20-25 Magnetic Anisotropy 20.22 This problem asks for us to estimate saturation values of H for single crystal nickel in the [100], [110], and [111] directions. All we need do is read values of H at points A, B, and C on the curves shown in Figure 20.17. Saturation in the [111] direction (point A) is approximately 3000 A/m. Corresponding values in [110] and [111] directions are approximately 15,000 and 17,500 A/m, respectively. Excerpts from this work may be reproduced by instructors for distribution on a not-for-profit basis for testing or instructional purposes only to students enrolled in courses for which the textbook has been adopted. Any other reproduction or translation of this work beyond that permitted by Sections 107 or 108 of the 1976 United States Copyright Act without the permission of the copyright owner is unlawful.