 Either may be copied to the clipboard for inclusion in other project
documentation.
 
 
Uploading and Downloading Multiple Controllers with the Tool 
Download to Multiple Different Controllers (Cont'd.) 
75
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
cUploading and Downloading Multiple Controllers with the Tool 
Download to Multiple Different Controllers 
Let’s take 
a look. 
 
 
Video: 
Download multiple 
controllers with multiple 
CAF files 
76
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Uploading and Downloading Multiple Controllers 
Upload Multiple Controllers 
This allows you to simply upload the controller application files (.caf ) from multiple 
controllers on the same FC bus in one session. 
 Start the tool with no file opened.
 Select Tools > Trunk Utilities > Upload Multiple CAFs.
 Select the connection type.
 Specify the directory where you want the controller application files to be uploaded.
 Click the Discovery button to find and then select different controllers. Optionally, you
may use a previously saved Download template to list the controllers.
 Select Finish to upload the CAF files from selected controllers with a single command.
 Files are stored in the directory, selected, and named from the system name of the
controller, followed by an underscore, then the controller address number. For example:
Fan Coil_35.caf 
System Name 
from Controller An Underscore 
Controller Switch 
Address Number 
77
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
 After connecting, click Select Directory to choose an appropriate location to
save the uploaded files.
 Then, click Discovery to locate the controllers on the FC bus.
Optionally, you may browse for and open a previously saved Download
template for the list of controllers to be uploaded.
 Select the controllers to upload. Click Finish to start the upload.
Uploading and Downloading Multiple Controllers with the Tool 
Upload Multiple Controllers (Cont’d.) 
78
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Progress is reported as the uploads proceed. When it is finished, you may 
perform any of the following: 
 Save the list of controllers to a Download template for later use.
 Status for selected controllers may be viewed.
 A log of controllers uploaded may also be viewed and/or cleared.
 Either may be copied to the clipboard for inclusion in other project
documentation.
 
Uploading and Downloading Multiple Controllers with the Tool 
Upload Multiple Controllers (Cont’d.) 
79
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
This feature allows you to update the boot and radio code for selected ZFR 
wireless devices. It is only available with no .caf file open. 
From the Tools menu, select Trunk Utilities > Download ZFR. The Trunk 
Utilities - Download ZFR wizard appears with the Connection screen active. 
Pick your connection type, and then click Next. 
 
 
Trunk Utilities Download ZFR 
80
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
When the Download screen indicates that you are connected, you can click 
Discovery to find devices. 
After devices are listed, you can select the ones you wish to upgrade. Boot and 
Main code can be forced to be downloaded. 
Click Finish to perform the upgrade and view the progress of the download for 
the selected devices. 
 
Trunk Utilities Download ZFR (Cont’d.) 
81
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
The Read/Write Attributes Online utility allows you to mass 
edit the attributes of online controllers using attribute templates 
and read/write functionality. You can access this utility from the 
Tools menu by selecting Trunk Utilities > Read/Write 
Attributes Online. 
This utility has the same Connection and Device Selection screens as the 
Load Device wizard. 
 
 
Trunk Utilities Read/Write Attributes Online 
Note: When a .caf file is not loaded, you cannot add attributes. You may only 
remove attributes or add, delete, or modify the devices as well as save the 
template. 
82
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Devices may be discovered 
or added manually. 
Only selected devices will 
be read/written to. 
 
Trunk Utilities Read/Write Attributes Online (Cont'd.) 
Note: The Device Name and Instance Number are only written during the 
download process. These values cannot be written during a read/write operation. 
The Instance Number can be assigned or calculated automatically by right-
clicking on that column. 
83
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Attributes are added by clicking the column. Select the object and desired 
attribute from the tree view. By default, only BACnet® exposed items are 
displayed. The Show All option allows other attributes to be selected. 
Trunk Utilities Read/Write Attributes Online (Cont'd.) 
84
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Attributes templates may be saved and opened again for later use. 
Device Name and selected attribute values may be read, modified, and written 
for the selected controllers. 
Trunk Utilities Read/Write Attributes Online (Cont'd.) 
85
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Be sure to save the changes to an Attribute Template if you want to use it later. 
Device Name and Instance Number may only be modified by downloading the 
controller. These may be assigned and/or calculated automatically by right-
clicking the column. 
Selected attribute values initially come from the .caf file. But these may be read, 
modified, and written for the selected controllers. 
Trunk Utilities Read/Write Attributes Online (Cont'd.) 
86
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
The Manage Attribute Templates feature allows you to create 
or modify these templates without connecting to controllers to 
changes to the controllers. 
Trunk Utilities Manage Attribute Templates 
Note: When a .caf file is not loaded, you cannot add attributes. You may only 
remove attributes, and add, delete, or modify the list of devices. 
87
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
The Upgrade Multiple Controllers trunk utility allows youto 
upgrade .caf files from multiple devices on the same trunk. 
You can access this utility from the Tools menu by selecting 
Trunk Utilities > Upgrade Multiple Controllers. This menu 
option is only available when a .caf file is not open. 
It is not recommended to use Ethernet pass-through connection for upgrading 
multiple controllers due to potential communications loss during the process. 
It is recommended that you upgrade one device first, before upgrading an entire 
trunk. 
Trunk Utilities Upgrade Multiple Controllers 
88
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
When multiple controllers are selected to upgrade, each will 
go through the following steps: 
 An upload of the application
 An upgrade of the .caf, if needed
 A download of Boot and/or Main code, if needed
 A download of the upgraded .caf file, if needed
Status is updated for each step as it progresses. You may use the View Log and 
View Status as well to monitor the progress. 
Trunk Utilities Upgrade Multiple Controllers (Cont’d.) 
Note: An I/O Module Device on the SA bus of a 
controller must be upgraded before the controller can 
be upgraded. 
89
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
If present, pay careful attention to the caution for wireless devices. 
Click Finish to begin the process for the selected controllers. 
Trunk Utilities Upgrade Multiple Controllers (Cont’d.) 
Save the 
list of 
controllers. 
Browse for 
and open a 
previously 
saved list. 
Use the 
Discovery 
button to 
find the 
controllers 
on a trunk. 
Selected 
controllers 
90
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Uploading and Downloading Multiple Controllers with the Tool 
Upload Multiple Controllers 
Let’s see 
how this 
works. 
Video : 
Upload Multiple 
Controllers 
91
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Module Two: Uploading and Downloading Multiple Controllers 
(Key points) 
 There are different functions available in the Trunk Utilities Menu depending
on whether or not there is a .caf file open.
 The same .caf file can be downloaded to multiple controllers.
 The tool can also be used to download multiple different controllers with
different applications, all in one download session.
 The controller application files (.caf ) from multiple
controllers may also be uploaded on the same
FC bus in one session.
 Progress and status can be reviewed during
a download or upload process.
 
 92
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Get ready 
to actively 
participate 
93
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Lab Instructions 
1. Scroll to the Downloading and Uploading Multiple Controllers Lab in the Learner’s Guide.
2. Follow the step-by-step instructions provided in the lab.
3. After completing the lab be prepared to discuss the results. 
Time : 60 Minutes 
94
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
 Activity 1 Downloading and Uploading Multiple Controllers with CCT 
 Activity 2 Downloading and Uploading Attributes with CCT 
 Activity 3 Download many controller with CCT 
 Activity 4 Upload Many Controllers with CCT 
Session Overview 
This session consists of a lab to reinforce concepts from the instructor-led course content. 
Contents 
Downloading and Uploading Multiple Controllers Lab 
95
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Activity #1: Downloading and Uploading Multiple Controllers with CCT 
Requirements 
• Laptop computer with CCT software.
• Wireless Commissioning Converter (BTCVT).
• An FC bus with MS/TP controllers connected to it. If you have the FEC test panel, configure it so you can see all of
the controllers on the FC bus. If not, connect as many controllers together on an FC bus so you can work with as
many as possible. Please verify that each controller is set to a different device address.
Estimated Time 
This exercise takes about 60 minutes to complete. 
 Download Multiple Controllers and Attributes Using the Same .caf File
How do I do it? Helpful Hints and Notes: 
1. Ensure that your computer is Bluetooth® ready.
2. Double-click the CCT icon on your desktop.
3. Connect the BTCVT to an available jack on a controller
in the network.
If unsure, refer to the Bluetooth® Wireless lab, or consult 
LIT-12011038. 
 This is the CCT icon. 
For our lab, connect to the SA bus jack on the FEC 
controller. 
96
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
How do I do it? Helpful Hints and Notes: 
4. Open the pre-built fan coil file. 
 
 
 
 
5. Click Tools > Trunk Utilities > Download CAF & 
Attributes 
 
6. Select the radio button for Bluetooth® and make sure 
that the Bluetooth® COM port is the same that you 
wrote down earlier. Click Next. 
 
 
7. Wait while the connection is made and then click the 
Discovery button. 
 
 
8. After discovery is complete, clear the controllers you do 
not want to update. 
 
9. Type in the instance number to download to the device 
and change its name, if needed. In this case, use an 
instance of 5005 and device name as fan coil. 
For our class, use Fan Coil.caf. 
The pre-built fan coil file was downloaded from the class 
support site 
 
 
 
 
 
 
 
 
 
 
You should only select a controller or controllers that can 
handle the file you have opened, that is, FEC controllers 
that will be serving a fan coil system. 
 
 
 
 
The instance number is a unique number identifying the 
controller to BACnet®. 
97
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
How do I do it? Helpful Hints and Notes: 
10.Select the Click To Define New Attribute column
header.
11.From the list of BACnet® exposed objects, scroll down
to Logic > Setpoint/Miscellaneous > ZN-T Setpoint
Determination, and select CLGOCC-SP. On the right
hand side, select Default Value.
12.Click OK.
13.Change the default value to 76.
This will open the Select Attribute window. Attributes are 
internal controller values that might normally show up on 
the Parameters tab in CCT. 
We will only download one controllerin this example, but 
you can load the same CAF file simultaneously to many 
controllers that have the same function and are on the 
same trunk. 
98
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
How do I do it? Helpful Hints and Notes: 
14.Select the Click To Define New Attribute column
header again. This time select HTGOCC-SP from the
same ZN-T setpoint determination block. On the right
hand side, select Default Value.
15.Define a new column and select ZNT-SP from Network
inputs.
16.Define a new column and select EFFCLG-SP from ZN-
T Setpoint Determination.
Your screen will look similar to this:
17.Click Save at the top of the screen, using a name of
Fan Coil Attribute template and save it to the desktop.
18.Clear ZNT-SP and EFFCLG-SP.
Change this default value to 72. 
Select Present Value as the data type on this one. 
Select Present Value for this one. 
This allows you to reuse the template. In your system, you 
might want to create an Attribute directory for your 
particular job. 
You cannot download these values. You will get a 
message, telling you this, on the next screen. 
99
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
How do I do it? Helpful Hints and Notes: 
19. In the column below Selected, select the controllers
you want to update.
20.Click Next > Finish to complete the download.
21. Watch the download action in the Status column.
22.Click Cancel.
23.After completion, select Trunk Utilities > Read/Write
Attributes Online, and then select the fan coil. Click
Next, and then click the Browse button, and load the
Fan Coil Attribute template.
24.Make sure everything is selected. Click Read
Attributes.
If you download multiple controllers, all the attributes could 
be different. This would be useful especially with the VAV 
controllers. 
You can click (and refresh) the View Status button to see 
details about the download. 
100
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
How do I do it? Helpful Hints and Notes: 
Leave Selected checked. In this case, clear Htg, Clg, and 
effective setpoints. 
If you thought, “The Effective Setpoint is determined by the 
occupied heating and cooling setpoints and is adjusted by 
the network setpoints,” then you were right. 
25.What i s the valu e of ZNT-SP?
__________________________________________
What i s the valu e of EFFCLG-SP?
__________________________________________
26.Clea r everything except ZNT-SP.
27.Mak e ZNT-S P equal t o 7 6 and click Writ e Attributes. 
Clic k OK.
28.Select everythin g again, an d clic k Rea d Attributes.
29.Now, what i s th e valu e of EFFCLG-SP?
__________________________________________
30.Wh y d o yo u think thi s happened?
__________________________________________
101
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
How do I do it? Helpful Hints and Notes: 
31.Select Click to Define New Attribute > Hardware > 
Inputs > ZN-T, and select Present Value. Click OK. 
 
32. Click Read Attributes. 
 
 
 
33.Save the attribute file. 
 
34.Click Finish. 
 
 
 
You will notice that ZN-T reads 0. There is a problem with 
the program that we will fix and then return to trunk 
utilities. 
102
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Activity #2: Downloading and Uploading Attributes with CCT 
How do I do it? Helpful Hints and Notes: 
1. Ensure that your computer is Bluetooth® ready.
2. Double-click the CCT icon on your desktop.
3. Connect the BTCVT to an available jack on a controller
in the network.
4. Do not open a CAF file. If one is already opened, click
File > Close.
5. Click Tools > Trunk Utilities > Read/Write Attributes
Online.
6. Select the radio button for Bluetooth® and make sure
your Bluetooth® COM port is the same that you wrote
down earlier. Click Next.
7. Wait to verify connection, and then click Discovery.
If unsure, refer to the Bluetooth® Wireless lab, or consult 
LIT-12011038. 
 This is the CCT icon. 
For our lab, connect to the SA bus jack on the FEC 
controller. 
When you read and write attributes, all controllers that are 
selected, need to have the same attributes in their 
program. 
In this case, select the fan coil you have been working with. 
103
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
How do I do it? Helpful Hints and Notes: 
8. Click Browse, locate the file you saved on the desktop 
called Fan Coil Attribute template, and then click 
Open. 
This is a file that can be transferred from one computer to 
the other as well. 
Q1) What are the occupied cooling and heating setpoint defaults for fan coil? 
Using Help, answer the following questions: 
Heating _______________________________________________________________________________________ 
 
Cooling _______________________________________________________________________________________ 
How do I do it? Helpful Hints and Notes: 
9. Click Read Attributes. This quickly gets the values from the controllers and places 
them in memory. If they have been changed, you will see 
the change reflected here. 
104
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Q2) Did the values you read agree with the default values? 
How do I do it? Helpful Hints and Notes: 
10.Change the setpoints to 75 and 71, respectively. Clear 
all except CLGOCC-SP and HTGOCC-SP, and then 
click Write Attributes. 
 
11.Change the setpoints to 76 and 72, and click Read 
Attributes. 
You should receive a write successful message. 
Q3) Did the values go back to 75 and 71? 
105
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
How do Ido it? Helpful Hints and Notes: 
12.Click Finish to complete the attribute read/write
process.
106
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Activity #3: Download many controllers with CCT 
 Download Many Controllers via the Bluetooth® Interface
How do I do it? Helpful Hints and Notes: 
1. Ensure that your computer is Bluetooth® ready.
2. Double-click the CCT icon on your desktop.
3. Connect the BTCVT to an available jack on a controller
in the network.
4. Do not open a CAF file. If one is already open, click
File > Close.
5. Click Tools > Trunk Utilities > Download Multiple
Controllers.
6. Select the radio button for Bluetooth® and make sure
your Bluetooth® COM port is the same that you wrote
down earlier. Click Next.
If unsure, refer to the Bluetooth® Wireless lab or consult 
LIT-12011038. 
 This is the CCT icon. 
For our lab, connect to the SA bus jack on the FEC 
controller. 
107
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
How do I do it? Helpful Hints and Notes: 
7. After the connection is established, click Discovery.
Next, select the FEC and VMA devices by selecting the
box next to the Discovered column.
8. Under application for the fan coil, click the Browse
button, and find the Fan Coil.caf file you have been
using.
9. For the VMA controller, use the VAV Box.caf file in your
class directory.
10.Click Save in the upper right part of this dialog box and
use the name as Multiple Controllers Job 1.
11.Click Finish to complete the download.
Only FEC, VMA, and FAC controllers are selected by 
default when the discovery screen comes up. Third party 
nodes are automatically cleared. 
This allows you to selectively download controllers. 
You can use the same CAF file for all similar controllers. 
Change the name, device address, and BACnet® instance 
number, as appropriate, for each controller. 
 The template can be transferred between computers. 
Use the View Status button to see how the download is 
going. Refresh updates the status. 
108
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Activity #4: Upload Many Controllers with CCT 
 Upload Many Controllers via the Bluetooth® Interface
How do I do it? Helpful Hints and Notes: 
1. Ensure that your computer is Bluetooth® ready.
2. Double-click the CCT icon on your desktop.
3. Connect the BTCVT to an available jack on a controller
in the network.
4. Do not open a CAF file. If one is already open, click
File > Close.
5. Click Tools > Trunk Utilities > Upload Multiple
Controllers.
6. Select the radio button for Bluetooth® and make sure
your Bluetooth® COM port is the same that you wrote
down earlier. Click Next.
If unsure, refer to the Bluetooth® Wireless lab or consult 
LIT-12011038. 
 This is the CCT icon. 
For our lab, connect to the SA bus jack on the FEC 
controller. 
109
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
How do I do it? Helpful Hints and Notes: 
7. After the connection is established, click Select
Directory.
8. On the Controller Upload screen, click Discovery.
When completed, select all the controllers except TEC
by selecting the box next to the Discovered column.
Click Finish.
9. Click Finish to upload the controllers.
10. Select Done when complete.
Use the desktop to save these files. 
Use the View Status button to see how the upload is 
going. Refresh updates the status. 
You have completed this lab. 
110
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Discussion 
111
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Module Three: 
Troubleshooting Software 
Connections 
112
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Module Objectives 
 Perform an analysis of some of the software modules (using the Help and
other tools such as View Connections, View Logic, Simulator, etc.), given a
simple commisioning tool standard system configuration.
 Perform an analysis of State-based Control.
113
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Module Three: Troubleshooting Software Connections 
Time : 25 Minutes 
Commissioning Data Flow 
View Connections 
State Based Control 
114
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
Usually, the data flows from left to right in Commissioning applications. Inputs 
are typically connected to and evaluated by modules in the 
Setpoint/Miscellaneous column. 
Setpoint/Miscellaneous outputs flow into State Generation modules, where the 
modes or states of the different subsystems are determined. 
State Generation outputs flow into the State Table. 
State Tables pass values to Output Control modules. 
Output Control modules pass signals to the Outputs themselves. 
Input Values Setpoint/Miscellaneous 
Values State Generation Setpoint/Miscellaneous 
State State Generation State Tables 
State Tables Mode Output Control 
Values Outputs Output Control 
Troubleshooting Software Connections 
Commissioning Data Flow 
115
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
LV Blocks cause the data to flow from right to left in Commissioning applications. 
 State Generation modules often need a lockout value from an
output controller.
 Output Control modules pass signals to the LV Blocks, which are then
passed back to the State Generator modules.
 LV Blocks are always used when the result of a process is fed back into
a process.
Data Flow in the Commissioning Programs (Cont'd.) 
State State Generation State Tables.. 
State Tables.. Mode Output Control 
Values LV Block Output Control 
Note: At revision 6.0 or higher, LV blocks can be hidden. 
116
Co
py
rig
ht 
20
16
 by
 Jo
hn
so
n C
on
tro
ls,
 In
c
Our Policy prohibits printing. Save GREEN. 
Excellence in Training 
Online Product Literature 
Resources 
 Select the ZNT-SP network input followed by the Connections tab in the
Features panel.
 Note that the output of the ZNT-SP network input is connected to the Network

Continue navegando