Text Material Preview
c) d) View Answer Answer: a Explanation: When referred to primary, secondary inductance winding will be turns ratio squared. 13. Consider a 10 KVA, 2000/200 V, single phase transformer having below following parameters: r1=10Ω, r2=0.1Ω, l1= 40mH, l2=0.4 mH, M = 10H. Then the expected primary self inductance will be a) 100.04H b) 99.06H c) 1.0004H d) 10.04H View Answer Answer: a Explanation: Primary self inductance = L1 = Lm1 + l1 = (N1/N2)*M + l1 = 2000/200*10 + 0.04 =100.04 H. 14. There is a 10 KVA, 2000/200 V, single phase transformer having below following parameters: r1=10Ω, r2=0.1Ω, l1= 40mH, l2=0.4 mH, M = 10H. Then the expected secondary self inductance will be a) 100.04H b) 99.06H c) 1.0004H d) 10.04H http://www.sanfoundry.com/wp-content/uploads/2017/05/electrical-machines-questions-answers-transformer-as-magnetically-coupled-circuit-q12c.png http://www.sanfoundry.com/wp-content/uploads/2017/05/electrical-machines-questions-answers-transformer-as-magnetically-coupled-circuit-q12c.png http://www.sanfoundry.com/wp-content/uploads/2017/05/electrical-machines-questions-answers-transformer-as-magnetically-coupled-circuit-q12c.png http://www.sanfoundry.com/wp-content/uploads/2017/05/electrical-machines-questions-answers-transformer-as-magnetically-coupled-circuit-q12d.png http://www.sanfoundry.com/wp-content/uploads/2017/05/electrical-machines-questions-answers-transformer-as-magnetically-coupled-circuit-q12d.png http://www.sanfoundry.com/wp-content/uploads/2017/05/electrical-machines-questions-answers-transformer-as-magnetically-coupled-circuit-q12d.png