Prévia do material em texto
Int. J. Oral Maxillofac. Surg. 2022; 51: 1345–1354 https://doi.org/10.1016/j.ijom.2022.03.057, available online at https://www.sciencedirect.com Meta Analysis Dental Implants Long-term clinical outcomes of immediate loading versus non-immediate loading in single-implant restorations: a systematic review and meta-analysis G. Zhao, Y. Zhou, S. Shi, X. Liu, S. Zhang, Y. Song: Long-term clinical outcomes of immediate loading versus non-immediate loading in single-implant restorations: a systematic review and meta-analysis. Int. J. Oral Maxillofac. Surg. 2022; 51: 1345–1354. © 2022 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved. Abstract. Dental implant restoration is a predictable treatment option for replacing missing or damaged teeth. Conventional loading requires a prolonged treatment period and second surgical interventions. The aim of this study was to compare the clinical outcomes between immediate and non-immediate (early or conventional) loading in single-implant restorations. A literature search of the PubMed, Embase, Cochrane Library, Web of Science, and ClinicalTrials.gov databases was performed in January 2020. Only randomized clinical trials (RCTs) were included. The overall risk ratios (RRs), mean differences (MDs), and 95% confidence intervals (CIs) were used in the analyses. A total of 10 RCTs reporting on 423 patients were included. There was no significant difference in any of the outcomes of interest between the immediate and non-immediate loading cases: implant failure at the patient level (RR 1.29, 95% CI 0.35 to 4.78, P = 0.71), implant failure at the implant level (RR 1.19, 95% CI 0.40 to 3.51, P = 0.75), marginal bone loss (MD −0.04, 95% CI −0.16 to 0.08, P = 0.54). Subgroup analyses showed similar results. Immediate loading had predictable long-term clinical outcomes if the indicated patients were carefully selected. The influences of several technical factors need to be confirmed in additional clinical trials. G. Zhaoa, Y. Zhoub, S. Shia, X. Liua, S. Zhanga, Y. Songa aState Key Laboratory of Military Stomatology and National Clinical Research Center for Oral Diseases and Shaanxi Engineering Research Center for Dental Materials and Advanced Manufacture, Department of Oral Implantology, School of Stomatology, The Fourth Military Medical University, Shaanxi, PR China; bLintong Rehabilitation and Convalescent Center of PLA Joint Logistic Support Force, Huaqing Road No.26, Xi’an, China, 710600 Keywords: dental implants; single-tooth dental implants; immediate dental implant loading; dental restoration failure; randomized con- trolled trials as topic. Accepted for publication 23 March 2022 Available online 13 April 2022 0901-5027/511345 + 10 © 2022 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved. https://doi.org/10.1016/j.ijom.2022.03.057 https://doi.org/10.1016/j.ijom.2022.03.057 http://www.sciencedirect.com/science/journal/09015027 https://doi.org/10.1016/j.ijom.2022.03.057 Conventionally, a non-disturbed healing period of at least 3 months without any loading on the implants after implanta- tion surgery is needed to achieve com- plete and successful osseointegration. This loading protocol is termed ‘con- ventional loading’ (CL) or ‘delayed loading’.1–11 However, this traditional protocol requires a prolonged treatment period and an additional surgical inter- vention,3,8 and patients usually have a strong desire to obtain their prosthesis as soon as possible.2,12,13 ‘Early loading’ (EL), which is defined as implant loading at least 48 hours but no later than 3 months after implant surgery, can shorten the treatment period. However, patients still need a second surgery and have to endure tooth loss for several weeks.14,15 Therefore, the concept of ‘immediate loading’ (IL) has been proposed. IL, which is defined as a prosthetic restoration performed within 48 hours after the implantation proce- dure,6,13,15–20 provides the clinician with the possibility of further improving the effect of dental implantation.6,16–19 Compared with CL and EL, IL not only reduces the total treatment period and simplifies the surgical interventions but also protects the healing extraction socket and provides a platform to promote soft tissue healing, which contributes to aesthetics.16,21–25 Nu- merous clinical trials have suggested that IL is a practical and predictable treatment option when sufficient pri- mary stability of the implants can be achieved.9,14,17,19,26–36 Histological stu- dies have also suggested that IL on implants does not influence the os- seointegration process.37 Several sys- tematic reviews and meta-analyses have shown that IL has comparable clinical outcomes to non-immediate loading (non-IL, i.e. EL or CL) over short-term follow-up.15,20,38 Although IL has many advantages over non-IL, there is still controversy about this issue since some reviews have reported higher implant failure in IL cases compared with non-IL cases.20,39 Moreover, only a limited number of systematic reviews have re- ported long-term clinical outcomes of IL compared with non-IL in single- implant restorations. A recent review suggested that more than 21% of im- plant failures occur within 2 years of implant placement,40 which means that the analysis of the long-term results from IL implants requires a follow-up period of at least 2 years. The aim of this systematic review and meta-analysis was to compare the clinical and radiographic outcomes between IL and non-IL (EL or CL) in single-implant restorations using the indexes of the im- plant failure rate and marginal bone loss (MBL). Moreover, the influences of sev- eral technical factors were also in- vestigated, including the type of non-IL (EL or CL), implant location (maxilla or mandible), implant placement time (im- mediate or delayed implantation), loading concept (occlusal or non-occlusal contact), and prosthesis retention pattern (screw-retained or cement-retained). This study presents a more detailed and in- depth analysis to explore the influence of the different loading types (IL vs non-IL) on long-term clinical outcomes in single- implant restorations. Materials and methods The meta-analysis was performed based on the standard methodology outlined in the Cochrane Handbook and the findings are reported in ac- cordance with the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines.41 Search strategy The PICOS strategy was used to con- struct the research question, and the PICO question for this research in- cluded four aspect: P (patients or po- pulation), patients in need of a single tooth replacement; I (intervention), treatment with a dental implant (placed immediately, early, or late) with im- mediate prosthetic loading; C (com- parator or control group), compared with treatment with a dental implant (placed immediately, early, or late) with conventional prosthetic loading; O (outcomes), implant failure and MBL. The search strategies to allow repeat- ability of this study are provided in Supplementary Material Table S1. Screening of records and assessment of eligibility Two reviewers selected the studies in- dependently by screening the titles and abstracts of the search results according to the following inclusion criteria: (1) the study type was a randomized clinical trial (RCT); (2) participants were pa- tients with one or more missing teeth and undergoing IL or non-IL for single- implant restorations after implant placement; (3) a comparison between IL and non-IL was performed; (4) the duration of follow-up was at least 2 years; (5) outcomes included implant failure (at the patient and implant levels) and MBL; and (6) publication in English. The exclusion criteria were as follows: (1) articles with inadequateavailable data (implant failure or MBL); and (2) reviews, case reports or case series, letters or comments. In addition, there was no limitation on the location of the implants in this study (maxilla or mandible; anterior or posterior loca- tions). A third author resolved any dis- agreement between the two reviewers. A full-text assessment was performed for those studies that the authors con- sidered relevant and also those for which eligibility was uncertain; dis- agreements were resolved by further discussion or an additional author’s evaluation. Regarding agreement be- tween the reviewers, a kappa value be- tween 0.40 and 0.59 was considered fair agreement, a value between 0.60 and 0.74 was considered good agreement, and a value of 0.75 or more was considered excellent agreement. Dis- agreement regarding inclusion was re- solved by discussion. When multiple articles reported the same trial, the most recent one with complete data was included. Data extraction Data from the studies were extracted by two investigators independently. The re- corded data included general informa- tion (first author’s name, year of publication, and region of the study), study design (loading location, types of non-IL, duration of follow-up, and sample size), characteristics of the parti- cipants (sex and age), retention patterns of the prostheses, and clinical or radio- graphic outcomes (implant failure, MBL, etc.). In this study, implant failure was defined as the presence of any mobility, pain, infection, or implant loss during the observation period, and implant failure rates were assessed at the patient level (percentage of patients with implant failure among all of the patients) and implant level (percentage of failed im- plants among all of the implants). Quality assessment Two authors independently assessed the risk of bias in the included studies. The Cochrane Collaboration tool for 1346 Zhao et al. assessing risk of bias in randomized trials was used,42 which includes six domains: selection bias, performance bias, detection bias, attrition bias, re- porting bias, and other bias. Studies were classified as at low risk if all cri- teria were met, as at moderate risk if one criterion was not met, and as at high risk if two or more criteria were not met. A third author resolved any disagreement between the two re- viewers regarding the risk of bias as- sessment. GRADEpro was used to perform the certainty assessment of the included study outcomes. Statistical analysis The data were analysed using RevMan v.5.3 software (Cochrane Collaboration). The overall risk ratios (RRs) or mean differences (MDs) as well as the 95% confidence intervals (CIs) were calculated with a fixed-effects model (Mantel– Haenszel method) or random-effects model (DerSimonian–Laird method). For dichotomous outcomes (implant survival), the estimate of the effect of the intervention on the survival rate was presented as the RR with a 95% CI.15 For continuous outcomes (MBL), the estimate of the effect of the intervention was presented as the MD ± standard deviation with a 95% CI. The I2 statistic was used to present the heterogeneity of the studies: values ≤25% were classified as indicating low heterogeneity, values of 25–50% indicated moderate hetero- geneity, and values ≥50% indicated high heterogeneity.15 When significant het- erogeneity was found (I2 > 50%), the random-effects model was used to pool the data. Otherwise, the fixed-effects model was applied. In addition, subgroup analyses based on the type of non-IL (EL or CL), im- plant location (mandible or maxilla), implant placement time (immediate im- plant placement or delayed implant pla- cement), loading concept (occlusal contact or not), and type of prosthesis retention (screw-retained or cement-re- tained) were performed. A sensitivity analysis was conducted by omitting one study at a time to ex- amine the influence of individual stu- dies on the overall results. Publication bias was explored using Egger’s test, with P–d el ay ed 60 M ax ill a D el ay ed A es th et ic - Sc re w ed o r ce m en te d N o 31 31 62 62 (2 6/ 36 ) 39 .3 (1 8– 67 ) C an ni zz ar o, 20 12 49 Im m ed ia te –e ar ly 48 M an di bl e or m ax ill a D el ay ed M ol ar s - Sc re w ed Y es 29 31 60 30 (1 5/ 15 ) 35 (1 8– 57 ) P ro sp er , 20 10 45 Im m ed ia te –d el ay ed 60 M an di bl e Im m ed ia te M ol ar s C em en te d Y es 60 60 12 0 71 (3 5/ 36 ) 58 .3 (2 6– 72 ) D eg id i, 20 09 50 Im m ed ia te –d el ay ed 36 M an di bl e D el ay ed A es th et ic - Sc re w ed N o 30 30 60 60 (2 7/ 33 ) 31 .5 ± 1 1. 8 D on os , 20 19 1 Im m ed ia te –d el ay ed 60 M an di bl e or m ax ill a D el ay ed A es th et ic - Sc re w ed N o 10 14 24 24 49 .3 Sh ib ly , 2 01 043 Im m ed ia te –d el ay ed 24 M ax ill a Im m ed ia te A es th et ic D ef ec t so ck et s C em en te d N A 27 31 58 58 N A C hi da ga m , 20 17 48 Im m ed ia te –d el ay ed 72 M ax ill a D el ay ed M ol ar s - C em en te d N A 10 10 20 20 (1 4/ 6) 35 (1 9– 31 ) C re sp i, 20 08 47 Im m ed ia te –d el ay ed 24 M ax ill a Im m ed ia te A ll In ta ct so ck et s C em en te d Y es 20 20 40 40 (1 6/ 24 ) 47 .2 (2 4– 68 ) M el on i, 20 18 46 Im m ed ia te –d el ay ed 36 M ax ill a D el ay ed M ol ar s - Sc re w ed N o 20 20 40 20 (8 /1 2) 46 (2 8– 70 ) B öm ic ke , 20 17 44 Im m ed ia te –d el ay ed 36 M ax ill a D el ay ed P re m ol ar s an d m ol ar s - Sc re w ed N o 19 19 38 38 (1 6/ 22 ) 53 .3 (2 1. 4– 76 .2 6) IL , im m ed ia te l oa di ng ; E L , ea rl y lo ad in g; C L , co nv en ti on al l oa di ng ; M , m al e; F , fe m al e; N A , no t av ai la bl e. 1348 Zhao et al. analyses (Table 2). Most of the sub- group analyses showed high hetero- geneity, except those stratified by specific factors, including the subgroup analyses for mandible implant location (P = 0.18, I2 = 44%), implant placement time of delayed implant insertion (P = 0.52, I2 = 0%), screw-retained pros- thesis retention (P = 0.39, I2 = 3%), and loading concept of non-occlusal contact (P = 0.39, I2 = 3%). These results in- dicate that the implant placement time, type of prosthesis retention, and the loading concept may be factors that affect the results. In addition, the sen- sitivity analysis showed that none of the included studies had a high risk of bias; none of the included studies had a large effect on the pooled MD. Publication bias and assessment of the quality of evidence There was no significant publication bias, as evidenced by Egger’s test (P > 0.05). The GRADEpro results are shown in Supplementary Material Fig. S1; all of the outcomes analysed had high certainty. Discussion With the benefits of reducing the treatment period, avoiding a second surgical intervention, and better aes- thetic outcomes,16,22–25,30 IL has been a topic of interest for years. However, previous studies have demonstrated the continuing controversy regarding the clinical outcomes of IL, and only a limited number of meta-analyses have focused on long-term outcomes. This Fig. 2. Risk of bias summary. Fig. 3. Risk of bias graph. Immediate vs non-immediate single implant loading 1349 controversy prompted the present meta-analysis, which aimed to further investigate the predictability of IL compared with EL and CL in terms of long-term clinical outcomes and to ex- plore factors that influence the ther- apeutic effect of IL. The overall results showed that there was no significant difference in implant failure or MBL between IL and non-IL, and the sub- group analyses showed similar results to those of the overall analyses. These findings indicate that IL is a predictable and reliable treatment protocol for single-implant restorations over long- term follow-up. All studies included in the analysis had strict inclusion criteria for patient selection, such as good clinical health, non-smoking status, a minimum bone height of 10–12 mm, a minimum bone width of 5–6 mm, at least 5 mm of keratinized gingiva crestal,1,44,46,48 and missing teeth with adjacent natural teeth.13,47 Patients with an active in- fection or periodontal disease at the sites intended for implant placement, as well as those with chronic systemic diseases or poor oral hygiene, were ex- cluded.43,45,49,50 These strict inclusion criteria indicate that IL is a procedure with high technique sensitivity; hence more clinical trials are needed to ex- pand on its indication and application in intractable cases. Most of the in- cluded studies considered an insertion torque of 30–35 N∙cm to be acceptable, because adequate primary stability usually means better loading tolerance and thus is regarded as an important condition to be satisfied when IL is to be used.1,43,44,46,47,49 In the subgroup analyses for MBL, only the subgroup analyses by mand- ible implant location, implant place- ment time of delayed implant insertion, screw-retained prosthesis retention, and loading concept of non-occlusal contact did not present high heterogeneity, in- dicating that these factors may affect the final prognosis. The difference in heterogeneity between the subgroups of implant location – maxilla or mandible – may be due to the difference in bone quality between the maxilla and mandible. The higher bone density of the mandible could lead to less bone remodelling and higher primary im- plant stability. Regarding the type of prosthesis retention, the provisional restoration can be screw-retained or cement-retained. When the provisional restoration is cemented, there is a higher risk of gingival inflammation at the abutment–cement–restoration in- terface, as well as cement debonding.51 A recent review suggested that screw- retained single-implant restorations have several advantages over cement- retained restorations, including better clinical outcomes, more predictable re- tention and retrievability, fewer biolo- gical consequences associated with residual cement, and a simpler re- storative process.52 Regarding the loading protocol, immediate restora- tion without occlusal contact achieves a significantly higher implant survival Fig. 4. Forest plot for implant failure at the patient level. IL: immediate loading; EL: early loading; CL: conventional loading. Fig. 5. Forest plot for implant failure at the implant level. IL: immediate loading; EL: early loading; CL: conventional loading. 1350 Zhao et al. T ab le 2 . Su bg ro up a na ly se s. In de xe s Su bg ro up s N um be r of s tu di es T es t fo r ov er al l ef fe ct T es t fo r he te ro ge ne it y R R /M D ( 95 % C I) I2 P -v al ue Im pl an t fa ilu re ba se d on p at ie nt s Im pl an t lo ca ti on M ax ill a 6 0. 69 0% 0. 63 1. 36 ( 0. 30 , 6. 09 ) M an di bl e 1 N A N A N A N ot e st im ab le Im pl an t pl ac em en t ti m e Im m ed ia te 3 0. 74 0% 0. 73 0. 74 ( 0. 13 , 4. 31 ) D el ay ed 6 0. 37 0% 0. 94 2. 77 ( 0. 30 , 25 .5 9) T yp e of p ro st he si s re te nt io n Sc re w -r et ai ne d 5 0. 65 0% 0. 68 1. 60 ( 0. 21 , 11 .9 9) C em en t- re ta in ed 3 0. 64 0% N A 0. 57 ( 0. 06 , 5. 99 ) L oa di ng c on ce pt O cclu sa l co nt ac t 2 0. 96 N A N A 1. 07 ( 0. 07 , 16 .3 1) N on -o cc lu sa l co nt ac t 5 0. 37 0% 0. 94 2. 77 ( 0. 30 , 25 .5 9) P ro to co l fo r no n- im m ed ia te l oa di ng IL v s E L 1 0. 96 N A N A 1. 07 ( 0. 07 , 16 .3 1) IL v s C L 8 0. 69 0% 0. 63 1. 36 ( 0. 30 , 6. 09 ) Im pl an t fa ilu re ba se d on i m pl an ts Im pl an t lo ca ti on M ax ill a 6 0. 69 0% 0. 63 1. 36 ( 0. 30 , 6. 09 ) M an di bl e 2 1. 00 N A N A 1. 00 ( 0. 15 , 6. 87 ) Im pl an t pl ac em en t ti m e Im m ed ia te 4 0. 81 0% 0. 92 0. 85 ( 0. 23 , 3. 10 ) D el ay ed 6 0. 37 0% 0. 94 2. 77 ( 0. 30 , 25 .5 9) T yp e of p ro st he si s re te nt io n Sc re w -r et ai ne d 5 0. 65 0% 0. 86 1. 60 ( 0. 21 , 11 .9 9) C em en t- re ta in ed 4 0. 76 0% 0. 72 0. 79 ( 0. 18 , 3. 47 ) L oa di ng c on ce pt O cc lu sa l co nt ac t 3 0. 98 0% 0. 97 1. 02 ( 0. 21 , 4. 93 ) N on -o cc lu sa l co nt ac t 5 0. 37 0% 0. 94 2. 77 ( 0. 30 , 25 .5 9) P ro to co l fo r no n- im m ed ia te l oa di ng IL v s E L 1 0. 96 N A N A 1. 07 ( 0. 07 , 16 .3 1) IL v s C L 9 0. 75 0% 0. 81 1. 21 ( 0. 37 , 3. 95 ) M B L Im pl an t lo ca ti on M ax ill a 6 0. 73 60 % 0. 03 0. 03 ( − 0. 15 , 0. 22 ) M an di bl e 2 0. 06 44 % 0. 18 − 0. 25 ( − 0. 81 , 0. 01 ) Im pl an t pl ac em en t ti m e Im m ed ia te 4 0. 28 72 % 0. 01 − 0. 10 ( − 0. 28 , 0. 08 ) D el ay ed 6 0. 54 0% 0. 52 0. 02 ( − 0. 11 , 0. 15 ) T yp e of p ro st he si s re te nt io n Sc re w -r et ai ne d 5 0. 37 3% 0. 39 0. 04 ( − 0. 10 , 0. 18 ) C em en t- re ta in ed 4 0. 11 58 % 0. 07 − 0. 13 ( − 0. 29 , 0. 03 ) L oa di ng c on ce pt O cc lu sa l co nt ac t 3 0. 73 79 % 0. 01 − 0. 05 ( − 0. 33 , 0. 23 ) N on -o cc lu sa l co nt ac t 5 0. 52 3% 0. 39 0. 04 ( − 0. 13 , 0. 21 ) P ro to co l fo r no n- im m ed ia te l oa di ng IL v s E L 1 0. 53 N A N A 0. 0 6 (− 0. 13 , 0. 25 ) IL v s C L 9 0. 43 53 % 0. 03 − 0. 05 ( − 0. 18 , 0. 08 ) R R , ri sk r at io ; M D , m ea n di ff er en ce ; C I, c on fid en ce i nt er va l; N A , no t ap pl ic ab le ; IL , im m ed ia te l oa di ng ; E L , ea rl y lo ad in g; C L , co nv en ti on al l oa di ng ; M B L , m ar gi na l bo ne l os s. Immediate vs non-immediate single implant loading 1351 rate compared to restoration with oc- clusal contact,23 since there is reduced interference with osseointegration of the implant. Therefore, it is concluded that the screw-retained type of pros- thesis retention, a mandible location, and non-occlusal contact may be ben- eficial and enhance the prognosis of IL in single-implant restorations. How- ever, more clinical trials are needed to confirm the effects of these factors. Some of the included studies com- bined immediate implant placement with IL43,45,47,49 to reduce the treatment period and replace the damaged tooth immediately. Recent clinical studies and reviews have suggested that IL of immediate dental implants is a reliable treatment option for dental rehabilita- tion,28,53,54 but others have argued that immediate implants may be at higher risk of implant failure than delayed implants.15 In the present study, the analysis of MBL for IL versus non-IL showed high heterogeneity, while the heterogeneity in the subgroup analysis for MBL according to a delayed im- plant placement time was not sig- nificant. Therefore, it seems that IL has a more predictable prognosis when combined with delayed implant place- ment than immediate implant place- ment. Clinical studies have suggested that most of the reduction in alveolar bone mass after the extraction of nat- ural teeth occurs within the first 6 months to 2 years.12 This indicates that unpredictable MBL in IL of an im- mediately placed implant might occur due to post-extraction bone remodel- ling of the alveolar bone, so the influ- ence of IL is still controversial. This study has some advantages when compared to previous meta-ana- lyses.15,20,38–40,55 First, this study ana- lysed the long-term follow-up clinical outcomes of IL compared with non-IL, including EL and CL, in single-implant restorations. Second, subgroup ana- lyses were performed to further in- vestigate factors influencing the final prognosis, including the type of non-IL (EL or CL), implant location (mandible or maxilla), implant placement time (immediate implant placement or de- layed implant placement), loading concept (occlusal or non-occlusal con- tact), and type of prosthesis retention (screw-retained or cement-retained). The controversy regarding the long- term effects of IL as reported in pre- vious studies may have been caused by the factors mentioned above. For ex- ample, according to this meta-analysis, better outcomes a more likely to be achieved with a screw-retained pros- thesis, for implants located in the mandible, and for implants with non- occlusal contact. The main limitation of this study was the inability to perform all of the sub- group analyses due to small sample sizes. Although multiple databases were searched, the number of included stu- dies was still small, and for some cases, such as implant failure, there was rela- tively low power to show any differ- ences between IL and EL/CL for these outcomes. Thus, more clinical trials are still needed to investigate the effects of these factors on the prognosis of IL. In conclusion, IL shows predictable and reliable clinical outcomes at long- term follow-up when applied to single- implant restorations in carefully selected cases. An insertion torque of 30–35 N∙cm is acceptable for the use of IL for a single implant. A screw-retained prosthesis re- tention type, implant location in the mandible, and implant with non-occlusal contact may be important to ensure the prognosis of IL of a single implant. Funding This study was supported by the National Natural Science Foundation of China (No. 81771107); the School of Stomatology, Fourth Military Medical University. The funding of this study supported the analysis, interpretation of the data, and the decision to submit the article for publication. Ethical approval Not required. Patient consent Not required. Data availability The data used to support the findings of this study are available from the corresponding author upon request. Acknowledgements. The authors thank Wei Ma, Chao Xie, and Yan Liu for their contributions and valuable assis- tance in the research. Competing interests None. Appendix A. Supporting information Supplementary data associated with this article can be found in the online version at doi:10.1016/j.ijom.2022. 03.057. Fig. 6. Forest plot for marginal bone loss. IL: immediate loading; EL: early loading; CL: conventional loading. 1352 Zhao et al. References 1. Donos N, Horvath A, Calciolari E, Mardas N. Immediate provisionalization of bone level implants with a hydrophilic surface. A five-year follow-up of a ran- domized controlled clinical trial. Clin Oral Implants Res 2019;30:139–49. 2. Yildiz P, Zortuk M, Kilic E, Dincel M, Albayrak H. Clinical outcomes after im- mediate and late implant loading for a single missing tooth in the anterior max- illa. Implant Dent 2016;25:504–9. 3. Weigl P, Strangio A. The impact of im- mediatelyplaced and restored single- tooth implants on hard and soft tissues in the anterior maxilla. Eur J Oral Implantol 2016;9:S89–106. 4. Atieh MA, Duncan WJ, Faggion Jr. CM. Quality assessment of systematic reviews on oral implants placed immediately into fresh extraction sockets. Int J Oral Maxillofac Implants 2016;31:338–51. 5. Zarrabi MJ, Radvar M, Shiezadeh F, Mokhtari MR, Nejat A. Immediate non- functional loading of a single implant in the posterior maxillary area: a rando- mized clinical trial. J Long Term Eff Med Implants 2018;28:145–53. 6. den Hartog L, Raghoebar GM, Stellingsma K, Vissink A, Meijer HJA. Immediate non-occlusal loading of single implants in the aesthetic zone: a rando- mized clinical trial. J Clin Periodontol 2011;38:186–94. 7. Zembic A, Glauser R, Khraisat A, Haemmerle CHF. Immediate vs. early loading of dental implants: 3-year results of a randomized controlled clinical trial. Clin Oral Implants Res 2010;21:481–9. 8. Mitsias M, Siormpas K, Pistilli V, Trullenque-Eriksson A, Esposito M. Immediate, early (6 weeks) and delayed loading (3 months) of single, partial and full fixed implant supported prostheses: 1- year post-loading data from a multicentre randomised controlled trial. Eur J Oral Implantol 2018: 11: 63–75. 9. Raes S, Raes F, Cooper L, Tarrida L, Vervaeke S, Cosyn J, De Bruyn H. Oral health-related quality of life changes after placement of immediately loaded single implants in healed alveolar ridges or ex- traction sockets: a 5-year prospective follow-up study. Clin Oral Implants Res 2017;28:662–7. 10. Schropp L, Isidor F. Papilla dimension and soft tissue level after early vs. delayed placement of single-tooth implants: 10- year results from a randomized con- trolled clinical trial. Clin Oral Implants Res 2015;26:278–86. 11. Schincaglia GP, Marzola R, Giovanni GF, Chiara CS, Scotti R. Replacement of mandibular molars with single-unit re- storations supported by wide-body im- plants: immediate versus delayed loading. A randomized controlled study. Int J Oral Maxillofac Implants 2008;23:474–80. 12. Mangano FG, Mastrangelo P, Luongo F, Blay A, Tunchel S, Mangano C. Aesthetic outcome of immediately re- stored single implants placed in extrac- tion sockets and healed sites of the anterior maxilla: a retrospective study on 103 patients with 3 years of follow-up. Clin Oral Implants Res 2017;28:272–82. 13. den Hartog L, Raghoebar GM, Stellingsma K, Vissink A, Meijer HJ. Immediate loading of anterior single tooth implants placed in healed sites: five- year results of a randomized clinical trial. Int J Prosthodont 2016;29:584–91. 14. Grandi T, Guazzi P, Samarani R, Tohme H, Khoury S, Sbricoli L, Grandi G, Esposito M. Immediate, early (3 weeks) and conventional loading (4 months) of single implants: preliminary data at 1 year after loading from a pragmatic multicenter randomised controlled trial. Eur J Oral Implantol 2015;8:115–26. 15. Pigozzo MN, da Costa TR, Sesma N, Lagana DC. Immediate versus early loading of single dental implants: a sys- tematic review and meta-analysis. J Prosthet Dent 2018;120:25–34. 16. Yildiz P, Zortuk M, Kilic E, Dincel M, Albayrak H. Esthetic outcomes after im- mediate and late implant loading for a single missing tooth in the anterior max- illa. Niger J Clin Pract 2018;21:1164–70. 17. Blaszczyszyn A, Heinemann F, Gedrange T, Kawala B, Gerber H, Dominiak M. Immediate loading of an implant with fine threaded neck-bone resorption and clinical outcome of single tooth restora- tions in the maxilla. Biomed Tech (Berl) 2012;57:3–9. 18. Chan HL, George F, Wang IC, del Amo FSL, Kinney J, Wang HL. A randomized controlled trial to compare aesthetic outcomes of immediately placed implants with and without immediate provisiona- lization. J Clin Periodontol 2019; 46:1061–9. 19. Rieder D, Eggert J, Krafft T, Weber HP, Wichmann MG, Heckmann SM. Impact of placement and restoration timing on single-implant esthetic outcome—a ran- domized clinical trial. Clin Oral Implants Res 2016;27:E80–6. 20. Huynh-Ba G, Oates TW, Williams MAH. Immediate loading vs. early/con- ventional loading of immediately placed implants in partially edentulous patients from the patients’ perspective: a sys- tematic review. Clin Oral Implants Res 2018;29:255–69. 21. Dard M, Shiota M, Sanda M, Yajima Y, Sekine H, Kasugai S. A randomized, 12- month controlled trial to evaluate non- inferiority of early compared to conven- tional loading of modSLA implants in single tooth gaps. Int J Implant Dent 2016;2:10. 22. Brignardello-Petersen R. Small trial sug- gests that patients receiving a single im- plant-supported crown in the anterior maxilla who receive provisional crowns have better soft-tissue esthetic outcomes than do those who do not. J Am Dent Assoc 2019;150:E218. 23. Kolerman R, Tal H, Guirado JC, Barnea E, Chaushu L, Abu Wasel M, Nissan J. Aesthetics and survival of immediately restored implants in partially edentulous anterior maxillary patients. Appl Sci 2018;8:377. 24. Arora H, Ivanovski S. Clinical and aes- thetic outcomes of immediately placed single-tooth implants with immediate vs. delayed restoration in the anterior max- illa: a retrospective cohort study. Clin Oral Implants Res 2018;29:346–52. 25. Raes S, Eghbali A, Chappuis V, Raes F, De Bruyn H, Cosyn J. A long-term pro- spective cohort study on immediately re- stored single tooth implants inserted in extraction sockets and healed ridges: CBCT analyses, soft tissue alterations, aesthetic ratings, and patient-reported outcomes. Clin Implant Dent Relat Res 2018;20:522–30. 26. Gjelvold B, Kisch J, Chrcanovic BR, Albrektsson T, Wennerberg A. Clinical and radiographic outcome following im- mediate loading and delayed loading of single-tooth implants: randomized clin- ical trial. Clin Implant Dent Relat Res 2017;19:549–58. 27. Oh TJ, Shotwell JL, Billy EJ, Wang HL. Effect of flapless implant surgery on soft tissue profile: a randomized controlled clinical trial. J Periodontol 2006; 77:874–82. 28. Crespi R, Fabris GBM, Crespi G, Toti P, Marconcini S, Covani U. Effects of dif- ferent loading protocols on the bone re- modeling volume of immediate maxillary single implants: a 2- to 3-year follow-up. Int J Oral Maxillofac Implants 2019; 34:953–62. 29. Akoglan M, Tatli U, Kurtoglu C, Salimov F, Kurkcu M. Effects of dif- ferent loading protocols on the secondary stability and peri-implant bone density of the single implants in the posterior max- illa. Clin Implant Dent Relat Res 2017; 19:624–31. 30. Zoellner A, Ganeles J, Korostoff J, Guerra F, Krafft T, Braegger U. Immediate and early non-occlusal loading of Straumann implants with a chemically modified surface (SLActive) in the posterior mandible and maxilla: in- terim results from a prospective multi- center randomized-controlled study. Clin Oral Implants Res 2008;19:442–50. 31. Donati M, La Scala V, Billi M, Di Dino B, Torrisi P, Berglundh T. Immediate Immediate vs non-immediate single implant loading 1353 functional loading of implants in single tooth replacement: a prospective clinical multicenter study. Clin Oral Implants Res 2008;19:740–8. 32. Stacchi C, Lombardi T, Baldi D, Bugea C, Rapani A, Perinetti G, Itri A, Carpita D, Audenino G, Bianco G, Verardi S, Carossa S, Schierano G. Immediate loading of implant-supported single crowns after conventional and ultrasonic implant site preparation: a multicenter randomized controlled clinical trial. Biomed Res Int 2018;2018:6817154. 33. Daher FI, Abi-Aad HL, Dimassi HI, Cordioli G, Majzoub ZAK. Immediate versus conventional loading of variable- thread tapered implants supporting three- to four-unit fixed partial dentures in the posterior maxilla: 3-year results of a split- mouth randomised controlled trial. Int J Oral Implantol 2019;12:449–66. 34. Hall JAG, Payne AGT, Purton DG, Torr B, Duncan WJ, De, Silva RK. Immediately restored,single-tapered im- plants in the anterior maxilla: prostho- dontic and aesthetic outcomes after 1 year. Clin Implant Dent Relat Res 2007; 9:34–45. 35. Barewal RM, Stanford C, Weesner TC. A randomized controlled clinical trial com- paring the effects of three loading proto- cols on dental implant stability. Int J Oral Maxillofac Implants 2012;27:945–56. 36. Block MS, Mercante DE, Lirette D, Mohamed W, Ryser M, Castellon P. Prospective evaluation of immediate and delayed provisional single tooth restora- tions. J Oral Maxillofac Surg 2009; 67:89–107. 37. Donati M, Botticelli D, La Scala V, Tomasi C, Berglundh T. Effect of im- mediate functional loading on osseointe- gration of implants used for single tooth replacement. A human histological study. Clin Oral Implants Res 2013;24:738–45. 38. Zhang S, Wang S, Song Y. Immediate loading for implant restoration compared with early or conventional loading: a meta-analysis. J Craniomaxillofac Surg 2017;45:793–803. 39. Chrcanovic BR, Albrektsson T, Wennerberg A. Immediately loaded non- submerged versus delayed loaded sub- merged dental implants: a meta-analysis. Int J Oral Maxillofac Surg 2015; 44:493–506. 40. Del Fabbro M, Testori T, Kekovic V, Goker F, Tumedei M, Wang HL. A sys- tematic review of survival rates of os- seointegrated implants in fully and partially edentulous patients following immediate loading. J Clin Med 2019; 8:2142. 41. Page MJ, McKenzie JE, Bossuyt PM, Boutron I, Hoffmann TC, Mulrow CD, Shamseer L, Tetzlaff JM, Akl EA, Brennan SE, Chou R, Glanville J, Grimshaw JM, Hrobjartsson A, Lalu MM, Li T, Loder EW, Mayo-Wilson E, McDonald S, McGuinness LA, Stewart LA, Thomas J, Tricco AC, Welch VA, Whiting P, Moher D. The PRISMA 2020 statement: an updated guideline for re- porting systematic reviews. Int J Surg 2021;88:105906. 42. Higgins JP, Altman DG, Gotzsche PC, Juni P, Moher D, Oxman AD, Savovic J, Schulz KF, Weeks L, Sterne JA. Cochrane Statistical Methods Group. The Cochrane Collaboration’s tool for assessing risk of bias in randomised trials Cochrane Bias Methods Group BMJ 2011;343:d5928. 43. Shibly O, Patel N, Albandar JM, Kutkut A. Bone regeneration around implants in periodontally compromised patients: a randomized clinical trial of the effect of immediate implant with immediate loading. J Periodontol 2010;81:1743–51. 44. Bömicke W, Gabbert O, Koob A, Krisam J, Rammelsberg P. Comparison of immediately loaded flapless-placed one-piece implants and flapped-placed conventionally loaded two-piece im- plants, both fitted with all-ceramic single crowns, in the posterior mandible: 3-year results from a randomised controlled pilot trial. Eur J Oral Implantol 2017; 10:179–95. 45. Prosper L, Crespi R, Valenti E, Cappare P, Gherlone E. Five-year follow-up of wide-diameter implants placed in fresh molar extraction sockets in the mandible: immediate versus delayed loading. Int J Oral Maxillofac Implants 2010;25:607–12. 46. Meloni SM, Baldoni E, Duvina M, Pisano M, De Riu G, Tallarico M. Immediate non-occlusal versus delayed loading of mandibular first molars. Five- year results from a randomised controlled trial. Eur J Oral Implantol 2018; 11:409–18. 47. Crespi R, Cappare P, Gherlone E, Romanos GE. Immediate versus delayed loading of dental implants placed in fresh extraction sockets in the maxillary es- thetic zone: a clinical comparative study. Int J Oral Maxillofac Implants 2008; 23:753–8. 48. Chidagam PRLV, Gande VC, Yadlapalli S, Venkata RY, Kondaka S, Chedalawada S. Immediate versus delayed loading of implant for replace- ment of missing mandibular first molar: a randomized prospective six years clinical study. J Clin Diagn Res 2017;11:ZC35–9. 49. Cannizzaro G, Felice P, Leone M, Ferri V, Viola P, Esposito M. Immediate versus early loading of 6.5 mm-long flapless-placed single implants: a 4-year after loading report of a split-mouth randomised controlled trial. Eur J Oral Implantol 2012;5:111–21. 50. Degidi M, Nardi D, Piattelli A. Immediate versus one-stage restoration of small-diameter implants for a single missing maxillary lateral incisor: a 3-year randomized clinical trial. J Periodontol 2009;80:1393–8. 51. Ladino LG, Rosselli D. Use of extracted anterior teeth as provisional restorations and surgical guide for immediate multiple implant placement: a clinical case report. J Esthet Restor Dent 2019;31:209–12. 52. Priest G. A current perspective on screw- retained single-implant restorations: a review of pertinent literature. J Esthet Restor Dent 2017;29:161–71. 53. Henningsen A, Smeets R, Koppen K, Sehner S, Kornmann F, Grobe A, Heiland M, Gerlach T. Immediate loading of subcrestally placed dental im- plants in anterior and premolar sites. J Craniomaxillofac Surg 2017;45:1898–905. 54. Malchiodi L, Balzani L, Cucchi A, Ghensi P, Nocini PF. Primary and sec- ondary stability of implants in post- extraction and healed sites: a randomized controlled clinical trial. Int J Oral Maxillofac Implants 2016;31:1435–43. 55. Chen J, Cai M, Yang J, Aldhohrah T, Wang Y. Immediate versus early or con- ventional loading dental implants with fixed prostheses: a systematic review and meta-analysis of randomized controlled clinical trials. J Prosthet Dent 2019; 122:516–36. Correspondence to: State Key Laboratory of Military Stomatology and National Clinical Research Center for Oral Diseases and Shaanxi Engineering Research Center for Dental Materials and Advanced Manufacture Department of Oral implantology School of Stomatology The Fourth Military Medical University Shaanxi 710032 PR China. Tel:+86 029 84776454. E-mail: songyingliang@163.com 1354 Zhao et al. Long-term clinical outcomes of immediate loading versus non-immediate loading in single-implant restorations: a systematic r... Materials and methods Search strategy Screening of records and assessment of eligibility Data extraction Quality assessment Statistical analysis Results Study selection Characteristics of the included studies Meta-analyses for implant failure Meta-analysis for marginal bone loss (MBL) Publication bias and assessment of the quality of evidence Discussion Funding Ethical approval Patient consent Data availability Acknowledgements Competing interests Appendix A. Supporting information References