Baixe o app para aproveitar ainda mais
Prévia do material em texto
Commissioning & Standard Programming with CCT : Learner Guide 10236DV001 Our Policy prohibits printing. Save GREEN. 1 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources How to use your Learning Guide Your Learning Guide is intended to facilitate your participation and learning both during the course and after your finish the facilitated three day session. During the Facilitated Session: During the session you might want to consider having two monitors available. On the one monitor you can view the WebEx presentation and on the other you can have your Learning Guide open to quickly access Lab Activities, review previously delivered slides while working with hands-on activities, or use online links to quickly download videos or other resources. You will notice that your Learning Guide has a “home icon” (see image below) on the top of each page. Clicking on the icon will return you to the Table of Contents so you can easily navigate to specific sections of your Guide. 2 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources After the Facilitated Session: After you have completed the facilitated three-day session, you may continue to use your Learning Guide to review pertinent materials while on the job. Optionally, you may decide to watch a video to refresh your memory regarding specific processes. Finally, you may want to simply remind yourself of resources available to you for performing necessary tasks. 3 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Getting Ready: What to Do Before the Course You will be participating in this course using a WebEx connection so it can be taken from your office or home location so it can be taken from your office or home location; just make sure you have a good Internet network connection and phone connection. There are steps, however, that you need to complete to ensure an optimal experience. These include: (1) ensuring you have good computer and phone connections; (2) making sure that you have the proper equipment; and (3) downloading all course materials. Ensuring Your Computer and Phone Connections: Please connect on the Phone Conference and WebEx, at least 15 minutes before the start time, to ensure proper connections before the course begins. Telephone Number for the phone conference: 1-414-214-4100 Internet Browser Address for the WebEx website: Jci.Webex.Com (Note that there is no www or http:// in front of jci.webex.com) Look for the Class called “10236: CCT Class” Select Join, and then enter your name, email and your WebEx Password Note: You will receive an email from your instructor about a week before the class with the webex and telephone conference passwords. 4 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Note: If Join is not immediately available, wait a few minutes, then refresh the web page and look for Join again. Meeting the Computer Requirements: Your computer must have current release of CCT which is Version 10.1 or greater installed. Your CCT Version number can be found by selecting CCT’s Help menu and then select Tool About. Remember, as part of the class you will need an FEC or FAC, a VMA, a BTCVT and a Netsensor is recommended. That was a prerequisite you also needed in the precourse which you have already completed. Downloading Course Materials: Prior to the start of the course go to the BE Class Support Center at: https://my.jci.com/sites/BESalesOpsLearn/Pages/Homepage.aspx Scroll down and navigate to the C-10236 link Download the Course Learner Guide, the CAFs for the course and the videos. (Basically, everything under that C- 10236 directory) You probably want to store these on the hard drive in a directory since you may want to refer to them in the future, so in your my documents directory (or another place you have chosen) make a directory called 10236 and store all these downloads there) Remember that the class will start at 8:00 AM Central time and conclude at 5:00 PM Central time each day [Make sure you recalculate the start time for “your” local time zone.] 5 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Commissioning & Standard Programming with CCT A Single Controller 6 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Throughout the Course you will see Some or all of These Icons Which are Used to Represent Types of Activities, Actions, Resources, Media Inserts or Other Features. Understanding Course Icons Activity Resources Video Tools Scenario Ask an Expert 7 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Accessing Handouts and Support Materials Scroll down and click on the C-10236 folder. Go to the BE Class Support Center at https://my.jci.com/sites/BESalesOpsLearn/CrSp/SitePages/Home.aspx 8 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Using your WebEx Annotation Tools Pointer Type Text Draw Lines or Shapes Pen Select Color Clear Annotations 9 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Prior to participating in this course today you completed the e-learning course: “Introduction to the Controller Configuration Tool” and passed the associated skills and knowledge assessment. 10 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources CCT Basics: Online Learning Summary (Key points) As you may recall from “Introduction to the Controller Configuration Tool”: There is a family of Metasys® Equipment Controllers that operate with Network Automation Engines (NAEs). The Programming Tool is software used with the programmable MS/TP or N2 controllers which has three operating modes. By using Show Involvement you can associate outputs with the modules controlling them. You can identify where Bluetooth® is or can be used, define the port and set up serial linkage to a Bluetooth® device. 11 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Our Policy prohibits printing. Save GREEN. Uploading and Downloading a Single Controller Troubleshooting Software Connections Lab: Downloading and Uploading a Single Controller Uploading and Downloading Multiple Controllers Lab: Commissioning an FCU Lab: VAV Box Flow Test Modifying Inputs and Outputs Commissioning Programs Lab: Commissioning a VAV Lab: Input and Output Commissioning Day 1 Day 2 Day 3Labs Resources Lessons Resources Lab: Downloading and Uploading Multiple Controllers 12 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Our Policy prohibits printing. Save GREEN. Lab: Application Creation Peer to Peer Application Creation Sideloop Lab: Data Flow in CCT Programs Lab: Making Alterations to Programs in CCT State Tables Data Flow and Saturation Timers Day 1 Day 2 Day 3 Resources Labs Resources Lessons 13 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Our Policy prohibits printing. Save GREEN. Logic Blocks MUX Lab: Logic Module and Block Analysis Timers Lab: Modify Configuration Lab: Troubleshooting PRAC and PID Adding and Modifying Activity Modules Adding and Modifying Hybrid Activity Modules Troubleshooting CCT Day 1 Day 2 Day 3 Resources Labs Resources Lessons 14 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Scratch Pad Day 2 Day 3 Resources Day 1 Labs Resources Lessons Mobile Access Portal (MAP) 15 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Course Objectives After completing this course you should be able to: Upload and download both single and multiple controllers Troubleshoot software connections Modify inputs and outputs Commission programs Create applications Make alterations to programs in CCT Analyze data flow Assess logic blocks Modify configurations Troubleshoot in CCT 16 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Module One: Uploading and Downloading A Single Controller 17 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Module Objectives After completing this module you should be able to: Designate the hardware device to receive the download. Launch the Load function in the tool, designate the Load mode, and verify basic settings. Compare versions of firmware code in the application and the target controller. Select the operations to perform and initiate the Load. 18 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Module One: Uploading and Downloading a Single Controller Time : 70 Minutes Selecting the Target Device Lab: Uploading and Downloading a Single Controller Loading Function Settings Device Selection Additional Notes 19 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Uploading and Downloading a Single Controller Selecting the Target Device Identify the target devices and addresses Start the tool Open the Controller Application File (.caf) Review and update hardware definitions and addresses in the application file 20 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Uploading and Downloading a Single Controller Loading Function Settings Click Load. The Load Device wizard appears. 21 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Select settings. Load Type: Upload: Copy .caf from the controller to the laptop. Download: Copy .caf from the laptop to the controller. Uploading and Downloading a Single Controller Loading Function Settings (Cont'd.) 22 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Uploading and Downloading a Single Controller Loading Function Settings (Cont'd.) Note: Connection Type and Parameter settings from the last connection used are recalled. Select Connection Parameters based on the Connection Type. Ethernet: Host Name/IP Address: Select from a list of devices. The Browse [ … ] button allows you to manage a list of host names/addresses. User Name and Password: Enter the appropriate credentials for the device to which you are connecting. Supervisory Device and Trunk: This feature allows you to select the appropriate device and MS/TP trunk on that device when using an IP connection. 23 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Bluetooth® Baud Rate: Should be 38400 for Johnson Controls controllers Bluetooth® COM Port: Serial client port established in Bluetooth® pairing Uploading and Downloading a Single Controller Loading Function Settings (Cont'd.) Select Connection Parameters based on the Connection Type. 24 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources BACnet® Router: Address: IP address of the BACnet® router UDP Port: Default port number is 47808 Network Number: The BACnet® instance of the MS/TP trunk (0 – 99,999) Note: Do not use 1001 for the MS/TP Network Number Network Interface: Select an available network interface adapter to use (if selected all IP traffic intended for the BACnet® router travels through this interface) Uploading and Downloading a Single Controller Loading Function Settings (Cont'd.) Select Connection Parameters based on the Connection Type. 25 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources ZigBee® PAN Offset: Match the PAN offset used by the ZFR Wireless coordinator on the wireless network to which you wish to connect. Note: wireless / Bluetooth® devices on your computer may need to be disabled for the Zigbee® adapter to function properly. Uploading and Downloading a Single Controller Loading Function Settings (Cont'd.) Select Connection Parameters based on the Connection Type. 26 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Discovery: Auto: Leave as Auto unless instructed by Technical Support. Manual: You must provide the address of the MS/TP bus device to which you wish to connect. Uploading and Downloading a Single Controller Loading Function Settings (Cont'd.) Select Connection Parametersbased on the Connection Type. 27 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Check Your Knowledge Please vote in the WebEx Poll panel a. Ethernet b. Bluetooth® c. ZigBee® d. The last connection setting used e. BACnet® Router Which of the following Connection Types is the default selection? 28 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Upload (shown): Displays all the devices on MS/TP trunk. Download: Only devices that have the address of the loaded controller file can be downloaded. All addressable devices connected to the Sensor Actuator bus of the device will also show up. Note: Devices must be assigned to hardware for download. Select the device to upload or download and click Next. Uploading and Downloading a Single Controller Device Selection Click Next. The Device Selection page appears. 29 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources The Load Summary page appears. If desired, select the check box Close wizard after successful upload. Click Finish to begin the upload. Uploading and Downloading a Single Controller Upload Operation 30 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Upload Operation in progress. Uploading and Downloading a Single Controller Upload Operation (Cont'd.) The Load Device wizard will close when the upload is completed if that option is selected. 31 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources When the upload is complete: The uploaded file is displayed in the tool with the file name upload.caf. You may then select Save or Save As from the File menu to keep a copy of the uploaded file. System information about the uploaded file is displayed in the Status bar. Uploading and Downloading a Single Controller Upload Operation (Cont'd.) 32 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources If the uploaded file was created with an older version of the tool, you will be prompted to upgrade the system or switch to the release (if 10.0 or greater). Select as appropriate for your needs. If you select Upgrade: Standard Modules listed will be upgraded. Any User Modified Modules will not be upgraded. If you select switch: Controller Tool will switch to the release of the upload. If you select open Read Only You will not be able to make changes to the file. Uploading and Downloading a Single Controller Upload Operation (Cont'd.) 33 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Uploading and Downloading a Single Controller Upload Operation Let’s see this in action Video: Upload a controller 34 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources When the load type selected is Download To Device, after you click Next on the Device Selection screen, the Load Summary page appears. Compare Controller and Tool code versions. Boot and Main code are automatically selected if the file was upgraded. Uploading and Downloading a Single Controller Download Operation Controller Tool 35 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Select the load operations to be performed and click the Finish button to initiate the download. Normally, you would use the default settings. Uploading and Downloading a Single Controller Download Operation (Cont'd.) The fault LED on the controller indicates the controller status during downloads: Boot – Light should be blinking. Main – Light should be On solid. Application – Light is On solid, followed by blinking as the download finishes, then goes off. 36 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Progress is indicated as the download proceeds. When the Download Operation is complete, the Load Device wizard will close if that option was selected. Uploading and Downloading a Single Controller Download Operation (Cont'd.) The fault LED on the controller indicates the controller status during downloads: Boot – Light should be blinking. Main – Light should be On solid. Application – Light is On solid, followed by blinking as the download finishes, then goes off. 37 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Uploading and Downloading a Single Controller Download Operation Watch how this works Video: Downloading a single controller 38 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources When downloading a controller as an N2 replacement device, there are additional considerations and the steps are slightly different. You must connect directly to the SA port of a compatible controller via the BTCVT (other connection types can not be used). The CAF file must be properly configured for N2 compatibility. Boot and Main code must be loaded first. Select the option to Switch Communication Mode before application code can be downloaded. Uploading and Downloading a Single Controller Download as N2 Controller Note: Refer to JCI LIT-12012005 - Modernization guide for N2 controllers for more information 39 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Make sure you connect directly to the SA port of the controller with a BTCVT. Uploading and Downloading a Single Controller Download as N2 Controller (Cont’d.) Note: In this example, the controller code will also be upgraded. Communication mode before download. 40 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Make sure you connect directly to the SA port of the controller with a BTCVT. Uploading and Downloading a Single Controller Download as N2 Controller (Cont’d.) Communication mode after download. 41 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Check Your Knowledge Please vote in the WebEx Poll panel When the Load Type; Download To Device is selected, what screen appears next after you click Next? a. System Upgrade Notification b. Device Selection Screen c. Load Summary Screen d. Load Device Wizard42 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources If you are downloading N2 compatible controllers, you must use the SA bus. In addition, with the Load Wizard, the Main code initially downloads as MS/TP (Wired Field Bus), but switches to N2 (N2 Slave Field Bus) when you select the Switch Communication Mode check box on the Load Summary screen. If the communication protocol in the controller does not match the protocol that is used in the application, you must switch communication modes before you download an application. When you upgrade field controllers with I/O Module devices on the SA Bus, you may need to upgrade certain devices to the latest release before you download the application. If this workflow is required, an alert appears that indicates which device requires an upgrade. For some devices, regardless of the download code order you choose, a message appears prompting you to install the Boot code before applying the Main code. The upgrade process does not proceed unless you perform this action. Uploading and Downloading a Single Controller Additional Notes Keep in mind the following when downloading a device: 43 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Keep in mind the following when downloading a device: If you are downloading devices over the Sensor/Actuator (SA) Bus, first download the individual device to which you are connected and then download the remaining devices. If you need to load Main code into an I/O Module device on the SA Bus, it is one to two minutes (30%) faster per I/O Module devices if you are directly connected to the SA Bus with a Bluetooth® connection. The typical download time is 3-1/2 minutes for an SA Bus download and nearly 5 minutes for an FC Bus connection. Uploading and Downloading a Single Controller Additional Notes on Downloading a Device (Cont'd.) 44 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Uploading and Downloading a Single Controller Additional Notes on Downloading a Device (Cont'd.) Important: The Tool detects and downloads ZFR1811/FX-ZFR1811 radio code even when the field controller Main and Boot code match the tool versions but the Radio code version does not match. The tool detects the versions of the Boot, Main, and Radio code versions in the field controller if you attempt to download an application. If the Boot or Main code version in the controller does not match the software version, the tool selects the Boot or Main check box. The Radio code is downloaded with the Main code. However, if the Boot and Main code versions in the tool match the code in the field controller but the Radio code version does not, the tool does not automatically select the Boot code and Main code check boxes. If the Main code check box is not selected, the Radio code is not downloaded. Keep in mind the following when downloading a device: When downloading a ZFR Wireless Field Bus Coordinator, follow the procedure in this section; however, you do not need to open an application before discovering the coordinator. When downloading ZFR Wireless Field Bus Routers, refer to the ZFR Wireless Field Bus Router product documentation for guidelines. If a ZFR1810 Coordinator has Main code version earlier than Release 5.0, it should be upgraded. 45 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Get ready to actively participate 46 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Lab Instructions 1. Scroll to the Downloading and Uploading a Single Controller Lab in the Learner’s Guide. 2. Follow the step-by-step instructions provided in the lab. 3. After completing the lab be prepared to discuss the results. Time : 30 Minutes 47 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Downloading and Uploading a Single Controller Lab Activity 1 Download a Controller via the Bluetooth® Interface Activity 2 Upload a Controller via the Bluetooth® Interface Session Overview This session consists of a PowerPoint presentation for downloading a controller using CCT, some demonstrations, and a lab to reinforce concepts from the demonstration. Objective After completion of this lab, you will be able to: • Download an FEC controller using the Bluetooth® interface. Contents 48 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Requirements 1. Laptop computer with CCT software 2. Wireless Commissioning Converter (BTCVT) 3. An FC bus with MS/TP controllers connected to it. If you have the FEC test panel, configure it so you can see all of the controllers on the FC bus. If not, connect as many controllers together on an FC bus so you can work with as many as possible. Please verify that each controller is set to a different device address. Downloading a controller takes a program from the computer you are working on and loads it into a controller. The program is stored in the controller’s flash memory. Downloading and Uploading an FEC Controller 49 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources How do I do it? Helpful Hints and Notes: 1. Ensure that your computer is Bluetooth® ready from the earlier lab. 2. Double-click the CCT icon on your desktop. 3. Connect the BTCVT to an available jack on a controller in the network. 4. Open the program you wish to download from the CCT main screen by selecting File > Open. 5. If the file requires an upgrade when it is opened, accept the upgrade and click File > Save. 6. Confirm the address of the controller by clicking Define Hardware. Click the Network Settings tab. If you are not sure, refer to the Bluetooth® wireless lab, or consult LIT-12011038. This is the CCT icon For our lab, connect to the SA/FC bus jack on the face of the IOM2710-0 controller. If the controller is not operational, consult the Controller Information lab, and find and flip the SA/FC switch to FC. For this lab, use the program labeled Fan Coil.caf that you downloaded prior to the beginning of the class. CCT version changes require controller file upgrades. If you are upgrading from 10.0 or 10.1 to 10.2 upgrade the file, do not switch the revision level to the older revision. The device address must match the switch settings on the FEC controller. Activity #1: Download a Controller via the Bluetooth® Interface 50 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing.Save GREEN. Excellence in Training Online Product Literature Resources Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources How do I do it? Helpful Hints and Notes: 7. If necessary, change the address to 5, and click Close to save the file again. 8. Click the Load button. 9. Select a connection type of Bluetooth® and make sure your Bluetooth® serial port is entered 10.Select the Download to Device radio button and click Next. 11.On the Device Selection screen, click the controller you wish to download, and then click Next. Selecting Download places the program from your computer in the controller. Choosing Upload brings the program from the controller to the computer. For our lab, select the controller at address 5. It should show up with a local display at address 3. The display is on the SA (sub) bus. If this controller does not show up, check the address switches on the controller. You might also confirm that the switch settings on the FEC are set to 5. The first and third switches should be on and all other switches should be off. 51 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources How do I do it? Helpful Hints and Notes: 12.On the Load Summary screen, compare the Main Code and Boot Code versions in the controller with the one on the computer. If they are the same, click the Application box, and then click Finish. If they are different, click the boxes next to Main, Boot, and Application, and then click Finish. 13.Click Tools > Controller Information. The principles from the Controller Information lab can be used to confirm that the code you just loaded into the FEC is operational in controller 5. Your equipment should already have the correct Main Code. You can select the Main Code download to see how it works. You may have to download Main and Boot code in some devices. Normally, CCT will automatically select the appropriate download check boxes. 52 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Activity #2: Upload a Controller via the Bluetooth® Interface How do I do it? Helpful Hints and Notes: 1. Ensure that your computer is Bluetooth® ready. 2. Double-click the CCT icon on your desktop. 3. Connect the BTCVT to an available jack on a controller in the network. 4. Click the Load button. 5. Ensure the Bluetooth® is selected and the correct serial port is entered 6. Select the radio button for load type Upload, and then click Next. 7. After the discovery is complete, click the controller you wish to upload, and then click Next. If you are not sure, refer to the Bluetooth® wireless lab, or consult LIT-12011038. For our lab, connect to the SA/FC bus jack on the face of the IOM2710-0 controller. Upload brings the program from the controller to the computer. The program will examine the bus and give you a list of all controllers that might be uploaded. This is the CCT icon. For our lab, select the controller at address 5. 53 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources How do I do it? Helpful Hints and Notes: 8. On the Load Summary screen, click Finish. There will be a bar progressing across the bottom of your screen as the upload progresses. The Load Device wizard will close automatically if “Close wizard after successful upload” is selected. If it is not selected, click Done to close the wizard. Your upload is now finished. At this point, you could save the program by selecting File > Save or Save As to place the program in the CCT project directory. You have successfully completed this lab. 54 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Discussion 55 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources To upload a single controller the target devices and addresses are identified. Function settings need to be loaded and connection parameters selected based on the connection type. Only the devices that are on the MS/TP trunk are displayed on the Device Selection Page and only devices that have the address of the loaded controller file can be downloaded. Uploaded files are displayed as upload.caf and system information about the uploaded file is displayed in the Status bar. There are additional requirements for downloading a controllers as an N2 replacement Module One: Uploading and Downloading a Single Controller (Key points) 56 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Module Two: Uploading and Downloading Multiple Controllers 57 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Module Objectives Download .caf and attributes to multiple controllers of the same type. Connect to a controller and define read and write attributes. Save and load saved attributes. Upload and download multiple controllers and attributes. Upload a network. 58 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Module Two: Uploading and Downloading Multiple Controllers Time : 60 Minutes Trunk Utilities Menu Lab: Uploading and Downloading Multiple Controllers Download to Same Controller Type Download to Multiple Different Controllers Upload Multiple Controllers 59 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Uploading and Downloading Multiple Controllers Trunk Utilities Menu There are different functions available depending upon whether or not there is a CAF file open. File Open No File Open 60 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Uploading and Downloading Multiple Controllers Download to Same Controller Type To download the same CAF file to multiple controllers of the same type: Start with the relevant file opened in the tool. Select Tools > Trunk Utilities > Download CAF & Attributes. Select the connection type and click Next. When Connected, click Discovery to view the controllers on the trunk. 61 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product LiteratureResources Continue by selecting the desired devices. The controllers that are to be downloaded, must be of the same type, e.g., select multiple VAV controllers. Uploading and Downloading Multiple Controllers with the Tool: Download to Same Controller Type (Cont'd.) 62 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources If needed, attributes may be selected, read, and written to the selected controllers. Click Next to skip this step and proceed to downloading controllers. Uploading and Downloading Multiple Controllers with the Tool: Download to Same Controller Type (Cont'd.) Select Object/Parameter and attribute, then click OK. 63 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources If needed, attributes may be selected, read, and written to the selected controllers. Click Next to skip this step and proceed to downloading controllers. Reading and Writing attributes are much faster than a full upload or download. Different values may be written to each selected controller for a particular attribute. The list of attributes and selected controllers may be saved and reused later. Uploading and Downloading Multiple Controllers with the Tool: Download to Same Controller Type (Cont'd.) 64 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Select the controllers to download. Click Finish to proceed. If needed, Boot and Main Code may also be downloaded. A download template containing the list of controllers can be saved/reused. Uploading and Downloading Multiple Controllers with the Tool: Download to Same Controller Type (Cont'd.) Note: If you are connected to the bus through a controller, that controller should be upgraded first by itself before upgrading and downloading other controllers. 65 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Progress is indicated as each controller is downloaded. Uploading and Downloading Multiple Controllers with the Tool: Download to Same Controller Type (Cont'd.) 66 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Status is reported as the downloads are completed. Status for selected controllers may be viewed. A log of controllers downloaded may also be viewed and/or cleared. Either may be copied to the clipboard for inclusion in other project documentation. Uploading and Downloading Multiple Controllers with the Tool Download to Same Controller Type (Cont'd.) 67 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Uploading and Downloading Multiple Controllers Download to Multiple Different Controllers You can use the tool to download multiple different controllers with different applications, all in one download session. Start the tool with no file open or, close any CAF file you may be working with. Select Tools > Trunk Utilities > Download Multiple CAFs. Select the connection type. Discover the controllers. Optionally, you may open a previously saved download template. Select desired controllers, CAF, and parameter files. Optionally, assign names to each controller. Controller Boot and Main Code may also be upgraded. You may also save your list for later use as a Download template. Select Finish to download all the CAF files with a single command. 68 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Let’s take a look. Uploading and Downloading Multiple Controllers with the Tool Download to Multiple Different Controllers (Cont'd.) Video: Downloading multiple controllers from one caf 69 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources After selecting the connection type, click Discovery to view the connected controllers. Optionally, you may save or browse for and select a previously saved Download template. If you chose this option, use the Get Device Info button to verify controller code versions. Uploading and Downloading Multiple Controllers with the Tool Download to Multiple Different Controllers (Cont'd.) 70 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Select the desired controllers for download. Browse and select .caf and (optionally) attribute files for each selected controller. You can also assign names and BACnet® IDs to each controller (optional). Attribute templates are not required. Uploading and Downloading Multiple Controllers with the Tool Download to Multiple Different Controllers (Cont'd.) 71 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Boot and/or Main Code may also be downloaded to upgrade controllers. If you are connected to a controller on the SA bus via Bluetooth®, be sure to download that controller individually first to help prevent download errors. Uploading and Downloading Multiple Controllers with the Tool Download to Multiple Different Controllers (Cont'd.) 72 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Click Finish to begin the download of the selected controllers and attributes. Uploading and Downloading Multiple Controllers with the Tool Download to Multiple Different Controllers (Cont'd.) 73 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources The status and progress of the download is displayed as it proceeds. Uploading and Downloading Multiple Controllers with the Tool Download to Multiple Different Controllers (Cont'd.) 74 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources You can save the list of controllers in a Download template for later use. Status for selected controllers may be viewed. A log of controllers downloaded may also be viewed and/or cleared. Either may be copied to the clipboard for inclusion in other project documentation. Uploading and Downloading Multiple Controllers with the Tool Download to Multiple Different Controllers (Cont'd.) 75 Co py rig ht 20 16 by Jo hn so n C on tro ls, In cUploading and Downloading Multiple Controllers with the Tool Download to Multiple Different Controllers Let’s take a look. Video: Download multiple controllers with multiple CAF files 76 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Uploading and Downloading Multiple Controllers Upload Multiple Controllers This allows you to simply upload the controller application files (.caf ) from multiple controllers on the same FC bus in one session. Start the tool with no file opened. Select Tools > Trunk Utilities > Upload Multiple CAFs. Select the connection type. Specify the directory where you want the controller application files to be uploaded. Click the Discovery button to find and then select different controllers. Optionally, you may use a previously saved Download template to list the controllers. Select Finish to upload the CAF files from selected controllers with a single command. Files are stored in the directory, selected, and named from the system name of the controller, followed by an underscore, then the controller address number. For example: Fan Coil_35.caf System Name from Controller An Underscore Controller Switch Address Number 77 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources After connecting, click Select Directory to choose an appropriate location to save the uploaded files. Then, click Discovery to locate the controllers on the FC bus. Optionally, you may browse for and open a previously saved Download template for the list of controllers to be uploaded. Select the controllers to upload. Click Finish to start the upload. Uploading and Downloading Multiple Controllers with the Tool Upload Multiple Controllers (Cont’d.) 78 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Progress is reported as the uploads proceed. When it is finished, you may perform any of the following: Save the list of controllers to a Download template for later use. Status for selected controllers may be viewed. A log of controllers uploaded may also be viewed and/or cleared. Either may be copied to the clipboard for inclusion in other project documentation. Uploading and Downloading Multiple Controllers with the Tool Upload Multiple Controllers (Cont’d.) 79 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources This feature allows you to update the boot and radio code for selected ZFR wireless devices. It is only available with no .caf file open. From the Tools menu, select Trunk Utilities > Download ZFR. The Trunk Utilities - Download ZFR wizard appears with the Connection screen active. Pick your connection type, and then click Next. Trunk Utilities Download ZFR 80 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources When the Download screen indicates that you are connected, you can click Discovery to find devices. After devices are listed, you can select the ones you wish to upgrade. Boot and Main code can be forced to be downloaded. Click Finish to perform the upgrade and view the progress of the download for the selected devices. Trunk Utilities Download ZFR (Cont’d.) 81 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources The Read/Write Attributes Online utility allows you to mass edit the attributes of online controllers using attribute templates and read/write functionality. You can access this utility from the Tools menu by selecting Trunk Utilities > Read/Write Attributes Online. This utility has the same Connection and Device Selection screens as the Load Device wizard. Trunk Utilities Read/Write Attributes Online Note: When a .caf file is not loaded, you cannot add attributes. You may only remove attributes or add, delete, or modify the devices as well as save the template. 82 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Devices may be discovered or added manually. Only selected devices will be read/written to. Trunk Utilities Read/Write Attributes Online (Cont'd.) Note: The Device Name and Instance Number are only written during the download process. These values cannot be written during a read/write operation. The Instance Number can be assigned or calculated automatically by right- clicking on that column. 83 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Attributes are added by clicking the column. Select the object and desired attribute from the tree view. By default, only BACnet® exposed items are displayed. The Show All option allows other attributes to be selected. Trunk Utilities Read/Write Attributes Online (Cont'd.) 84 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Attributes templates may be saved and opened again for later use. Device Name and selected attribute values may be read, modified, and written for the selected controllers. Trunk Utilities Read/Write Attributes Online (Cont'd.) 85 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Be sure to save the changes to an Attribute Template if you want to use it later. Device Name and Instance Number may only be modified by downloading the controller. These may be assigned and/or calculated automatically by right- clicking the column. Selected attribute values initially come from the .caf file. But these may be read, modified, and written for the selected controllers. Trunk Utilities Read/Write Attributes Online (Cont'd.) 86 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources The Manage Attribute Templates feature allows you to create or modify these templates without connecting to controllers to changes to the controllers. Trunk Utilities Manage Attribute Templates Note: When a .caf file is not loaded, you cannot add attributes. You may only remove attributes, and add, delete, or modify the list of devices. 87 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources The Upgrade Multiple Controllers trunk utility allows youto upgrade .caf files from multiple devices on the same trunk. You can access this utility from the Tools menu by selecting Trunk Utilities > Upgrade Multiple Controllers. This menu option is only available when a .caf file is not open. It is not recommended to use Ethernet pass-through connection for upgrading multiple controllers due to potential communications loss during the process. It is recommended that you upgrade one device first, before upgrading an entire trunk. Trunk Utilities Upgrade Multiple Controllers 88 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources When multiple controllers are selected to upgrade, each will go through the following steps: An upload of the application An upgrade of the .caf, if needed A download of Boot and/or Main code, if needed A download of the upgraded .caf file, if needed Status is updated for each step as it progresses. You may use the View Log and View Status as well to monitor the progress. Trunk Utilities Upgrade Multiple Controllers (Cont’d.) Note: An I/O Module Device on the SA bus of a controller must be upgraded before the controller can be upgraded. 89 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources If present, pay careful attention to the caution for wireless devices. Click Finish to begin the process for the selected controllers. Trunk Utilities Upgrade Multiple Controllers (Cont’d.) Save the list of controllers. Browse for and open a previously saved list. Use the Discovery button to find the controllers on a trunk. Selected controllers 90 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Uploading and Downloading Multiple Controllers with the Tool Upload Multiple Controllers Let’s see how this works. Video : Upload Multiple Controllers 91 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Module Two: Uploading and Downloading Multiple Controllers (Key points) There are different functions available in the Trunk Utilities Menu depending on whether or not there is a .caf file open. The same .caf file can be downloaded to multiple controllers. The tool can also be used to download multiple different controllers with different applications, all in one download session. The controller application files (.caf ) from multiple controllers may also be uploaded on the same FC bus in one session. Progress and status can be reviewed during a download or upload process. 92 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Get ready to actively participate 93 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Lab Instructions 1. Scroll to the Downloading and Uploading Multiple Controllers Lab in the Learner’s Guide. 2. Follow the step-by-step instructions provided in the lab. 3. After completing the lab be prepared to discuss the results. Time : 60 Minutes 94 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Activity 1 Downloading and Uploading Multiple Controllers with CCT Activity 2 Downloading and Uploading Attributes with CCT Activity 3 Download many controller with CCT Activity 4 Upload Many Controllers with CCT Session Overview This session consists of a lab to reinforce concepts from the instructor-led course content. Contents Downloading and Uploading Multiple Controllers Lab 95 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Activity #1: Downloading and Uploading Multiple Controllers with CCT Requirements • Laptop computer with CCT software. • Wireless Commissioning Converter (BTCVT). • An FC bus with MS/TP controllers connected to it. If you have the FEC test panel, configure it so you can see all of the controllers on the FC bus. If not, connect as many controllers together on an FC bus so you can work with as many as possible. Please verify that each controller is set to a different device address. Estimated Time This exercise takes about 60 minutes to complete. Download Multiple Controllers and Attributes Using the Same .caf File How do I do it? Helpful Hints and Notes: 1. Ensure that your computer is Bluetooth® ready. 2. Double-click the CCT icon on your desktop. 3. Connect the BTCVT to an available jack on a controller in the network. If unsure, refer to the Bluetooth® Wireless lab, or consult LIT-12011038. This is the CCT icon. For our lab, connect to the SA bus jack on the FEC controller. 96 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources How do I do it? Helpful Hints and Notes: 4. Open the pre-built fan coil file. 5. Click Tools > Trunk Utilities > Download CAF & Attributes 6. Select the radio button for Bluetooth® and make sure that the Bluetooth® COM port is the same that you wrote down earlier. Click Next. 7. Wait while the connection is made and then click the Discovery button. 8. After discovery is complete, clear the controllers you do not want to update. 9. Type in the instance number to download to the device and change its name, if needed. In this case, use an instance of 5005 and device name as fan coil. For our class, use Fan Coil.caf. The pre-built fan coil file was downloaded from the class support site You should only select a controller or controllers that can handle the file you have opened, that is, FEC controllers that will be serving a fan coil system. The instance number is a unique number identifying the controller to BACnet®. 97 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources How do I do it? Helpful Hints and Notes: 10.Select the Click To Define New Attribute column header. 11.From the list of BACnet® exposed objects, scroll down to Logic > Setpoint/Miscellaneous > ZN-T Setpoint Determination, and select CLGOCC-SP. On the right hand side, select Default Value. 12.Click OK. 13.Change the default value to 76. This will open the Select Attribute window. Attributes are internal controller values that might normally show up on the Parameters tab in CCT. We will only download one controllerin this example, but you can load the same CAF file simultaneously to many controllers that have the same function and are on the same trunk. 98 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources How do I do it? Helpful Hints and Notes: 14.Select the Click To Define New Attribute column header again. This time select HTGOCC-SP from the same ZN-T setpoint determination block. On the right hand side, select Default Value. 15.Define a new column and select ZNT-SP from Network inputs. 16.Define a new column and select EFFCLG-SP from ZN- T Setpoint Determination. Your screen will look similar to this: 17.Click Save at the top of the screen, using a name of Fan Coil Attribute template and save it to the desktop. 18.Clear ZNT-SP and EFFCLG-SP. Change this default value to 72. Select Present Value as the data type on this one. Select Present Value for this one. This allows you to reuse the template. In your system, you might want to create an Attribute directory for your particular job. You cannot download these values. You will get a message, telling you this, on the next screen. 99 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources How do I do it? Helpful Hints and Notes: 19. In the column below Selected, select the controllers you want to update. 20.Click Next > Finish to complete the download. 21. Watch the download action in the Status column. 22.Click Cancel. 23.After completion, select Trunk Utilities > Read/Write Attributes Online, and then select the fan coil. Click Next, and then click the Browse button, and load the Fan Coil Attribute template. 24.Make sure everything is selected. Click Read Attributes. If you download multiple controllers, all the attributes could be different. This would be useful especially with the VAV controllers. You can click (and refresh) the View Status button to see details about the download. 100 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources How do I do it? Helpful Hints and Notes: Leave Selected checked. In this case, clear Htg, Clg, and effective setpoints. If you thought, “The Effective Setpoint is determined by the occupied heating and cooling setpoints and is adjusted by the network setpoints,” then you were right. 25.What i s the valu e of ZNT-SP? __________________________________________ What i s the valu e of EFFCLG-SP? __________________________________________ 26.Clea r everything except ZNT-SP. 27.Mak e ZNT-S P equal t o 7 6 and click Writ e Attributes. Clic k OK. 28.Select everythin g again, an d clic k Rea d Attributes. 29.Now, what i s th e valu e of EFFCLG-SP? __________________________________________ 30.Wh y d o yo u think thi s happened? __________________________________________ 101 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources How do I do it? Helpful Hints and Notes: 31.Select Click to Define New Attribute > Hardware > Inputs > ZN-T, and select Present Value. Click OK. 32. Click Read Attributes. 33.Save the attribute file. 34.Click Finish. You will notice that ZN-T reads 0. There is a problem with the program that we will fix and then return to trunk utilities. 102 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Activity #2: Downloading and Uploading Attributes with CCT How do I do it? Helpful Hints and Notes: 1. Ensure that your computer is Bluetooth® ready. 2. Double-click the CCT icon on your desktop. 3. Connect the BTCVT to an available jack on a controller in the network. 4. Do not open a CAF file. If one is already opened, click File > Close. 5. Click Tools > Trunk Utilities > Read/Write Attributes Online. 6. Select the radio button for Bluetooth® and make sure your Bluetooth® COM port is the same that you wrote down earlier. Click Next. 7. Wait to verify connection, and then click Discovery. If unsure, refer to the Bluetooth® Wireless lab, or consult LIT-12011038. This is the CCT icon. For our lab, connect to the SA bus jack on the FEC controller. When you read and write attributes, all controllers that are selected, need to have the same attributes in their program. In this case, select the fan coil you have been working with. 103 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources How do I do it? Helpful Hints and Notes: 8. Click Browse, locate the file you saved on the desktop called Fan Coil Attribute template, and then click Open. This is a file that can be transferred from one computer to the other as well. Q1) What are the occupied cooling and heating setpoint defaults for fan coil? Using Help, answer the following questions: Heating _______________________________________________________________________________________ Cooling _______________________________________________________________________________________ How do I do it? Helpful Hints and Notes: 9. Click Read Attributes. This quickly gets the values from the controllers and places them in memory. If they have been changed, you will see the change reflected here. 104 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Q2) Did the values you read agree with the default values? How do I do it? Helpful Hints and Notes: 10.Change the setpoints to 75 and 71, respectively. Clear all except CLGOCC-SP and HTGOCC-SP, and then click Write Attributes. 11.Change the setpoints to 76 and 72, and click Read Attributes. You should receive a write successful message. Q3) Did the values go back to 75 and 71? 105 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources How do Ido it? Helpful Hints and Notes: 12.Click Finish to complete the attribute read/write process. 106 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Activity #3: Download many controllers with CCT Download Many Controllers via the Bluetooth® Interface How do I do it? Helpful Hints and Notes: 1. Ensure that your computer is Bluetooth® ready. 2. Double-click the CCT icon on your desktop. 3. Connect the BTCVT to an available jack on a controller in the network. 4. Do not open a CAF file. If one is already open, click File > Close. 5. Click Tools > Trunk Utilities > Download Multiple Controllers. 6. Select the radio button for Bluetooth® and make sure your Bluetooth® COM port is the same that you wrote down earlier. Click Next. If unsure, refer to the Bluetooth® Wireless lab or consult LIT-12011038. This is the CCT icon. For our lab, connect to the SA bus jack on the FEC controller. 107 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources How do I do it? Helpful Hints and Notes: 7. After the connection is established, click Discovery. Next, select the FEC and VMA devices by selecting the box next to the Discovered column. 8. Under application for the fan coil, click the Browse button, and find the Fan Coil.caf file you have been using. 9. For the VMA controller, use the VAV Box.caf file in your class directory. 10.Click Save in the upper right part of this dialog box and use the name as Multiple Controllers Job 1. 11.Click Finish to complete the download. Only FEC, VMA, and FAC controllers are selected by default when the discovery screen comes up. Third party nodes are automatically cleared. This allows you to selectively download controllers. You can use the same CAF file for all similar controllers. Change the name, device address, and BACnet® instance number, as appropriate, for each controller. The template can be transferred between computers. Use the View Status button to see how the download is going. Refresh updates the status. 108 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Activity #4: Upload Many Controllers with CCT Upload Many Controllers via the Bluetooth® Interface How do I do it? Helpful Hints and Notes: 1. Ensure that your computer is Bluetooth® ready. 2. Double-click the CCT icon on your desktop. 3. Connect the BTCVT to an available jack on a controller in the network. 4. Do not open a CAF file. If one is already open, click File > Close. 5. Click Tools > Trunk Utilities > Upload Multiple Controllers. 6. Select the radio button for Bluetooth® and make sure your Bluetooth® COM port is the same that you wrote down earlier. Click Next. If unsure, refer to the Bluetooth® Wireless lab or consult LIT-12011038. This is the CCT icon. For our lab, connect to the SA bus jack on the FEC controller. 109 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources How do I do it? Helpful Hints and Notes: 7. After the connection is established, click Select Directory. 8. On the Controller Upload screen, click Discovery. When completed, select all the controllers except TEC by selecting the box next to the Discovered column. Click Finish. 9. Click Finish to upload the controllers. 10. Select Done when complete. Use the desktop to save these files. Use the View Status button to see how the upload is going. Refresh updates the status. You have completed this lab. 110 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Discussion 111 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Module Three: Troubleshooting Software Connections 112 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Module Objectives Perform an analysis of some of the software modules (using the Help and other tools such as View Connections, View Logic, Simulator, etc.), given a simple commisioning tool standard system configuration. Perform an analysis of State-based Control. 113 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Module Three: Troubleshooting Software Connections Time : 25 Minutes Commissioning Data Flow View Connections State Based Control 114 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Usually, the data flows from left to right in Commissioning applications. Inputs are typically connected to and evaluated by modules in the Setpoint/Miscellaneous column. Setpoint/Miscellaneous outputs flow into State Generation modules, where the modes or states of the different subsystems are determined. State Generation outputs flow into the State Table. State Tables pass values to Output Control modules. Output Control modules pass signals to the Outputs themselves. Input Values Setpoint/Miscellaneous Values State Generation Setpoint/Miscellaneous State State Generation State Tables State Tables Mode Output Control Values Outputs Output Control Troubleshooting Software Connections Commissioning Data Flow 115 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources LV Blocks cause the data to flow from right to left in Commissioning applications. State Generation modules often need a lockout value from an output controller. Output Control modules pass signals to the LV Blocks, which are then passed back to the State Generator modules. LV Blocks are always used when the result of a process is fed back into a process. Data Flow in the Commissioning Programs (Cont'd.) State State Generation State Tables.. State Tables.. Mode Output Control Values LV Block Output Control Note: At revision 6.0 or higher, LV blocks can be hidden. 116 Co py rig ht 20 16 by Jo hn so n C on tro ls, In c Our Policy prohibits printing. Save GREEN. Excellence in Training Online Product Literature Resources Select the ZNT-SP network input followed by the Connections tab in the Features panel. Note that the output of the ZNT-SP network input is connected to the Network
Compartilhar